Inspections for the day of: Monday, July 7, 2008.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE07-03835 Final7/7/20087/7/20087/7/2008 4:50:01 PMPPASS
Scheduled by a contractor via Hello! on 7/7/2008 at 7:34:54 AM. Contact: ###-####. ok to final, no esc this project
ELE07-03040 Final7/7/20087/7/20087/7/2008 3:49:50 PMPPASS
Joe Phone #: ###-#### called contractor, ok to final
ELE08-01825 Final7/7/20087/7/20087/7/2008 3:13:46 PMPPASS
ok to final, no esc this project
ESC06-01508 General Inspection7/7/20087/7/20087/7/2008 3:12:33 PMPPASS
looked ok
ESC07-01434 General Inspection7/7/20087/7/20087/7/2008 3:11:18 PMAPASS
looked ok
ESC08-00246 General Inspection7/7/20087/7/20087/7/2008 3:10:15 PMAPASS
looked ok
ELE08-00768 Permanent Service7/7/20087/7/20087/7/2008 2:58:33 PMPFAIL
Phone #: ###-#### Internet Inspection Request from: Lee VanSchoiack called contractor, left correction notice, NEC 110.3(A) contactor shall be listed by a nationally recognized testing lab, shall not use romex connector for gec abrasion protection, 352.30(A) rnc shall be securely fastened within 3' of panel, BCC shall verify with ipco that less than 10000 amps available for fault current level, no esc this project
ELE08-01841 Permanent Service7/6/20087/7/20087/7/2008 12:58:06 PMPPASS
Ok for Id Power to re-connect. Randy ###-#### Phone #: ###-#### Internet Inspection Request from: Randy Fletcher p/s o/h rec ok, no esc this project
ELE08-00364 Electrical Rough-In7/3/20087/7/20087/7/2008 10:10:12 AMAPASS
Please inspect floor heat in the main hall off the entry. Thanks Phone #: ###-#### Internet Inspection Request from: ERIC CENTERS floor heat in hall only ok to cover
ELE08-01840 Electrical Rough-In7/3/20087/7/20087/7/2008 9:38:32 AMAPASS
Bonding inspection ###-#### Internet Inspection Request from: Todd Holbrook pool and hot tub bonding only ok, no esc this project
ELE08-01825 Electrical Rough-In7/7/20087/7/20087/7/2008 9:00:56 AMAPASS
ready Phone #: ###-#### Internet Inspection Request from: gary batten ric ok for u/g, see final, no esc this project
ELE08-01344 Final7/3/20087/7/20087/7/2008 8:34:58 AMAFAIL
contact: Leon Sheffield Phone #: ###-#### Internet Inspection Request from: Deb Gooden called, left message, ground rods ok, no power to check, NEC 410.15(B) shall provide raintight handholes at poles, 408.4 shall complete circuit directory, 230.24 gec and grounded conductor shall be connected
ELE08-01761 Electrical Rough-In7/7/20087/7/20087/7/2008 12:00:00 AMPCANC
cecily Phone #: ###-####