Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE19-02500 Rough-In Permanent Service7/9/20197/9/20197/9/2019 2:00:05 PMPNR
Phone #: ###-#### Inspection requested via web by Alan Lusk
ELE19-01424 Electrical Rough-In7/9/20197/9/20197/9/2019 1:21:19 PMPPASS
Underground raceways rough in. Early p.m. inspection if possible.
Thanks Phone #: ###-#### Inspection requested via web by Tom Betty 6 spot lights around donor plaque area ok to cover
ELE19-01130 Final7/8/20197/9/20197/9/2019 10:57:59 AMAPASS
garage code 5339 Phone #: ###-#### Inspection requested via web by Ryan Wake Corrections made final ok
ELE19-02504 Electrical Rough-In7/8/20197/9/20197/9/2019 9:31:20 AMAFAIL
Please call Juan with any questions Phone #: ###-#### Inspection requested via web by William Salts No answer amilbox not set up. 110.3B Listed equipment shall be installed as per manufacturer instructions. (2 gang nail on in kitchen. Use a listed screw on box) 300.4A1. Cables through bored holes less than 1 1/4in from face of stud shall be protected. BCC Section 9-05-32 Violations shall not be retained>
ELE19-01516 Final7/8/20197/9/20197/9/2019 9:09:59 AMAPASS
call for code Phone #: ###-#### Inspection requested via web by Robert Murray corrections made final ok
ELE19-01100 Final7/9/20197/9/20197/9/2019 9:08:17 AMPPASS
garage code 2018 or 2019 Phone #: ###-#### Inspection requested via web by Darryn Coburn Corrections made final ok
ELE19-02317 Final7/8/20197/9/20197/9/2019 8:18:51 AMANR
garage code 2018 or 2019 Phone #: ###-#### Inspection requested via web by Darryn Coburn Wrong address called in