Inspections for the day of: Wednesday, August 10, 2011.
Number of inspections: 16
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorDaryl DeGrange
TitleELE-INSPECTION SUPV
Phone #794-1379
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE09-00849 ELE-Aging Inspection8/10/20118/10/20118/11/2011 2:32:27 PM DONE
still under construction
ELE10-02860 Final8/10/20118/10/20118/10/2011 4:02:19 PMPPASS
job complete final ok
ELE10-02860 ELE-Aging Inspection8/10/20118/10/20118/10/2011 4:02:01 PM DONE
see final
ESC11-00199 Site Final8/10/20118/10/20118/10/2011 3:59:35 PMPPASS
site clean, landscaping all in. final ok
ESC11-00565 Site Final8/10/20118/10/20118/10/2011 3:53:35 PMPPASS
site clean, landscaping all in, final ok
ELE11-01829 Electrical Rough-In8/10/20118/10/20118/10/2011 2:42:52 PMPPASS
Phone #: ###-#### >> Inspection requested via web by daniel bibikov rough-in ok cover bedroom addition
ELE11-01377 Final8/9/20118/10/20118/10/2011 2:20:12 PMPPASS
Final inspection. Contact name is CJ. Thanks Phone #: ###-#### >> Inspection requested via web by Chris Chesnut final ok
ELE10-02134 Conference8/9/20118/10/20118/10/2011 1:39:24 PMADONE
Chris is the contact his cell no. is ###-####. Phone #: ###-#### >> Inspection requested via web by Shawna Gates contractor had questions on work desks found UL listing tags and generator cabnet door clearance-doors will open 90 degrees
ELE11-01828 Permanent Service8/10/20118/10/20118/10/2011 1:06:26 PMPPASS
inspection to have meter set Phone #: ###-#### >> Inspection requested via web by Brad Baker p/s u/g meter pac ok
ELE11-01748 Electrical Rough-In8/9/20118/10/20118/10/2011 12:49:56 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Clint Tate rough-in ok cover classroom # 200
ELE11-01765 Electrical Rough-In8/9/20118/10/20118/10/2011 12:29:59 PMAPASS
dave - garage only Phone #: ###-#### rough-in ok cover unattach garage
ELE10-02651 ELE-Aging Inspection8/10/20118/10/20118/10/2011 10:26:08 AM DONE
still under construction
ELE11-01791 Electrical Rough-In8/9/20118/10/20118/10/2011 10:19:52 AMAFAIL
tracy - please call 1/2 hr prior Phone #: ###-#### NEC 300.4 NM cable shall be 1 1/4 from edge of framing memeber. NEC 300.14 Shall provide 6" free conductor lenght at boxes
ELE11-01819 Electrical Rough-In8/9/20118/10/20118/10/2011 9:50:52 AMAFAIL
Phone #: ###-#### >> Inspection requested via web by Larry Richardson NEC210.11(C)(3) At least one 20 ampere branch circuit shall be provided to supply bathroom receptacle,such circuits shall have no other outlets
ELE11-01769 Conference8/9/20118/10/20118/10/2011 9:09:40 AMADONE
call when on way//Max Phone #: ###-#### Discuss with home owner service locations, stapling, 1 /14 from from edge of framing member, smoke detector locations
ELE11-01574 Final8/9/20118/10/20118/10/2011 8:44:32 AMAPASS
Final for this location please. Contact is Bob Callahan. Thank you and enjoy your day! Phone #: ###-#### >> Inspection requested via web by Laura Longshaw