Inspections for the day of: Wednesday, July 9, 2014.
Number of inspections: 28
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMike Jordan
TitleBLD-COM/RES INSPECTOR
Phone #794-9473
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD14-01480 BLD-Footing7/9/20147/9/20147/9/2014 4:43:28 PMPNR
Phone #: ###-#### Inspection requested via web by James Larkin
BLD14-01481 BLD-Footing7/9/20147/9/20147/9/2014 4:43:17 PMPNR
Phone #: ###-#### Inspection requested via web by James Larkin
BLD14-00207 BLD-Footing7/9/20147/9/20147/9/2014 4:15:01 PMPPASS
Dane-late pm please Phone #: ###-####
ESC14-00065 Site Preparation7/9/20147/9/20147/9/2014 4:14:39 PMPPASS
BLD14-01809 BLD-Final7/8/20147/9/20147/9/2014 4:00:22 PMPPART
Herb Phone #: ###-####. ok for temp occ. Needs to provide ADA compliant sales and service couter or provide letter to building official approving an alternate method of a seperate sales and service counter nearby.
BLD14-01482 BLD-Footing7/9/20147/9/20147/9/2014 3:15:07 PMPPASS
Phone #: ###-#### Inspection requested via web by James Larkin
BLD14-01483 BLD-Footing7/9/20147/9/20147/9/2014 3:14:28 PMPPASS
Phone #: ###-#### Inspection requested via web by James Larkin
BLD14-01479 BLD-Footing7/9/20147/9/20147/9/2014 3:14:03 PMPPASS
Phone #: ###-#### Inspection requested via web by James Larkin
BLD13-03532 BLD-Framing/Rough-in7/8/20147/9/20147/9/2014 2:58:15 PMPFAIL
Phone #: ###-#### Inspection requested via web by Brian Stark. Provide additional studs on either side of 2plyin garage to providebearing at end of wall, Also repair bottom plate at this location. Complete all fireblocking Provide 2 layers of 5/8 type x rock at soffits. Install baffels and rulers in attic. Steps in garge are non code compliant.
BLD13-03533 BLD-Framing/Rough-in7/8/20147/9/20147/9/2014 2:57:36 PMPFAIL
Phone #: ###-#### Inspection requested via web by Brian Stark. Provide additional studs on either side of 2plyin garage to providebearing at end of wall, Also repair bottom plate at this location. Complete all fireblocking Provide 2 layers of 5/8 type x rock at soffits. Install baffels and rulers in attic. Steps in garge are non code compliant.
BLD13-03534 BLD-Framing/Rough-in7/8/20147/9/20147/9/2014 2:56:56 PMPFAIL
Phone #: ###-#### Inspection requested via web by Brian Stark. Provide additional studs on either side of 2plyin garage to providebearing at end of wall, Also repair bottom plate at this location. Complete all fireblocking Provide 2 layers of 5/8 type x rock at soffits. Install baffels and rulers in attic. Steps in garge are non code compliant.
ESC13-01316 General Inspection7/9/20147/9/20147/9/2014 2:53:20 PMPPART
Needs to sweep all hard surfaces of silts and service BMP's. Correction notice posted.
ESC13-01317 General Inspection7/9/20147/9/20147/9/2014 2:52:58 PMPPART
Needs to sweep all hard surfaces of silts and service BMP's. Correction notice posted.
ESC13-01318 General Inspection7/9/20147/9/20147/9/2014 2:52:37 PMPPART
Needs to sweep all hard surfaces of silts and service BMP's. Correction notice posted.
BLD13-03532 BLD-Wall Bracing7/9/20147/9/20147/9/2014 2:49:14 PMPFAIL
Phone #: ###-#### Inspection requested via web by Brian Stark. Several areas were sheating is not attached. Correction notice posted.
BLD13-03533 BLD-Wall Bracing7/9/20147/9/20147/9/2014 2:48:34 PMPFAIL
Phone #: ###-#### Inspection requested via web by Brian Stark. Several areas were sheating is not attached. Correction notice posted.
BLD13-03534 BLD-Wall Bracing7/9/20147/9/20147/9/2014 2:48:08 PMPFAIL
Phone #: ###-#### Inspection requested via web by Brian Stark. Several areas were sheating is not attached. Correction notice posted.
BLD13-03538 BLD-Wall cover7/9/20147/9/20147/9/2014 2:46:49 PMPPASS
firewall construction Phone #: ###-#### Inspection requested via web by James Larkin. 3rd floor firewall ok.
BLD13-03539 BLD-Wall cover7/9/20147/9/20147/9/2014 2:46:20 PMPPASS
firewall construction Phone #: ###-#### Inspection requested via web by James Larkin. 3rd floor firewall ok.
BLD13-03536 BLD-Wall cover7/9/20147/9/20147/9/2014 11:42:47 AMAPASS
firewall construction Phone #: ###-#### Inspection requested via web by James Larkin3rd floor ok.
BLD13-03537 BLD-Wall cover7/9/20147/9/20147/9/2014 11:42:24 AMAPASS
firewall construction Phone #: ###-#### Inspection requested via web by James Larkin. #rd floor ok.
BLD14-01418 BLD-Final7/8/20147/9/20147/9/2014 10:00:25 AMADONE
Phone #: ###-#### Inspection requested via web by Laurie Hoelscher
BLD14-01418 DOC - Permit Finaled7/9/20147/9/20147/9/2014 10:00:14 AMPPASS
BLD14-00322 BLD-Wall cover7/9/20147/9/20147/9/2014 9:51:03 AMAPASS
First layer of drywall for fire rated ceiling for nailing. Mike can you make it later in the morning inspection like between 11 and 12....that would be great. Phone #: ###-#### Inspection requested via web by robert campbell
BLD14-00205 BLD-Energy code compliance7/8/20147/9/20147/9/2014 9:22:22 AMAPASS
Ashley-foundation energy Phone #: ###-####. rigid insulation on stemwall under slab on grade.
BLD14-00206 BLD-Footing7/9/20147/9/20147/9/2014 9:17:56 AMPCANC
late afternoon - Dane Phone #: ###-#### Inspection cancelled from web by: Barbara Stitt
BLD13-01075 BLD-Final7/8/20147/9/20147/9/2014 9:08:42 AMAPASS
Joe Phone #: ###-####. ok for perm occ.
GCB14-00075 GCB-Fndatn/slab ins/fld vent7/8/20147/9/20147/9/2014 8:45:12 AMAPASS