ELE15-01873
| Final | 8/10/2015 | 8/10/2015 | 8/10/2015 2:55:29 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by kendall bender correction done, final ok
|
ELE15-02474
| Permanent Service | 8/10/2015 | 8/10/2015 | 8/10/2015 2:15:23 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Thomas Jenkins Temp. pole feeders NEC 300.(5) dept 24 in. for direct burial, 18 in. for PVC sleeve. Staple grounding electrode conductor.
|
ELE15-01912
| Electrical Rough-In | 8/10/2015 | 8/10/2015 | 8/10/2015 1:41:46 PM | P | PASS |
|
|
Earl Phone #: ###-#### Rough-in ok cover dinning room and garage walls
|
ELE15-02489
| Electrical Rough-In | 8/10/2015 | 8/10/2015 | 8/10/2015 1:18:12 PM | P | FAIL |
|
|
Cover inspection Phone #: ###-#### Inspection requested via web by Spencer McLean NEC 300.4 ENT installed for low voltage wiring shall be protected from phyical damage
|
ELE15-01291
| Final | 8/10/2015 | 8/10/2015 | 8/10/2015 11:09:22 AM | A | PASS |
|
|
add smoke detectors in duplex, job complete, final ok
|
ELE15-02467
| Permanent Service | 8/7/2015 | 8/10/2015 | 8/10/2015 11:08:36 AM | A | PASS |
|
|
relocation of service Phone #: ###-#### Inspection requested via web by Charles Davis duplex p/s u/g rec ok
|
ELE15-02159
| Electrical Rough-In | 8/6/2015 | 8/10/2015 | 8/10/2015 10:14:18 AM | A | PASS |
|
|
Potting, Bonding, and Underground conduits Inspection Phone #: ###-#### Inspection requested via web by Louis Keller Equipoyential bonding not completed at this time. Rough-in ok cover
|
ELE15-02458
| Electrical Rough-In | 8/7/2015 | 8/10/2015 | 8/10/2015 9:49:39 AM | A | FAIL |
|
|
Any questions please let me know, thx, TW. Phone #: ###-#### Inspection requested via web by Stephen Kren Not all insulation removed for inspection, (ceiling, foam seal back of service)
|
ELE15-02477
| Final | 8/7/2015 | 8/10/2015 | 8/10/2015 9:26:47 AM | A | FAIL |
|
|
I will have a technician there between 8:30-9:00, so he can check the service. If you have any questions, please call the office. Thank You. Phone #: ###-#### Inspection requested via web by Clay Morgan NEC 230.6(5) Unfused service feeders shall not be routed through walls of a building.NEC 250.56 Two ground rods
|