ELE05-01066
| ELE-Aging Inspection | 8/11/2005 | 8/11/2005 | 8/16/2005 2:45:22 PM | | PASS |
|
|
|
ELE05-00014
| ELE-Aging Inspection | 8/11/2005 | 8/11/2005 | 8/15/2005 9:53:33 AM | | CANC |
|
|
still waiting for response back from contractor
|
ELE05-02733
| Final | 8/11/2005 | 8/11/2005 | 8/11/2005 4:08:44 PM | P | NR |
|
|
Phone #: ###-#### Internet Inspection Request from: Celinda Winters contractor corrected his part owner needs to correct his part of correction notice no final is to keep permit active, owner said he will have contractor make corrections told him he has one week to correct violations if ? call me 250.24(A)(1&5) GEC shall terminate at p/s , not sub panel and isolate grds and neutrals at sub panel, 110.3(B) use manufactures listed breakers only
|
ELE05-02023
| Final | 8/11/2005 | 8/11/2005 | 8/11/2005 3:43:00 PM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 8/11/2005 at 10:53:10 AM. ok survey posted called box fill island , replace arc fault breaker, will not trip
|
ELE05-02938
| Temporary Service | 8/11/2005 | 8/11/2005 | 8/11/2005 2:44:56 PM | P | FAIL |
|
|
roger ###-#### cor. posted called left message250.64(B) shall replace or protect #8 GEC use connector, secure t/s to pole and secure 220V recept in bracket, also put PM# on ID tag
|
ELE05-01049
| Electrical Rough-In | 8/11/2005 | 8/11/2005 | 8/11/2005 1:42:52 PM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 8/11/2005 at 9:17:42 AM. Contact: (208) r/i ok
|
ELE04-03015
| Final | 8/11/2005 | 8/11/2005 | 8/11/2005 1:08:14 PM | P | NR |
|
|
larry Note: swimming Pool - light compound ; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles see added r/i
|
ELE05-01566
| Final | 8/10/2005 | 8/11/2005 | 8/11/2005 12:15:18 PM | A | FAIL |
|
|
Phone #: ###-#### Internet Inspection Request from: Barbara Szurgot cor.posted called 110.3(B) use manufactures listed breakers only, 110.12(A) seal all unused KOs and breaker openings,BCC no violations to be retained, 408.36(F) back-fed devices shall be install as required
|
ELE05-02921
| Conference | 8/10/2005 | 8/11/2005 | 8/11/2005 11:12:22 AM | A | CANC |
|
|
please call 10 min prior to meet//isaac; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa called contractor he knew nothing about conference owner called it in on contractor's permit
|
ELE05-02003
| Conference | 8/9/2005 | 8/11/2005 | 8/11/2005 10:30:41 AM | A | DONE |
|
|
meeting at 9 am per jim storey
|
ELE05-02709
| Final | 8/10/2005 | 8/11/2005 | 8/11/2005 9:50:49 AM | A | PASS |
|
|
Re-Inspection After Corrections from; Phone #: ###-#### Internet Inspection Request from: Cathy Felin ok
|
ELE05-02864
| Final | 8/10/2005 | 8/11/2005 | 8/11/2005 8:55:43 AM | A | PASS |
|
|
duane; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa
|
ELE05-02880
| Rough-In Permanent Service | 8/10/2005 | 8/11/2005 | 8/11/2005 8:27:45 AM | A | PASS |
|
|
shane; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa r/i ok p/s o/h new ok
|
ELE05-01503
| ELE-Aging Inspection | 8/11/2005 | 8/11/2005 | 8/11/2005 8:06:01 AM | | PART |
|
|
stopped by WSUC
|
ELE05-02709
| Permanent Service | 8/11/2005 | 8/11/2005 | 8/11/2005 12:00:00 AM | A | PASS |
|
|
Re-Inspection After Corrections from; Phone #: ###-#### Internet Inspection Request from: Cathy Felin p/s o/h rec. ok
|
ELE04-03015
| Electrical Rough-In | 8/11/2005 | 8/11/2005 | 8/11/2005 12:00:00 AM | P | PART |
|
|
larry Note: swimming Pool - light compound ; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles encapsulation ok talked with larry about bonding metal parts around pool and spa
|