Inspections for the day of: Monday, August 10, 2015.
Number of inspections: 9
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorDaryl DeGrange
TitleELE-INSPECTION SUPV
Phone #794-1379
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE15-01873 Final8/10/20158/10/20158/10/2015 2:55:29 PMPPASS
Phone #: ###-#### Inspection requested via web by kendall bender correction done, final ok
ELE15-02474 Permanent Service8/10/20158/10/20158/10/2015 2:15:23 PMPFAIL
Phone #: ###-#### Inspection requested via web by Thomas Jenkins Temp. pole feeders NEC 300.(5) dept 24 in. for direct burial, 18 in. for PVC sleeve. Staple grounding electrode conductor.
ELE15-01912 Electrical Rough-In8/10/20158/10/20158/10/2015 1:41:46 PMPPASS
Earl Phone #: ###-#### Rough-in ok cover dinning room and garage walls
ELE15-02489 Electrical Rough-In8/10/20158/10/20158/10/2015 1:18:12 PMPFAIL
Cover inspection Phone #: ###-#### Inspection requested via web by Spencer McLean NEC 300.4 ENT installed for low voltage wiring shall be protected from phyical damage
ELE15-01291 Final8/10/20158/10/20158/10/2015 11:09:22 AMAPASS
add smoke detectors in duplex, job complete, final ok
ELE15-02467 Permanent Service8/7/20158/10/20158/10/2015 11:08:36 AMAPASS
relocation of service Phone #: ###-#### Inspection requested via web by Charles Davis duplex p/s u/g rec ok
ELE15-02159 Electrical Rough-In8/6/20158/10/20158/10/2015 10:14:18 AMAPASS
Potting, Bonding, and Underground conduits Inspection Phone #: ###-#### Inspection requested via web by Louis Keller Equipoyential bonding not completed at this time. Rough-in ok cover
ELE15-02458 Electrical Rough-In8/7/20158/10/20158/10/2015 9:49:39 AMAFAIL
Any questions please let me know, thx, TW. Phone #: ###-#### Inspection requested via web by Stephen Kren Not all insulation removed for inspection, (ceiling, foam seal back of service)
ELE15-02477 Final8/7/20158/10/20158/10/2015 9:26:47 AMAFAIL
I will have a technician there between 8:30-9:00, so he can check the service.
If you have any questions, please call the office. Thank You. Phone #: ###-#### Inspection requested via web by Clay Morgan NEC 230.6(5) Unfused service feeders shall not be routed through walls of a building.NEC 250.56 Two ground rods