Inspections for the day of: Friday, July 6, 2018.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Reynolds
TitleMEC INSPECTOR
Phone #208-803-2395
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC18-03173 Final7/5/20187/6/20187/6/2018 4:30:52 PMPNR
please call our lead installer Johnny when 30 mins in route. Later afternoon would be preferred if possible, 3-5p Phone #: ###-#### Inspection requested via web by Rick Montgomery
MEC18-03159 Final7/6/20187/6/20187/6/2018 2:11:11 PMPFAIL
Geff---for furnace in the attick Phone #: ###-####- need to support lineset at outdoor unit
MEC18-03212 Rough-in7/6/20187/6/20187/6/2018 2:10:43 PMPFAIL
Bob Phone #: ###-#### Inspection requested via web by Sheldon Lebow- need an attic insulation sheild around flue pipe to be able to maintain 1" clearances with insulation - also want to see what roof flashing is going to be used for flue pipe and if it will maintain the 1" clearances around flue.
MEC18-03151 Pressure Test7/5/20187/6/20187/6/2018 2:07:12 PMPPASS
If questions contact Jerry Prough @ ###-####. Phone #: ###-#### Inspection requested via web by Stacia Haumann- 20 lb gas pressure test ok
MEC18-03190 Rough-in7/5/20187/6/20187/6/2018 1:07:43 PMPPART
Cover Inspection call Scott for access Phone #: ###-#### Inspection requested via web by Brandon Sorensen- all duct work above hardlid ceiling ok duct seal ok- looks like eletrical installers still need a tstat location put in- when finished with the rest of the duct work in the open space call for a full R/I
MEC17-00806 Final7/2/20187/6/20187/6/2018 12:12:53 PMPPART
Please call Jake at ###-#### when you are on your way. Thanks! Phone #: ###-#### Inspection requested via web by Angie Pereira- air balance ok- duct blast ok- flue clearances ok just need to finish trim ring at ceiling- secoundary drain with wet switch ok- need to see exhaust fans finished- looks like a kitchen cabinet still needs to be in place so a supply run can be finished make sure its ducted all the way out of cabinet- also want to know whats happening with the fireplace before a final can be done
MEC18-02883 Final7/5/20187/6/20187/6/2018 11:25:11 AMAPASS
Please call Bonnie when on the way. ###-#### Thank you! Phone #: ###-#### Inspection requested via web by Rick Borg- A/C coil co ok
MEC18-02612 Rough-in7/5/20187/6/20187/6/2018 11:12:01 AMAPART
Please call homeowner 30 minutes in advance for access at ###-#### and call Ryan with any questions at ###-####. Thank you Phone #: ###-#### Inspection requested via web by Lea Briggs- furnace coil installed R/I ok- still need to see missing supply run by back door- owner says that kitcken supply run might have to move so i want to see those changes if they are made- need to also insulate the rest of the supply and return trunk lines in hallway( IECC C403.2.9 duct and plenum insulation and sealing) trunk lines are in an unconditioned space so they need to be insulated
MEC17-04148 Rough-in7/5/20187/6/20187/6/2018 10:25:39 AMAPART
Contact Rich Beckstead ###-#### Phone #: ###-#### Inspection requested via web by Beka Hereau- phase 2 new addtion on west side duct seal ok ready for insulation,truck bay exhaust and make-up air duct ok- centeral location of building/kitcken exhaust through roof ok duct seal ok ready for insulation- talked with plumber about pressure tests he said he will get hydronics, gasline, and air on pressure and call in all at once
MEC18-01559 Final7/5/20187/6/20187/6/2018 9:34:30 AMAPART
duct blast witness at 9 am. thanks Phone #: ###-#### Inspection requested via web by Gary Reeves- ductblast ok- job still needs work finished for full final
MEC18-01705 Final7/5/20187/6/20187/6/2018 8:55:55 AMAPASS
Phone #: ###-#### Inspection requested via web by Melissa Skinner- rtu 5 fresh air intake 10' away from vent ok- rtu2 fresh air intake 10' away from vent ok- final ok
MEC17-02054 Mec-Aging Inspection7/6/20187/6/20187/6/2018 8:47:57 AM DONE
called HVAC company to contact homeowner and schedule inspection on ac change out