Inspections for the day of: Wednesday, July 6, 2011.
Number of inspections: 18
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorDaryl DeGrange
TitleELE-INSPECTION SUPV
Phone #794-1379
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE11-01451 Final7/6/20117/6/20117/6/2011 3:53:05 PMPPASS
Phone #: ###-#### >> Inspection requested via web by daniel bibikov final ok UL listed solar panels & SA listed inverters
ELE11-01456 Final7/6/20117/6/20117/6/2011 3:51:44 PMPPASS
Phone #: ###-#### >> Inspection requested via web by daniel bibikov final ok UL isted solar panels & SA listed inverters
ELE11-01452 Final7/6/20117/6/20117/6/2011 3:46:16 PMPPASS
Phone #: ###-#### >> Inspection requested via web by daniel bibikov final ok UL listed solar panels & SA listed inverters
ELE11-01453 Final7/6/20117/6/20117/6/2011 3:45:15 PMPPASS
Phone #: ###-#### >> Inspection requested via web by daniel bibikov final ok UL listed solar panels & SA listed inverters
ELE11-01454 Final7/6/20117/6/20117/6/2011 3:44:04 PMPPASS
Phone #: ###-#### >> Inspection requested via web by daniel bibikov final ok UL listed solar panels & SA listed inverters
ELE11-01450 Temporary Service7/6/20117/6/20117/6/2011 3:18:55 PMPFAIL
Phone #: ###-#### >> Inspection requested via web by daniel bibikov NEC 250.64(E) Shall use metallic connector listed for grounding & bonding or use non-metallic connector where electrode conductor enters service equipment.
ELE11-01449 Temporary Service7/6/20117/6/20117/6/2011 3:14:36 PMPFAIL
Phone #: ###-#### >> Inspection requested via web by daniel bibikov NEC 250.64(E) Shall use metallic connector listed for grounding & bonding or use non-metallic connector where electrode conductor enters service equipment.
ELE10-02116 Conference7/5/20117/6/20117/6/2011 2:44:51 PMPDONE
Al-Please call prior to inspection Phone #: ###-#### circuitry,wire ampacity,stapling, box fill,receptacle spacing,UL listings, aproved ceiling fan boxes,1 1/4 from edge of framing member,nail plates
ELE11-01359 Electrical Rough-In7/6/20117/6/20117/6/2011 1:23:59 PMPNH
KEITH - please call for access Phone #: ###-####
ELE11-01074 Final7/6/20117/6/20117/6/2011 1:01:33 PMPPASS
Phone #: ###-#### >> Inspection requested via web by mike brown final ok
ELE10-02514 Final7/6/20117/6/20117/6/2011 12:38:09 PMAPASS
mike Phone #: ###-#### final ok
ELE10-01190 Final7/5/20117/6/20117/6/2011 11:03:25 AMAPASS
Ivan Phone #: 331- final ok
ELE11-00330 Final7/5/20117/6/20117/6/2011 10:34:51 AMAPASS
michael Phone #: ###-#### final ok
ELE10-02132 Electrical Rough-In7/5/20117/6/20117/6/2011 10:14:53 AMAPASS
call with questions ###-#### Phone #: ###-#### >> Inspection requested via web by Don Conley rough-in ok, main floor only
ELE11-01253 Final7/6/20117/6/20117/6/2011 9:21:13 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Tim Dunlop final ok
ELE11-01332 Permanent Service7/6/20117/6/20117/6/2011 8:48:30 AMAFAIL
There hasnt been a meter at this home for over a year, IP is requiring an insp of the service before powering, Access code is 2609, thanks, TW. Phone #: ###-#### >> Inspection requested via web by Stephen Kren NEC 250-64 Need two grounding electrodes 6 feet apart. Waterpipe bonding conductor shall have listed grounding connector or non-metal connector where conductor enters panel. staple romex above panel. NEC 408-4 shall provide circuit directory for final.
ELE11-01332 Final7/5/20117/6/20117/6/2011 7:27:37 AMACANC
There hasnt been a meter at this home for over a year, IP is requiring an insp of the service before powering, thx. Phone #: ###-#### >> Inspection requested via web by Stephen Kren Inspection cancelled from web by: Stephen Kren
ELE11-01311 Final7/5/20117/6/20117/5/2011 3:26:44 PMAPASS
Phone #: ###-#### >> Inspection requested via web by Dan Rohl final ok