ELE12-01442
| ELE-Aging Inspection | 7/8/2014 | 7/8/2014 | 7/8/2014 2:23:47 PM | | DONE |
|
|
Called and left message
|
ELE12-01429
| ELE-Aging Inspection | 7/8/2014 | 7/8/2014 | 7/8/2014 2:23:13 PM | | DONE |
|
|
Called contractor, he will check on job and schedule final
|
ELE12-02459
| ELE-Aging Inspection | 7/8/2014 | 7/8/2014 | 7/8/2014 2:22:23 PM | | DONE |
|
|
Still under construction
|
ELE14-00775
| Electrical Rough-In | 7/7/2014 | 7/8/2014 | 7/8/2014 2:21:24 PM | P | PASS |
|
|
Ceiling Cover. Toby is the onsite contact Phone #: ###-#### >> Inspection requested via web by Buster Bowen Infant recussitation and OR hard lid rough in ok cover
|
ELE14-01825
| Electrical Rough-In | 7/7/2014 | 7/8/2014 | 7/8/2014 1:23:05 PM | P | PASS |
|
|
Contact: Jeremy Thornock. ufer-ground inspection please Phone #: ###-#### >> Inspection requested via web by Deb Gooden Concrete encased electrode rough in ok cover
|
ELE14-01832
| Final | 7/7/2014 | 7/8/2014 | 7/8/2014 12:42:41 PM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Jonathan Poot Final ok
|
ELE14-01832
| Permanent Service | 7/8/2014 | 7/8/2014 | 7/8/2014 12:24:27 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Jonathan Poot p/s o/h rec ok
|
ELE14-01844
| Permanent Service | 7/8/2014 | 7/8/2014 | 7/8/2014 11:46:54 AM | P | PASS |
|
|
Call jimmy @ ###-#### for questions. Phone #: ###-#### >> Inspection requested via web by John Edwards Spoke with contractor about lowering mast for safe reconnect. p/s o/h rec ok
|
ELE14-01844
| Final | 7/8/2014 | 7/8/2014 | 7/8/2014 11:46:13 AM | P | PASS |
|
|
Call jimmy @ ###-#### for questions. Phone #: ###-#### >> Inspection requested via web by John Edwards Final ok
|
GCE14-00105
| GCE-Rough-In Permanent Service | 7/7/2014 | 7/8/2014 | 7/8/2014 11:03:44 AM | A | FAIL |
|
|
###-#### 300.4- NM cable shall be secured 1 1/4" from framing surface where possible or held off stud to reduce risk of damage. Bored holes less than 1 1/4" shall have nail plates. 314.29- Junction box by water heater shall be accessible. Poor access. 314.17- KO seal, unused opening in main disconnect shall be closed. 334.30- NM cale shall be secured with in 12" above panel. 362.30- ENT conduit shall be secured with in 3' of panel. 550.15(H)- NM cable under trailer not rated for damp locations. 408.38- Service dead front shall be installed to protect from accidental contact. 250.53- Where rod is used as grounding electrode it shall supplemented by additional rod.
|
ELE12-01972
| Final | 7/7/2014 | 7/8/2014 | 7/8/2014 10:02:14 AM | A | PASS |
|
|
Classy Casuals sign Phone #: ###-#### >> Inspection requested via web by Christen Carlson UL listing confirmed. Final ok
|
ELE14-01834
| Electrical Rough-In | 7/7/2014 | 7/8/2014 | 7/8/2014 9:53:05 AM | A | PASS |
|
|
Job is complete Phone #: ###-#### >> Inspection requested via web by Stuart Welton Rough in ok
|
ELE14-01834
| Final | 7/8/2014 | 7/8/2014 | 7/8/2014 9:52:35 AM | P | PASS |
|
|
Job is complete Phone #: ###-#### >> Inspection requested via web by Stuart Welton Final ok
|
ELE14-01745
| Temporary Service | 7/8/2014 | 7/8/2014 | 7/8/2014 9:35:44 AM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Alan Lusk t/s u/g n ok
|
ELE14-01029
| Electrical Rough-In | 7/7/2014 | 7/8/2014 | 7/8/2014 9:16:57 AM | A | FAIL |
|
|
floor heat // Jay Phone #: ###-#### 110.3 Floor heat system shall be installed to manufacturers instructions. Cold lead splice, end termination, and sensor tip shall be recessed in floor to avoid damage.
|
ELE14-01837
| Temporary Service | 7/8/2014 | 7/8/2014 | 7/8/2014 8:44:39 AM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by daniel bibikov t/s u/g n ok
|
ELE14-01836
| Temporary Service | 7/8/2014 | 7/8/2014 | 7/8/2014 8:44:03 AM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by daniel bibikov t/s u/g n ok
|
ELE14-01835
| Temporary Service | 7/8/2014 | 7/8/2014 | 7/8/2014 8:43:34 AM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by daniel bibikov t/s u/g n ok
|
ELE14-01414
| Final | 7/7/2014 | 7/8/2014 | 7/7/2014 2:00:29 PM | P | CANC |
|
|
Phone #: 6299948 >> Inspection requested via mobile web by David McClellan Inspection cancelled via mobile web on Monday, July 07, 2014.
|