Inspections for the day of: Friday, July 8, 2016.
Number of inspections: 29
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJim Little
TitlePLM-INSPECTOR
Phone #869-5166
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM16-01144 Water Heater Final7/8/20167/8/20167/8/2016 4:15:55 PMPPASS
>correction made
PLM16-02443 DOC - Permit Finaled7/8/20167/8/20167/8/2016 4:06:16 PMPPASS
PLM16-02443 Water and/or Sewer7/7/20167/8/20167/8/2016 4:06:08 PMPPASS
Phone #: ###-#### Inspection requested via web by Darren Wood
MIS16-00192 DOC - Permit Finaled7/8/20167/8/20167/8/2016 3:39:32 PMPPASS
work has been permitted under appropiate trade permits
PLM16-02451 Final7/8/20167/8/20167/8/2016 3:37:52 PMPFAIL
Phone #: ###-#### Inspection requested via web by Todd Walter
>install unions at at boiler rp's.
PLM16-02452 DOC - Permit Finaled7/8/20167/8/20167/8/2016 3:06:32 PMPPASS
PLM16-02452 Water and/or Sewer7/8/20167/8/20167/8/2016 3:06:17 PMPCANC
PLUMBER ON SITE JOE ###-#### Phone #: ###-#### Inspection requested via web by Chris Field
>ws ok
PLM16-02427 Water and/or Sewer7/7/20167/8/20167/8/2016 2:30:01 PMPCANC
Inspection requested via web by Michael McDonald
PLM16-02427 Sprinkler (Final)7/8/20167/8/20167/8/2016 2:29:51 PMPPASS
Inspection requested via web by Michael McDonald
PLM16-02390 Sprinkler (Final)7/7/20167/8/20167/8/2016 2:16:17 PMPFAIL
Lincoln Phone #: ###-####
>leak
>must be 160 psi pipe up to DCVA
>ok to backfill to pipe
>recertify DCVA after new pipe is installed
PLM16-02436 Final7/7/20167/8/20167/8/2016 2:09:17 PMAPASS
MEL IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER
>all corrections made
PLM16-02436 Plumbing Rough-in7/7/20167/8/20167/8/2016 2:07:30 PMACANC
MEL IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER
PLM16-02436 Plumbing Rough-in7/8/20167/8/20167/8/2016 2:03:51 PMAFAIL
*Starbucks inside Fred Meyer*
This inspection was done on 6/28/16 under permit plm16-02080 before this new permit was pulled.
>support vertical copper drops every 10' and provide a mid story guide for pvc drop per table 3-2
>add hanger on 3" pvc horizontal vent before drop.
>add hanger on 3/4" copper water lines at tie in point so its supported every 6' per table 3-2
>run condensate drain from condenser seperate from ice bin drain to avoid contaminating the ice.
>need airgap on r/o drain and softener drain.
>need to verify airgap on ice maker and missing coffee equipment.
PLM16-02425 Plumbing Rough-in7/8/20167/8/20167/8/2016 1:56:32 PMPPASS
Phone #: ###-#### Inspection requested via web by Brian Johansen
PLM16-02450 DOC - Permit Finaled7/8/20167/8/20167/8/2016 1:42:11 PMPPASS
PLM16-02450 Water and/or Sewer7/8/20167/8/20167/8/2016 1:42:02 PMPPASS
Water main replacement hole in front yand water is on crawl access in back yard
Phone #: ###-#### Inspection requested via web by Mark Kelso
>new water service ok
PLM16-02447 Final7/8/20167/8/20167/8/2016 1:29:52 PMPPASS
Please call Jim 45 mins-1 hr prior to arrival ###-#### Phone #: ###-#### Inspection requested via web by Kassy Goodwin
>extended w/s ok
PLM16-02429 DOC - Permit Finaled7/8/20167/8/20167/8/2016 11:21:55 AMPPASS
PLM16-02429 Water and/or Sewer7/7/20167/8/20167/8/2016 11:21:12 AMAPASS
Doug Phone #: ###-####
PLM16-02433 Final7/7/20167/8/20167/8/2016 11:00:25 AMANH
PREFER 8AM / tech- Codie will need harness and safety equipment to pump up system for the MEC16-03043 portion of this inspection. Phone #: ###-#### Inspection requested via web by Kassy Goodwin
>not home
PLM15-03012 Final7/6/20167/8/20167/8/2016 10:47:08 AMAFAIL
door by the garage will be open. let me know when your headed that way, please. I''ll meet you there. Phone #: ###-#### Inspection requested via web by john richmond
>trim is not done, portion of work that was trimmed out was not done by this plumbing contractor.
PLM16-02409 Final7/6/20167/8/20167/8/2016 10:22:03 AMAFAIL
please call prior to arrival ###-#### or ###-#### Phone #: ###-#### Inspection requested via web by Kassy Goodwin
>need 1" airgap on softener drain
PLM16-02440 Final7/7/20167/8/20167/8/2016 9:58:30 AMAPASS
If questions please call Ryan @ ###-####. Phone #: ###-#### Inspection requested via web by Stacia Haumann
>capped and re-routed water lines ok
PLM16-02426 Other7/7/20167/8/20167/8/2016 9:09:27 AMAPASS
Please call Rudy to meet on site for a walk thru need to do a conference 9 am if at all possible Phone #: ###-#### Inspection requested via web by Kirk Johns
>conf on existing work, told Rudy it is ok to leave since it is not a safety or health issue.
PLM16-02432 Sprinkler (Final)7/7/20167/8/20167/8/2016 8:42:01 AMAPASS
Kevin Phone #: ###-####
PLM16-02280 Plumbing Rough-in7/7/20167/8/20167/8/2016 8:29:52 AMAPASS
BRAD IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER
PLM16-00279 PLM-Aging Inspection7/8/20167/8/20167/8/2016 8:03:08 AM PART
PLM15-01810 PLM-Aging Inspection7/8/20167/8/20167/8/2016 8:01:18 AM FAIL
no final insp on basement
PLM16-01144 Final7/5/20167/8/20167/5/2016 3:36:11 PMPCANC
not able to reach customer to schedule inspection multiple attempts ###-#### or ###-#### Phone #: ###-#### >> Inspection requested via web by Kassy Goodwin Inspection cancelled from web by: Kassy Goodwin