Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC13-00641 Site Final8/1/20138/1/20138/9/2013 5:01:28 PMPFAIL
Cannot final until new permit is issued.
ESC13-00034 Aging Inspection8/1/20138/1/20138/6/2013 7:03:05 AM CANC
ESC13-00230 General Inspection8/1/20138/1/20138/2/2013 4:04:11 PM PART
Silt fence needs repaired. Entire site looks to be active. Dust under control despite traffic on disturbed area and earth work
ESC13-00013 BMP Violation7/31/20138/1/20138/1/2013 2:38:02 PMPFAIL
SWO issued: repair silt fence; sweep side walk and gutter. Chance of T-storms tonight
ESC13-00401 Random Inspection8/1/20138/1/20138/1/2013 1:33:24 PMPFAIL
Entire backyard/slope has been disturbed and is bare dirt for new landscaping. This was not approved in the waiver. Permit has been modified to reflect this additional disturbance and a modification fee of $78.75 is due. Landscapers expect sod to be installed in one week. Will re-inspect 8/9. Will issue SWO if fee and sod is not in by 8/9.
ESC13-00158 DOC - Permit Finaled8/1/20138/1/20138/1/2013 1:15:47 PMPPASS
see ESC13-00401 for vertical construction
ESC13-00339 General Inspection8/1/20138/1/20138/1/2013 11:23:32 AM FAIL
Written correction notice: 1. Install RECP jute matting per spec as discussed on 7/11. 2. Clean up concrete washout not contained in pit; schedule maintanance on pit as it is near full capacity. 3. Sweep gutter regularly as needed. Failure to address these by next inspection will result in a SWO.
ESC12-00634 DOC - Permit Finaled8/1/20138/1/20138/1/2013 10:58:35 AMPPASS
ESC12-00633 DOC - Permit Finaled8/1/20138/1/20138/1/2013 10:58:15 AMPPASS
ESC12-00632 DOC - Permit Finaled8/1/20138/1/20138/1/2013 10:57:55 AMPPASS
ESC12-00631 DOC - Permit Finaled8/1/20138/1/20138/1/2013 10:57:17 AMPPASS
ESC13-00288 General Inspection8/1/20138/1/20138/1/2013 10:53:58 AM FAIL
Written Correction Notice: to amend ECP project schedule. Not even close to final completion. Trash needs cleaned up; Needs dust control where pulling from stockpile. Maintain street sweeping as needed; improve construction exits as neccessary (50' min, clean 2' plus rock); Concrete washout needs improvement ; Evidence of runoff running toward street from pump truck on ground by existing washout location; Post ESC sign
ESC13-00250 General Inspection8/1/20138/1/20138/1/2013 9:46:36 AM PASS
Inlet protection still in good shape. building demo close to complete; still actively working disturbed areas.
ESC12-00681 General Inspection8/1/20138/1/20138/1/2013 9:36:45 AM PASS
Has not achieved any vegetation yet. Will need to continue maintaining temp stabilization until vegetation grows in. Note: site is contoured inward; little to no risk of runoff
ESC13-00213 General Inspection8/1/20138/1/20138/1/2013 9:20:29 AMPFAIL
Supplement to previous entry: must protect storm drains down gradient on Castello.
ESC11-00879 General Inspection8/1/20138/1/20138/1/2013 9:16:58 AM PASS
ESC13-00013 Stop Work Order8/1/20138/1/20138/1/2013 12:00:00 AMPDONE