PLM07-01151
| Final | 8/10/2007 | 8/10/2007 | 8/10/2007 4:28:48 PM | P | NH |
|
|
Per Kathryn..Please call Steve @ ###-#### with questions. Thanks! Phone #: ###-#### Internet Inspection Request from: Sonja Hankel no access
|
PLM07-01149
| Final | 8/10/2007 | 8/10/2007 | 8/10/2007 4:28:08 PM | P | NH |
|
|
Per Kathryn..Please call Steve @ ###-#### with questions. Thanks! Phone #: ###-#### Internet Inspection Request from: Sonja Hankel no access
|
PLM07-00200
| Final | 8/10/2007 | 8/10/2007 | 8/10/2007 3:43:42 PM | P | FAIL |
|
|
jason Phone #: ###-#### need to repipe trap arm for lav in powder room vent pipe opening shall not be below the weir of the trap upc 905.5 2003
|
PLM07-00201
| Final | 8/10/2007 | 8/10/2007 | 8/10/2007 3:37:45 PM | P | PASS |
|
|
jason Phone #: ###-####
|
PLM06-04035
| Final | 8/10/2007 | 8/10/2007 | 8/10/2007 3:09:05 PM | P | PASS |
|
|
jason Phone #: ###-####
|
PLM07-00847
| Final | 8/10/2007 | 8/10/2007 | 8/10/2007 2:59:44 PM | P | PASS |
|
|
todd Phone #: ###-####
|
PLM06-01733
| Final | 8/10/2007 | 8/10/2007 | 8/10/2007 2:11:34 PM | P | PASS |
|
|
bob Phone #: ###-####
|
PLM07-02714
| Plumbing Rough-in | 8/10/2007 | 8/10/2007 | 8/10/2007 1:20:49 PM | P | PASS |
|
|
Ken ###-####
|
PLM07-00921
| PLM-Aging Inspection | 8/10/2007 | 8/10/2007 | 8/10/2007 11:24:52 AM | | PASS |
|
|
no request for final
|
PLM07-00807
| Final | 8/9/2007 | 8/10/2007 | 8/10/2007 11:23:13 AM | A | PASS |
|
|
Re-inspection per inspector--double check valve inspection is done. Contact: Dan or Linda Phone #: ###-#### Internet Inspection Request from: Linda Peterson
|
PLM07-02703
| Sprinkler (Final) | 8/9/2007 | 8/10/2007 | 8/10/2007 10:01:43 AM | A | FAIL |
|
|
###-#### saul RP cannot be installed in vault needto be 12 inches above finished grade as per table 6-2 upc need to uncover tie-in to water line and all connections for inspection upc 103.5.1.4 need to have backflow device tested and certified by a certified tester left correction notice on site and called contractor
|
PLM07-02688
| Sprinkler (Final) | 8/8/2007 | 8/10/2007 | 8/10/2007 9:02:30 AM | A | PASS |
|
|
carol Phone #: ###-####
|
PLM07-00177
| PLM-Aging Inspection | 8/10/2007 | 8/10/2007 | 8/10/2007 7:57:31 AM | | PASS |
|
|
|
PLM07-00177
| DOC - Permit Finaled | 8/10/2007 | 8/10/2007 | 8/10/2007 7:57:22 AM | A | PASS |
|
|
|
PLM07-01074
| PLM-Aging Inspection | 8/10/2007 | 8/10/2007 | 8/10/2007 7:56:21 AM | | PASS |
|
|
|
PLM07-01074
| DOC - Permit Finaled | 8/10/2007 | 8/10/2007 | 8/10/2007 7:56:07 AM | A | PASS |
|
|
|