ELE12-02777
| ELE-Aging Inspection | 8/1/2014 | 8/1/2014 | 8/6/2014 11:15:50 AM | | DONE |
|
|
too busy
|
ELE12-01617
| ELE-Aging Inspection | 8/1/2014 | 8/1/2014 | 8/4/2014 9:53:03 AM | | PASS |
|
|
final ok
|
ELE14-00250
| Final | 8/1/2014 | 8/1/2014 | 8/1/2014 1:59:45 PM | P | FAIL |
|
|
Josh is contact Phone #: ###-#### Inspection requested via web by Chris Chesnut 210.8 (A)(2) -garage outlets all need GFCI protection, 314.20-no more than 1/4" from finish surface to front edge of box(kitchen backsplash, 422.31- lockofss on cir. breakers for microwave and dbl. oven, loose kitchen counter recetacle, 2" strap on meter base conduit, dnst. laundry room has GFCI on GFCI from upst. bath
|
ELE14-01409
| Electrical Rough-In | 8/1/2014 | 8/1/2014 | 8/1/2014 1:00:20 PM | P | FAIL |
|
|
ceiling grid for access call 86992600 Phone #: ###-#### Inspection requested via web by Lars Johnson 330.30(B)-secure MC cable within 6" of box, recessed can lights need seismic wire with identification, close up junction boxes
|
ELE14-02099
| Temporary Service | 8/1/2014 | 8/1/2014 | 8/1/2014 12:38:16 PM | P | PASS |
|
|
Joe Phone #: ###-#### t/s o/h n ok
|
ELE14-02034
| Electrical Rough-In | 7/31/2014 | 8/1/2014 | 8/1/2014 11:53:09 AM | A | PART |
|
|
partial r/i // Keith Phone #: ###-#### partial r/i ok see A2.0 sheets
|
ELE14-00951
| Final | 8/1/2014 | 8/1/2014 | 8/1/2014 10:47:08 AM | P | FAIL |
|
|
Victoria Phone #: ###-#### all outside conv. outlets need GFCI protection
|
ELE14-01852
| Final | 8/1/2014 | 8/1/2014 | 8/1/2014 10:26:50 AM | P | PASS |
|
|
final inspection 7/3 Poplar Glen Phone #: ###-#### Inspection requested via web by Rowdy Monroe FINAL OK
|
ELE14-02097
| Temporary Service | 8/1/2014 | 8/1/2014 | 8/1/2014 9:45:04 AM | A | PASS |
|
|
temp power pole Phone #: ###-#### Inspection requested via web by Rowdy Monroe t/s u/g n ok A;READY ENERGIZED AND METER SET
|
ELE14-02096
| Temporary Service | 8/1/2014 | 8/1/2014 | 8/1/2014 9:36:23 AM | A | PASS |
|
|
temp power pole Phone #: ###-#### Inspection requested via web by Rowdy Monroe t/s u/g n ok ALREADY ENERGIZED AND METER SET
|
GCE13-00191
| GCE-Rough-In | 7/31/2014 | 8/1/2014 | 8/1/2014 9:27:23 AM | A | PASS |
|
|
Rough-In for Office r/i ok remainder of lobby walls and ceilings and offices and kitchen ceiling only
|