Inspections for the day of: Tuesday, July 7, 2015.
Number of inspections: 17
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE15-01902 Final7/7/20157/7/20157/7/2015 3:33:18 PMPPASS
late pm Scott Phone #: ###-#### All electrical surface mounted. No card posted. Final ok
ELE15-02069 Conference7/7/20157/7/20157/7/2015 2:56:29 PMPDONE
This is a conference to meet at the Starbucks jobsite at Boise Town Square Mall to discuss the proximity of the new sink to the existing electrical panels. Please contact Jay Sprik, ###-####, to determine what time to meet. Phone #: ###-#### Inspection requested via web by Richard Montgomery
Discussed minimum distance from a panel to a sink.
Boise City Ordinance Section 4-05 31-SPECIAL CODE REQUIREMENTS
In addition to the provisions specified in this Section, the Director of the Planning &
Development Services Department may require other safeguards based on special conditions that may be present in a particular installation. These safeguards include but are not limited to the
following:
A. Disconnect and Panel Locations. Main Circuit disconnecting switches and/or
distribution panels shall not be installed in a bathroom, shower room, toilet room
or next to a washbasin, laundry tub, janitor's tub or other location thought unsafe
by the inspector. Minimum distance of 3' waters edge to bussing.
ELE15-02068 Final7/7/20157/7/20157/7/2015 2:18:40 PMPFAIL
Call 30 mins before // Tom Phone #: ###-#### 210.8(B)(7)- Receptacle outlets located in locker rooms with shower facilities shall have GFCI protection
ELE15-02067 Final7/7/20157/7/20157/7/2015 2:14:05 PMPPASS
Call 30 mins before // Tom Phone #: ###-#### Listing, and labelling, confirmed. Final ok
ELE15-02037 Permanent Service7/7/20157/7/20157/7/2015 1:25:28 PMPPASS
ok to cover // Dan Phone #: ###-#### Under ground conduit not connected to conduit below meter base. p/s u/g n ok
ELE15-02037 Electrical Rough-In7/7/20157/7/20157/7/2015 1:24:08 PMPPASS
ok to cover // Dan Phone #: ###-#### Rough in ok cover
ELE15-02064 Final7/7/20157/7/20157/7/2015 12:37:55 PMPFAIL
Please call for access Phone #: ###-#### Inspection requested via web by kendall bender See rough in
ELE15-02063 Final7/7/20157/7/20157/7/2015 12:37:33 PMPFAIL
Please call for access Phone #: ###-#### Inspection requested via web by kendall bender See rough in
ELE15-02063 Electrical Rough-In7/7/20157/7/20157/7/2015 12:37:02 PMPFAIL
Please call for access Phone #: ###-#### Inspection requested via web by kendall bender 250.53(A)(3)- Water piping system used for grounding electrode shall have supplemental rod.
334.12(B)(4)- NM cable shall not be install in a damp or wet location. Whip from disc to AC.
200.7(C)- If white conductor is used for other than grounded conductor it shall be re-identified other than white.
Verbal with contact
ELE15-02064 Electrical Rough-In7/7/20157/7/20157/7/2015 12:35:06 PMPFAIL
Please call for access Phone #: ###-#### Inspection requested via web by kendall bender 110.14- Dissimilar metals shall not be in physical contact with each other in connnector.
422.30- A disconnecting means shall be provided for furnace with in sight of unit.
Verbal with contact.
ELE15-01698 Final7/6/20157/7/20157/7/2015 11:14:28 AMACANC
Floor heat only please.... Inspection requested via web by Paula Gratiot needed rough in inspection
ELE15-01698 Electrical Rough-In7/7/20157/7/20157/7/2015 11:13:37 AMPPASS
Floor heat only please.... Inspection requested via web by Paula Gratiot floor heat rough in ok cover
ELE15-01990 Electrical Rough-In7/6/20157/7/20157/7/2015 10:50:18 AMAPASS
Matt Phone #: ###-#### Addition above garage rough in ok cover
ELE15-01292 Electrical Rough-In7/6/20157/7/20157/7/2015 10:32:52 AMAFAIL
would like call ahead; Jason Phone #: ###-#### Owner did not call for a conference.
210.12(C)(3)-All 120 volt receptacle outlets located in bath area shall be on a dedicated 20 amp circuit and shall have no other outlets.
240.3(C)- 20 amp circuits shall be completed with 12 ga. wiring.
300.4- NM cable shall be secured at least 1 1/4" from framing surface.
314.16- Box fill shall not exceed rating on box.
BCC- Roof shall have moisture barrier installed. NM cable not rated for exposure to weather.
BCC- Make up shall be completed and boxes shall be installed at all light locations.
ELE15-01922 Final7/6/20157/7/20157/7/2015 9:45:11 AMAPASS
Bob Thomas Phone #: ###-#### Inspection requested via web by Kerri Hamilton Final ok
ELE15-01641 Final7/6/20157/7/20157/7/2015 9:20:07 AMACANC
Phone #: ###-#### Inspection requested via web by Greg Traudt Needed temp service inspection
ELE15-01641 Temporary Service7/7/20157/7/20157/7/2015 9:19:54 AMPPASS
Phone #: ###-#### Inspection requested via web by Greg Traudt t/s u/g n ok