MEC18-03710
| Final | 8/9/2018 | 8/10/2018 | 8/10/2018 3:52:08 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Melissa Skinner- weather tight conduit for power ok- rtu final ok
|
MEC18-03907
| Final | 8/9/2018 | 8/10/2018 | 8/10/2018 3:14:22 PM | P | PASS |
|
|
can you please call when you are on the way. customers name is Ben and his # is ###-#### Phone #: ###-#### Inspection requested via web by Marisa Hone- A/C coil co ok
|
MEC18-03915
| Final | 8/9/2018 | 8/10/2018 | 8/10/2018 3:13:45 PM | P | PASS |
|
|
Please call on way: Chris ###-#### Phone #: ###-#### Inspection requested via web by Krista Boss- furnace ac coil co ok
|
MEC18-03758
| Final | 8/7/2018 | 8/10/2018 | 8/10/2018 2:40:26 PM | P | PASS |
|
|
Please call homeowner Cathy when in route to home ###-#### Phone #: ###-#### Inspection requested via web by Carolyn Rudd - furnace ac coil co ok
|
MEC17-05482
| Final | 8/9/2018 | 8/10/2018 | 8/10/2018 1:42:23 PM | P | PASS |
|
|
Our technician will be on sight around 10:00AM. Please call on way: Eric ###-#### Phone #: ###-#### Inspection requested via web by Krista Boss- Meet with Eric to check make up air back draft damper work properly- the make up air back draft damper functions properly- house was built in the early 70's and seems very loose and there is lots of infiltration so i dont think the exhaust will ever open the back draft damper- final ok
|
MEC18-03589
| Final | 8/7/2018 | 8/10/2018 | 8/10/2018 1:39:40 PM | P | FAIL |
|
|
Please call Jeff Morgan prior to inspection. ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette- cant find where condensate drain penetrates outside and turns down to the ground
|
MEC17-05201
| Mec-Aging Inspection | 8/10/2018 | 8/10/2018 | 8/10/2018 12:24:44 PM | | DONE |
|
|
called butlers hvac to schedule inspection
|
MEC18-03537
| Pressure Test | 8/9/2018 | 8/10/2018 | 8/10/2018 11:51:19 AM | A | PASS |
|
|
Gauge outside Phone #: ###-#### Inspection requested via web by Mary LaFayette 20lb gas pressure test ok- the gas flex in the crawl does still need to be strapped up( gas line is laying on the ground)- at final inspection i will need to see clearances on furnace flue. And manufactures installation instruction for the installed flue pipe
|
MEC18-03892
| Rough-in | 8/8/2018 | 8/10/2018 | 8/10/2018 11:23:47 AM | A | PASS |
|
|
CLINT ###-#### Phone #: ###-#### Inspection requested via web by Mike Almanza- fireplace R/I ok
|
MEC18-03852
| Rough-in | 8/9/2018 | 8/10/2018 | 8/10/2018 11:03:13 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Dan Otero- fireplace R/I ok
|
MEC18-03782
| Rough-in | 8/9/2018 | 8/10/2018 | 8/10/2018 10:42:37 AM | A | FAIL |
|
|
please call Jaman before going to give a heads up @ 208.697.4793 Phone #: ###-#### Inspection requested via web by Dan Otero - need to 2" clearances on top of vent pipe
|
MEC18-03919
| Conference | 8/9/2018 | 8/10/2018 | 8/10/2018 9:20:43 AM | A | DONE |
|
|
Please call soI have enough time to make it over there. Phone #: ###-#### Inspection requested via web by Geff Blecha
|
MEC18-03850
| Rough-in | 8/9/2018 | 8/10/2018 | 8/10/2018 8:52:04 AM | A | NR |
|
|
cover inspection - call cyrus Phone #: ###-#### Inspection requested via web by Brandon Sorensen- Room 113 still needs condensate ran before approve for ceiling cover
|
MEC18-01885
| Pressure Test | 8/9/2018 | 8/10/2018 | 8/9/2018 4:34:53 PM | A | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by Krista Boss Inspection cancelled from web by: Krista Boss
|
MEC18-01885
| Rough-in | 8/9/2018 | 8/10/2018 | 8/9/2018 4:34:52 PM | A | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by Krista Boss Inspection cancelled from web by: Krista Boss
|