ELE12-01740
| Final | 8/9/2012 | 8/10/2012 | 8/13/2012 9:53:56 AM | A | PASS |
|
|
Contact Craig Timmons before heading out so he can meet you there ###-####. Phone #: ###-#### >> Inspection requested via web by Tina Payne final ok
|
ELE12-01988
| Permanent Service | 8/8/2012 | 8/10/2012 | 8/10/2012 5:01:55 PM | P | PASS |
|
|
Gary Phone #: ###-#### p/s o/h rec ok
|
GCE12-00122
| GCE-Rough-In | 8/10/2012 | 8/10/2012 | 8/10/2012 4:43:06 PM | P | FAIL |
|
|
Matt @ ###-#### AFternoon inspection requested for today. Corrections still exsist UL's White book page 305 photovltaic modules and panels (UL mark)
|
ELE12-01997
| Final | 8/10/2012 | 8/10/2012 | 8/10/2012 4:01:21 PM | P | PASS |
|
|
final ok
|
ELE12-01997
| Electrical Rough-In | 8/9/2012 | 8/10/2012 | 8/10/2012 4:01:04 PM | P | PASS |
|
|
Mike Phone #: ###-#### lighting retro canopy LED lighting UL listed rough-in ok
|
ELE12-02005
| Electrical Rough-In | 8/9/2012 | 8/10/2012 | 8/10/2012 3:47:55 PM | P | PASS |
|
|
SITE IS ON FIRST FLOOR STE 160. cONTACT IS SID ###-#### Phone #: ###-#### >> Inspection requested via web by JENNY EMEL rough-in ok cover walls and pour concrete as per marked on plans and dated 8/10/12
|
ELE11-02692
| Electrical Rough-In | 8/10/2012 | 8/10/2012 | 8/10/2012 3:19:44 PM | P | PASS |
|
|
Contact: Tony Holt - underground inspection, late morning or early afternoon if possible please Phone #: ###-#### >> Inspection requested via web by Deb Gooden rough-in ok cover underground for lighting pole fixtures along Myrtle St
|
ELE12-02003
| Conference | 8/9/2012 | 8/10/2012 | 8/10/2012 2:49:04 PM | A | PASS |
|
|
call 1/2 before//darin Phone #: ###-#### Discuss with homeowner requirements for single family remodel complete with service upgrade
|
ELE12-01755
| Final | 8/9/2012 | 8/10/2012 | 8/10/2012 1:45:38 PM | A | PASS |
|
|
Patrick is contact. Thanks! Phone #: ###-#### >> Inspection requested via web by Chris Chesnut
|
ELE12-01322
| Final | 8/9/2012 | 8/10/2012 | 8/10/2012 1:44:10 PM | A | FAIL |
|
|
Patrick is contact. Thanks Phone #: ###-#### >> Inspection requested via web by Chris Chesnut NEC 410.16 (B) Walkin closet Incandescent luminaires with open or partially enclosed lamps shall not be permitted
|
ELE12-02004
| Electrical Rough-In | 8/9/2012 | 8/10/2012 | 8/10/2012 1:14:32 PM | A | PASS |
|
|
conduit and grounding Phone #: ###-#### >> Inspection requested via web by Mike Okamura rough-in ok cover underground
|
ELE12-01911
| Final | 8/10/2012 | 8/10/2012 | 8/10/2012 10:12:41 AM | P | PASS |
|
|
final ok
|
ELE12-01911
| Electrical Rough-In | 8/9/2012 | 8/10/2012 | 8/10/2012 10:11:49 AM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by PAT MILLER rough-in ok
|
ELE12-01983
| Final | 8/10/2012 | 8/10/2012 | 8/10/2012 10:03:33 AM | A | PASS |
|
|
final ok
|
ELE12-01983
| Permanent Service | 8/9/2012 | 8/10/2012 | 8/10/2012 10:02:40 AM | A | PASS |
|
|
Ready for inspection as we discussed yesterday. Thanks, Dan. Phone #: ###-#### >> Inspection requested via web by Dan Mitchell p/s o/h n ok
|
ELE11-01872
| Final | 8/9/2012 | 8/10/2012 | 8/10/2012 9:53:01 AM | A | PASS |
|
|
>> Inspection requested via web by Patrick Paz final ok
|
ELE12-01493
| Electrical Rough-In | 8/10/2012 | 8/10/2012 | 8/10/2012 9:42:28 AM | A | PASS |
|
|
garage is wired Phone #: ###-#### >> Inspection requested via web by Neal Rumsey rough-in ok cover detached garage
|
GCE12-00122
| GCE-Rough-In | 8/9/2012 | 8/10/2012 | 8/10/2012 9:24:20 AM | A | FAIL |
|
|
Matt @ ###-#### Call in advance Solar Photovoltaic system, NEC 110.3(B) Equipment not listed with nationally recongnized testing lab
|
GCE12-00060
| GCE-Final | 8/8/2012 | 8/10/2012 | 8/10/2012 8:49:27 AM | A | NR |
|
|
Chris @ ###-####
|
ELE12-00409
| Final | 8/9/2012 | 8/10/2012 | 8/10/2012 8:30:45 AM | A | PASS |
|
|
Hooked up the trailer to the new meter on the pole and capped off the old underground feed. Call Jimmy @ ###-#### for questions. Phone #: ###-#### >> Inspection requested via web by John Edwards final ok
|
ELE12-01995
| Electrical Rough-In | 8/9/2012 | 8/10/2012 | 8/9/2012 5:08:30 PM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by kevin blackmon rough-in ok cover
|