ELE05-02943
| Rough-In Permanent Service | 8/11/2005 | 8/11/2005 | 8/11/2005 4:45:16 PM | P | FAIL |
|
|
steve ###-#### called left message, left corr notice, 250.64(D) gec shall be via tap, not thru panel, 312.5 gec shall have abrasion protection,250.53(G) grd rod shall be flush or below ground, 300.4(A)(1) edge of bored holes shall be 1 1/4" from edge of framing member or use nailplate, 300.4(D) nm cable shall be 1 1/4" from edge of framing member, 210.52 (D) recpt shall be 3'-0" to edge of basin in bathroom, BCC job id sticker shall be posted
|
ELE05-02941
| Electrical Rough-In | 8/11/2005 | 8/11/2005 | 8/11/2005 4:38:00 PM | P | PASS |
|
|
dan miller cell ###-#### called contr, left message, left survey, 210.52(E) recpt shall be installed out back, 314.20 light boxes out back shall be flush with finished surface, 300.4(D) nm cable shall be 1 1/4" from edge of framing member, ok to cover
|
ELE05-01660
| Final | 8/11/2005 | 8/11/2005 | 8/11/2005 3:36:34 PM | P | PASS |
|
|
carrey --re-insp ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie ok to final
|
ELE05-01659
| Final | 8/11/2005 | 8/11/2005 | 8/11/2005 3:35:10 PM | P | PASS |
|
|
carrey --re-insp ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie ok to final
|
ELE05-02489
| Final | 8/11/2005 | 8/11/2005 | 8/11/2005 3:33:50 PM | P | CANC |
|
|
Scheduled by a contractor via Hello! on 8/11/2005 at 8:51:06 AM. Contact: ###-####. contr called and said nr
|
ELE05-02940
| Rough-In Permanent Service | 8/11/2005 | 8/11/2005 | 8/11/2005 2:59:26 PM | P | PASS |
|
|
chris ###-#### called contr, upper level to be unfinished, ric ok, p/s u/g n ok
|
ELE05-01605
| Rough-In Permanent Service | 8/11/2005 | 8/11/2005 | 8/11/2005 1:51:28 PM | P | CANC |
|
|
Early afternoon, if possible.; Phone #: ###-#### Internet Inspection Request from: Kathy Briggs see p/s
|
ELE05-02942
| Temporary Service | 8/11/2005 | 8/11/2005 | 8/11/2005 1:48:50 PM | P | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Kathy Briggs t/s u/g exst ok to final
|
ELE05-01605
| Conference | 8/11/2005 | 8/11/2005 | 8/11/2005 1:46:47 PM | P | DONE |
|
|
Early afternoon, if possible.; Phone #: ###-#### Internet Inspection Request from: Kathy Briggs review job
|
ELE05-01706
| Final | 8/10/2005 | 8/11/2005 | 8/11/2005 10:33:24 AM | A | FAIL |
|
|
Phone #: ###-#### Internet Inspection Request from: Lee VanSchoiack called left message ,250.8 approved grounding shall be used
|
ELE05-02391
| Permanent Service | 8/10/2005 | 8/11/2005 | 8/11/2005 10:31:57 AM | A | PASS |
|
|
service upgrade Internet Inspection Request from: Andy Rose called contr to abrasion protect gec and color phase wire, ok to final
|
ELE05-02840
| Final | 8/10/2005 | 8/11/2005 | 8/11/2005 9:49:28 AM | A | PASS |
|
|
brian; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa ok to final
|
ELE05-02450
| Final | 8/10/2005 | 8/11/2005 | 8/11/2005 9:45:47 AM | A | PASS |
|
|
brian; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa talked to elect about labels, gfci, branch ckt. signed card, ok to final
|
ELE05-02932
| Rough-In Permanent Service | 8/10/2005 | 8/11/2005 | 8/11/2005 9:04:11 AM | A | PASS |
|
|
###-#### - allen ric ok p/s u/g n ok
|
ELE05-02918
| Final | 8/10/2005 | 8/11/2005 | 8/11/2005 8:50:24 AM | A | PASS |
|
|
reinspection on A/C unit Internet Inspection Request from: Andy Rose corr made, clled contr to cover, ok to final
|
ELE05-02915
| Electrical Rough-In | 8/10/2005 | 8/11/2005 | 8/11/2005 8:37:27 AM | A | CANC |
|
|
Scheduled by a contractor via Hello! on 8/10/2005 at 12:02:28 PM. see rip
|
ELE05-02732
| Final | 8/10/2005 | 8/11/2005 | 8/11/2005 8:25:16 AM | A | PASS |
|
|
If any questions please call shane at ###-####. Thank You Internet Inspection Request from: Paul Young ok to final
|
ELE05-02783
| Electrical Rough-In | 8/9/2005 | 8/11/2005 | 8/11/2005 8:09:35 AM | A | PASS |
|
|
erika; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa ok to cover u/g shop to patio for 2 boxes only
|
ELE05-02783
| Conference | 8/9/2005 | 8/11/2005 | 8/11/2005 8:07:12 AM | A | DONE |
|
|
Scheduled by a contractor via Hello! on 8/9/2005 at 10:22:18 AM. talked about job, service and shop
|
ELE05-02915
| Rough-In Permanent Service | 8/11/2005 | 8/11/2005 | 8/11/2005 12:00:00 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 8/10/2005 at 12:02:28 PM. corrections made, ric ok, p/s u/g n ok
|
ELE05-01605
| Permanent Service | 8/11/2005 | 8/11/2005 | 8/11/2005 12:00:00 AM | P | PASS |
|
|
Early afternoon, if possible.; Phone #: ###-#### Internet Inspection Request from: Kathy Briggs p/s u/g n ok
|