Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD12-00168 BLD-Final7/31/20128/1/20128/1/2012 4:09:25 PMPNR
Please contact Chris Palmer @ ###-#### to set up a meeting time for the inspection. Phone #: ###-#### >> Inspection requested via web by Brandon McCurdy. Fire/life/safety failed. Will recall for the pm tomorrow.
ESC12-00696 Site Preparation8/1/20128/1/20128/1/2012 2:39:12 PMPPASS
BLD12-01765 BLD-Footing8/1/20128/1/20128/1/2012 2:38:57 PMPPASS
Phone #: 2089410987 >> Inspection requested via mobile web by Bill
BLD12-01764 BLD-Footing8/1/20128/1/20128/1/2012 2:38:22 PMPPASS
Phone #: 2089410987 >> Inspection requested via mobile web by Bill
ESC12-00692 Site Preparation8/1/20128/1/20128/1/2012 2:38:04 PMPPASS
BLD12-01767 BLD-Footing8/1/20128/1/20128/1/2012 2:37:44 PMPPASS
Phone #: 2089410987 >> Inspection requested via mobile web by Bill
ESC12-00695 Site Preparation8/1/20128/1/20128/1/2012 2:37:31 PMPPASS
ESC12-00694 Site Preparation8/1/20128/1/20128/1/2012 2:37:17 PMPPASS
BLD12-01763 BLD-Footing8/1/20128/1/20128/1/2012 2:37:05 PMPPASS
Phone #: 2089410987 >> Inspection requested via mobile web by Bill
ESC12-00691 Site Preparation8/1/20128/1/20128/1/2012 2:36:48 PMPPASS
BLD12-01766 BLD-Footing8/1/20128/1/20128/1/2012 2:36:36 PMPPASS
Phone #: 2089410987 >> Inspection requested via mobile web by Bill
BLD12-01768 BLD-Footing8/1/20128/1/20128/1/2012 2:36:23 PMPPASS
Phone #: 2089410987 >> Inspection requested via mobile web by Bill
ESC12-00693 Site Preparation8/1/20128/1/20128/1/2012 2:36:10 PMPPASS
ESC12-00163 Site Preparation8/1/20128/1/20128/1/2012 2:22:04 PMPPART
ESC permit sign and SWPPP is posted. Needs to provide concrete washout, provide BMP around excavated materials on asphalt and provide containment for porta pots on hard surfaces.
BLD12-00382 BLD-Footing7/31/20128/1/20128/1/2012 2:20:13 PMPPART
kim Phone #: ###-####. Area1, column and pier pad footings on grids 14.2 and 16. Footings on grids 14.1, 14.2 and 15.5 and south footing for lounge. Steed super on vacation, contacted concrete sub (Kim) and noted to have sluff cleaned out prior to concrete placement. Verified that thier will be special inspection. Will have steed verify by contract that special inspector is working for owner or design pro when steed super is back.
GCB12-00003 GCB-Framing7/31/20128/1/20128/1/2012 9:54:00 AMAPASS
Dave @ ###-####
AM inspection requested
Framing in front. Remainder of over build north west corner of building ok.
BLD12-01705 BLD-Framing/Rough-in7/31/20128/1/20128/1/2012 9:24:46 AMAPART
Tom Phone #: ###-####. INterior steel stud framed walls only. Pending electrical rough in inspection.