Inspections for the day of: Thursday, July 9, 2020.
Number of inspections: 6
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE20-02323 Electrical Rough-In7/9/20207/9/20207/9/2020 2:44:26 PMPPASS
I will take a video and send it to you Phone #: ###-#### Inspection requested via web by Shaun Kirkman Verified thru contractor video Kitchen remodel rough in ok cover.
ELE20-02341 Electrical Rough-In7/8/20207/9/20207/9/2020 2:22:01 PMAPASS
Dan ###-#### Phone #: ###-#### Inspection requested via web by Dan Hobdey Verifyed thru photos. Up bathroom rough in ok cover.
ELE20-02312 Rough-In Permanent Service7/8/20207/9/20207/9/2020 2:06:23 PMPFAIL
Please call me before you head down, have a great day. Can be a.m. if necessary. Phone #: ###-#### Inspection requested via web by TRENT Swaim City approved set of prints on site confirmed. Basement to remain unfinished. Daylite responsive control noted on print. 110.12(B)- Existing electrical boxes in basement shall not be damaged. Bent, loose, not secured. 110.24- Available fault current shall be posted prior to approving permanent service. 210.62- Show window receptacles shall be installed for all major fraction of 12' of show window space. 6' of window and area above front door. 220.14(G)- Branch circuit calculation for show window lengths of 22', 24, and 6'= 10.4 kw. A minimum of 5 20 amp 120 volt circuit for show window receptacles. 250.24(A)(1)- Grounding electrode conductor shall terminate and same bus or terminal as grounded conductor in right panel. 300.4- MC cable shall be protected form damage where run thru notched wood by nail plates. Basement beans and upstairs above door. 314.23- Boxes shall be securely mounted in place. Up west wall and basement existing boxes 330.30- MC shall be secured with in 12" of a box. Level 1 east wall and few lights. 408.7- Unused breaker space shall be closed by approved means.
ELE20-00912 Electrical Rough-In7/8/20207/9/20207/9/2020 10:46:13 AMAFAIL
Master bathroom floor heat. Phone #: ###-#### Inspection requested via web by Barbara Szurgot 110.3- All floor heat components shall be installed as per instructions. Instructions not on site. temp sensor not installed. 314.17- Cables entering non-metllic boxes shall be secured to box. Install cable connectors where cables enter thermostat box.
ELE20-02156 Rough-In Permanent Service7/8/20207/9/20207/9/2020 9:39:45 AMAPASS
Phone #: ###-#### Inspection requested via web by Rodney Monroe Rough in ok cover p/s u/g n ok
ELE20-02155 Rough-In Permanent Service7/8/20207/9/20207/9/2020 9:00:57 AMAPASS
Phone #: ###-#### Inspection requested via web by Rodney Monroe Rough in ok cover p/s u/g n ok