MEC14-02327
| Rough-in | 7/7/2014 | 7/8/2014 | 7/8/2014 4:40:14 PM | P | PASS |
|
|
HVAC Installation Phone #: ###-#### >> Inspection requested via web by Randy Hart
|
MEC14-02641
| Rough-in | 7/7/2014 | 7/8/2014 | 7/8/2014 4:27:10 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Dan Otero
|
MEC14-02757
| Final | 7/7/2014 | 7/8/2014 | 7/8/2014 3:57:41 PM | P | FAIL |
|
|
Between 1 & 3 please. Call Maureen, ###-#### Phone #: ###-#### >> Inspection requested via web by April Thomas..prv must be turned down..add 2--90's and put a small hole in one of the horizontal sections
|
GCM14-00159
| GCM-Final | 7/8/2014 | 7/8/2014 | 7/8/2014 3:20:45 PM | P | FAIL |
|
|
Mary at Right Now ###-####..condensate not draining outside
|
GCM14-00094
| GCM-Final | 7/8/2014 | 7/8/2014 | 7/8/2014 3:19:53 PM | P | PASS |
|
|
oleg ###-####
|
GCM14-00128
| GCM-Rough-in | 7/8/2014 | 7/8/2014 | 7/8/2014 3:19:22 PM | P | PART |
|
|
Calvin ###-#### cover inspection in corridors 3&4....this should have been a conference..met with calvin and troy to discuss damper locations and concerns
|
GCM14-00167
| GCM-Final | 7/7/2014 | 7/8/2014 | 7/8/2014 3:15:47 PM | P | NH |
|
|
John ###-#### or owner Paul ###-####..left a note on the door
|
GCM14-00158
| GCM-Final | 7/7/2014 | 7/8/2014 | 7/8/2014 3:01:50 PM | P | PASS |
|
|
April ###-####
|
MEC14-02725
| Rough-in | 7/8/2014 | 7/8/2014 | 7/8/2014 12:15:45 PM | P | CANC |
|
|
HVAC INstallation Phone #: ###-#### >> Inspection requested via web by Randy Hart....r/i ok...NEED TO CHECK FOR DUCT BLAST STICKER AT FINAL
|
MEC14-02725
| Pressure Test | 7/8/2014 | 7/8/2014 | 7/8/2014 12:14:08 PM | P | FAIL |
|
|
HVAC INstallation Phone #: ###-#### >> Inspection requested via web by Randy Hart..need a new guage..it's all smashed in on the plate.. replace and re-test
|
MEC14-02056
| Final | 7/7/2014 | 7/8/2014 | 7/8/2014 11:51:35 AM | A | PASS |
|
|
Ready anytime tomorrow in am Phone #: ###-#### >> Inspection requested via web by Russ Curtis
|
MEC14-02501
| Pressure Test | 7/7/2014 | 7/8/2014 | 7/8/2014 11:23:06 AM | A | PASS |
|
|
Robert Phone #: ###-####..20lb gas ok
|
GCM14-00128
| GCM-Rough-in | 7/7/2014 | 7/8/2014 | 7/8/2014 11:22:20 AM | A | FAIL |
|
|
THIS IS FOR A COURTESY INSPECTION PER DIXIE, Calvin ###-####..need to extend platforms on all attic furnaces to access opening
|
MEC14-02327
| Pressure Test | 7/7/2014 | 7/8/2014 | 7/7/2014 2:04:33 PM | P | CANC |
|
|
HVAC Installation Phone #: ###-#### >> Inspection requested via web by Randy Hart Inspection cancelled from web by: Randy Hart
|
MEC14-02535
| Final | 7/2/2014 | 7/8/2014 | 7/2/2014 3:20:33 PM | P | CANC |
|
|
INSTALLER JAROD ###-#### Phone #: ###-#### >> Inspection requested via web by Dustin Rich Inspection cancelled from web by: Dustin Rich
|
MEC14-02535
| Pressure Test | 7/2/2014 | 7/8/2014 | 7/2/2014 3:20:31 PM | A | CANC |
|
|
INSTALLER JAROD ###-#### Phone #: ###-#### >> Inspection requested via web by Dustin Rich Inspection cancelled from web by: Dustin Rich
|