Inspections for the day of: Monday, July 9, 2018.
Number of inspections: 18
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Reynolds
TitleMEC INSPECTOR
Phone #208-803-2395
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC18-02618 Rough-in7/9/20187/9/20187/9/2018 4:34:35 PMPFAIL
Please call on way: Darrius ###-#### Phone #: ###-#### Inspection requested via web by Krista Boss- flex ducting is being smash by floor joistes- need to have an approved Man J.
MEC18-03242 Final7/9/20187/9/20187/9/2018 4:18:44 PMPNH
PLEASE CALL ON WAY: jOSH ###-#### Phone #: ###-#### Inspection requested via web by Krista Boss- homeowner didnt want to let me in
MEC18-03106 Rough-in7/9/20187/9/20187/9/2018 3:15:18 PMPPASS
Phone #: ###-#### Inspection requested via web by Gary Reeves- R/I ok
MEC18-03106 Pressure Test7/9/20187/9/20187/9/2018 3:15:04 PMPPASS
Phone #: ###-#### Inspection requested via web by Gary Reeves- 5lb flue ok- 20 lb gas ok
MEC18-03217 Final7/9/20187/9/20187/9/2018 3:04:14 PMPFAIL
Please call Maddie Phone #: ###-#### Inspection requested via web by Krista Boss
- need electrical permit pulled before final -furnace ac coil co ok-
MEC18-03217 Pressure Test7/9/20187/9/20187/9/2018 2:59:46 PMPPASS
Please call Maddie Phone #: ###-#### Inspection requested via web by Krista Boss
- 20lb gas pressure test ok
MEC18-03204 Final7/6/20187/9/20187/9/2018 2:39:50 PMPNR
INSTALLER BRANDAN ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- not ready
MEC18-03204 Pressure Test7/9/20187/9/20187/9/2018 2:39:27 PMPPASS
INSTALLER BRANDAN ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- 5lb flue pressure test ok
MEC18-03223 Rough-in7/6/20187/9/20187/9/2018 2:04:14 PMAPASS
Zachary or the GC ###-#### Todd Phone #: ###-####- R/I ok need to transfer air or ducted return into new room at final
MEC18-02873 Final7/6/20187/9/20187/9/2018 1:26:32 PMPPASS
please call Jamie in route ###-#### Phone #: ###-#### Inspection requested via web by Justin Osterhout- furnace ac coil co ok
MEC18-02857 Final7/9/20187/9/20187/9/2018 1:03:21 PMPPASS
Manufactured home Phone #: ###-#### Inspection requested via web by jamie berg- A/C coil co ok
MEC18-03083 Final7/3/20187/9/20187/9/2018 11:12:41 AMAFAIL
can you please call when you are on the way. Customers name is Gordon Reed and his number is ###-####. Thanks!! Phone #: ###-#### Inspection requested via web by Marisa Hone- lineset at outdoor unit needs to be supported and 3.5" off the ground- need to pull a plumbing permit for the water heater
MEC18-03106 Rough-in7/6/20187/9/20187/9/2018 10:09:09 AMAFAIL
Phone #: ###-#### Inspection requested via web by Gary Reeves
-water heater flue in attic needs 1" clearances(flex duct is touching flue)- supply runs into master room, master bath, and bedroom 3 are being pinched by supports. need to adjust flex for a free flowing run to boots- supply trunk in attic needs duct seal at Y - 5lb flue pressure test fail gauge wont zero
MEC18-03106 Pressure Test7/6/20187/9/20187/9/2018 10:05:57 AMAFAIL
Phone #: ###-#### Inspection requested via web by Gary Reeves- 5lb flue pressure test fail need to see gauge zero( replace gauage )
20lb gas pressure ok
MEC18-02838 Final7/3/20187/9/20187/9/2018 9:30:57 AMAFAIL
Phone #: ###-#### Inspection requested via web by Mary LaFayette-lineset penetration needs sealed at outdoor unit
MEC18-03099 Final7/3/20187/9/20187/9/2018 9:09:48 AMAFAIL
This is an empty home - the gate code is 2663 - must enter the gate on the orchard side. Phone #: ###-#### Inspection requested via web by Sabrina DeHority- new lineset penetration at indoor unit needs sealed and the old penetration at the indoor unit needs sealed- want to see co detectors installed through out house- lineset penetration at outdoor unit needs sealed- need UV protection on lineset- want to see electrical permit pulled for new location of power for A/C- There is also a remodel being done on the west side where new duct work is being installed need to see your permit show OTHER and fees paid- call in next time for rough- in of duct work
-Homeowners still live in house
MEC17-04659 Mec-Aging Inspection7/9/20187/9/20187/9/2018 9:06:21 AM DONE
house is still in rough- in phase- fireplace installer needs to call for final when the building process is complete
MEC18-03099 Pressure Test7/3/20187/9/20187/9/2018 8:57:31 AMAFAIL
This is an empty home - the gate code is 2663 - must enter the gate on the orchard side. Phone #: ###-#### Inspection requested via web by Sabrina DeHority- 5lb flue pressure test failed because gauge was at zero- also want to see the flue piping ran all the way to the furnace, looks like a few more fittings will be installed to make it to the furnace