Inspections for the day of: Friday, August 10, 2007.
Number of inspections: 16
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJim Johnson
TitlePLM-INSPECTOR
Phone #794-9476
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM07-01151 Final8/10/20078/10/20078/10/2007 4:28:48 PMPNH
Per Kathryn..Please call Steve @ ###-#### with questions. Thanks! Phone #: ###-#### Internet Inspection Request from: Sonja Hankel no access
PLM07-01149 Final8/10/20078/10/20078/10/2007 4:28:08 PMPNH
Per Kathryn..Please call Steve @ ###-#### with questions. Thanks! Phone #: ###-#### Internet Inspection Request from: Sonja Hankel no access
PLM07-00200 Final8/10/20078/10/20078/10/2007 3:43:42 PMPFAIL
jason Phone #: ###-#### need to repipe trap arm for lav in powder room vent pipe opening shall not be below the weir of the trap upc 905.5 2003
PLM07-00201 Final8/10/20078/10/20078/10/2007 3:37:45 PMPPASS
jason Phone #: ###-####
PLM06-04035 Final8/10/20078/10/20078/10/2007 3:09:05 PMPPASS
jason Phone #: ###-####
PLM07-00847 Final8/10/20078/10/20078/10/2007 2:59:44 PMPPASS
todd Phone #: ###-####
PLM06-01733 Final8/10/20078/10/20078/10/2007 2:11:34 PMPPASS
bob Phone #: ###-####
PLM07-02714 Plumbing Rough-in8/10/20078/10/20078/10/2007 1:20:49 PMPPASS
Ken ###-####
PLM07-00921 PLM-Aging Inspection8/10/20078/10/20078/10/2007 11:24:52 AM PASS
no request for final
PLM07-00807 Final8/9/20078/10/20078/10/2007 11:23:13 AMAPASS
Re-inspection per inspector--double check valve inspection is done. Contact: Dan or Linda Phone #: ###-#### Internet Inspection Request from: Linda Peterson
PLM07-02703 Sprinkler (Final)8/9/20078/10/20078/10/2007 10:01:43 AMAFAIL
###-#### saul RP cannot be installed in vault needto be 12 inches above finished grade as per table 6-2 upc need to uncover tie-in to water line and all connections for inspection upc 103.5.1.4 need to have backflow device tested and certified by a certified tester left correction notice on site and called contractor
PLM07-02688 Sprinkler (Final)8/8/20078/10/20078/10/2007 9:02:30 AMAPASS
carol Phone #: ###-####
PLM07-00177 PLM-Aging Inspection8/10/20078/10/20078/10/2007 7:57:31 AM PASS
PLM07-00177 DOC - Permit Finaled8/10/20078/10/20078/10/2007 7:57:22 AMAPASS
PLM07-01074 PLM-Aging Inspection8/10/20078/10/20078/10/2007 7:56:21 AM PASS
PLM07-01074 DOC - Permit Finaled8/10/20078/10/20078/10/2007 7:56:07 AMAPASS