ELE07-03835
| Final | 7/7/2008 | 7/7/2008 | 7/7/2008 4:50:01 PM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 7/7/2008 at 7:34:54 AM. Contact: ###-####. ok to final, no esc this project
|
ELE07-03040
| Final | 7/7/2008 | 7/7/2008 | 7/7/2008 3:49:50 PM | P | PASS |
|
|
Joe Phone #: ###-#### called contractor, ok to final
|
ELE08-01825
| Final | 7/7/2008 | 7/7/2008 | 7/7/2008 3:13:46 PM | P | PASS |
|
|
ok to final, no esc this project
|
ESC06-01508
| General Inspection | 7/7/2008 | 7/7/2008 | 7/7/2008 3:12:33 PM | P | PASS |
|
|
looked ok
|
ESC07-01434
| General Inspection | 7/7/2008 | 7/7/2008 | 7/7/2008 3:11:18 PM | A | PASS |
|
|
looked ok
|
ESC08-00246
| General Inspection | 7/7/2008 | 7/7/2008 | 7/7/2008 3:10:15 PM | A | PASS |
|
|
looked ok
|
ELE08-00768
| Permanent Service | 7/7/2008 | 7/7/2008 | 7/7/2008 2:58:33 PM | P | FAIL |
|
|
Phone #: ###-#### Internet Inspection Request from: Lee VanSchoiack called contractor, left correction notice, NEC 110.3(A) contactor shall be listed by a nationally recognized testing lab, shall not use romex connector for gec abrasion protection, 352.30(A) rnc shall be securely fastened within 3' of panel, BCC shall verify with ipco that less than 10000 amps available for fault current level, no esc this project
|
ELE08-01841
| Permanent Service | 7/6/2008 | 7/7/2008 | 7/7/2008 12:58:06 PM | P | PASS |
|
|
Ok for Id Power to re-connect. Randy ###-#### Phone #: ###-#### Internet Inspection Request from: Randy Fletcher p/s o/h rec ok, no esc this project
|
ELE08-00364
| Electrical Rough-In | 7/3/2008 | 7/7/2008 | 7/7/2008 10:10:12 AM | A | PASS |
|
|
Please inspect floor heat in the main hall off the entry. Thanks Phone #: ###-#### Internet Inspection Request from: ERIC CENTERS floor heat in hall only ok to cover
|
ELE08-01840
| Electrical Rough-In | 7/3/2008 | 7/7/2008 | 7/7/2008 9:38:32 AM | A | PASS |
|
|
Bonding inspection ###-#### Internet Inspection Request from: Todd Holbrook pool and hot tub bonding only ok, no esc this project
|
ELE08-01825
| Electrical Rough-In | 7/7/2008 | 7/7/2008 | 7/7/2008 9:00:56 AM | A | PASS |
|
|
ready Phone #: ###-#### Internet Inspection Request from: gary batten ric ok for u/g, see final, no esc this project
|
ELE08-01344
| Final | 7/3/2008 | 7/7/2008 | 7/7/2008 8:34:58 AM | A | FAIL |
|
|
contact: Leon Sheffield Phone #: ###-#### Internet Inspection Request from: Deb Gooden called, left message, ground rods ok, no power to check, NEC 410.15(B) shall provide raintight handholes at poles, 408.4 shall complete circuit directory, 230.24 gec and grounded conductor shall be connected
|
ELE08-01761
| Electrical Rough-In | 7/7/2008 | 7/7/2008 | 7/7/2008 12:00:00 AM | P | CANC |
|
|
cecily Phone #: ###-####
|