PLM04-01064
| PLM-Aging Inspection | 7/9/2004 | 7/9/2004 | 7/9/2004 12:00:00 AM | | PASS |
|
|
still under construction 7/9/2004 8:02:17 AM
|
PLM04-01879
| Plumbing Rough-in | 7/8/2004 | 7/9/2004 | 7/9/2004 12:00:00 AM | A | FAIL |
|
|
Roger; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes need to correct damaged pipe to washer box , vent down staires floor drain, need cleanouts at base of stack,s need to meet cross- sectional venting , support abs every 4 feet, support back hydrant, need to provide protection for piping through concrete wall test all DWV piping meet with plumber on job site contractor to recall when ready 7/9/2004 12:07:16 PM
|
PLM04-01885
| Plumbing Rough-in | 7/9/2004 | 7/9/2004 | 7/9/2004 12:00:00 AM | P | CANC |
|
|
kenny seepage bed; Phone #: ###-#### Internet Inspection Request from: Annette Moore need plubic work inspection for seepage bed 7/9/2004 1:12:19 PM
|
PLM04-01464
| Plumbing Rough-in | 7/9/2004 | 7/9/2004 | 7/9/2004 12:00:00 AM | P | FAIL |
|
|
Todd; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes test failed on DWV also need to move water lines to laves to front of 2x6 wall called Todd will recall when ready 7/9/2004 1:43:27 PM
|
PLM04-01469
| Final | 7/9/2004 | 7/9/2004 | 7/9/2004 12:00:00 AM | P | PASS |
|
|
John; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes
|
PLM04-01892
| Water and/or Sewer | 7/9/2004 | 7/9/2004 | 7/9/2004 12:00:00 AM | P | PASS |
|
|
###-#### - shawn
|
PLM04-01894
| Sprinkler (Final) | 7/9/2004 | 7/9/2004 | 7/9/2004 12:00:00 AM | P | PASS |
|
|
###-#### ken
|
PLM04-01896
| Water and/or Sewer | 7/9/2004 | 7/9/2004 | 7/9/2004 12:00:00 AM | P | PART |
|
|
kirt ###-#### or ###-#### water line only test ok ok to cover 7/9/2004 12:15:13 PM
|