ELE08-01218
| ELE-Aging Inspection | 8/11/2008 | 8/11/2008 | 8/15/2008 3:53:31 PM | | PASS |
|
|
|
ELE08-01421
| Final | 8/8/2008 | 8/11/2008 | 8/11/2008 4:20:36 PM | P | PASS |
|
|
martell Note: please call 1/2 hr prior to inspection to meet at apt Phone #: ###-#### no esc in project
|
ELE08-02227
| Electrical Rough-In | 8/8/2008 | 8/11/2008 | 8/11/2008 3:58:12 PM | A | PASS |
|
|
Chris Phone #: ###-#### no esc in project
|
ELE08-02079
| Electrical Rough-In | 8/11/2008 | 8/11/2008 | 8/11/2008 3:49:53 PM | P | PASS |
|
|
Need approval for bathroom ceiling cover Phone #: ###-#### Internet Inspection Request from: Lloyd Looney
|
ELE08-02241
| Temporary Service | 8/11/2008 | 8/11/2008 | 8/11/2008 3:29:25 PM | P | PASS |
|
|
Pole located off private drive on back of address Phone #: ###-#### Internet Inspection Request from: Phil Baker no esc in project T/S O/H Ok
|
ELE08-02245
| Rough-In Permanent Service | 8/11/2008 | 8/11/2008 | 8/11/2008 3:16:03 PM | P | CANC |
|
|
Randy Phone #: ###-#### Grounding electrode system shall be brought up to code prior to restoring service.
Boise city code 4-05-54 Code violations not to be retained. Splices in old knob and tube wiring shall be replaced because the fire was caused by improper splicing and 2 splices that I opened for inspection were improperly made. when knob and tube circuit is disconnected. P/S O/H R ok to set meter
|
ESC08-00327
| General Inspection | 8/11/2008 | 8/11/2008 | 8/11/2008 1:34:12 PM | P | PASS |
|
|
looks ok
|
ELE08-02239
| Electrical Rough-In | 8/11/2008 | 8/11/2008 | 8/11/2008 1:33:32 PM | P | PASS |
|
|
Jesse Phone #: ###-####
|
ELE08-02125
| Final | 8/11/2008 | 8/11/2008 | 8/11/2008 1:00:28 PM | P | PASS |
|
|
This Qwest power pedestal is complete and ready for permanent service. Thanks. Phone #: ###-#### Internet Inspection Request from: Clint Tate
|
ELE08-02125
| Permanent Service | 8/11/2008 | 8/11/2008 | 8/11/2008 1:00:04 PM | P | PASS |
|
|
This Qwest power pedestal is complete and ready for permanent service. Thanks. Phone #: ###-#### Internet Inspection Request from: Clint Tate P/S U/G N Ok
|
ELE08-02178
| Final | 8/11/2008 | 8/11/2008 | 8/11/2008 12:32:31 PM | P | PASS |
|
|
This Qwest power pedestal is complete and ready for permanent service. Thanks. Phone #: ###-#### Internet Inspection Request from: Clint Tate
|
ELE08-02178
| Permanent Service | 8/11/2008 | 8/11/2008 | 8/11/2008 12:32:17 PM | P | CANC |
|
|
This Qwest power pedestal is complete and ready for permanent service. Thanks. Phone #: ###-#### Internet Inspection Request from: Clint Tate P/S U/G N Ok
|
ELE08-01729
| Final | 8/8/2008 | 8/11/2008 | 8/11/2008 11:36:43 AM | A | PASS |
|
|
James Phone #: ###-#### ground bar reinstalled per mike's instructions.
|
ELE08-02231
| Permanent Service | 8/8/2008 | 8/11/2008 | 8/11/2008 11:15:14 AM | A | PASS |
|
|
Mike Phone #: ###-#### check water ground and size of feeders on next inspection. N /A ESC plan due to the small scope of excavation P/S U/G N ok to transfer power
|
ELE08-02165
| Conference | 8/8/2008 | 8/11/2008 | 8/11/2008 11:14:53 AM | A | PART |
|
|
Martha Phone #: ###-#### N /A ESC plan due to the small scope of excavation had phone conf with Doug he said he had had done a lot of wiring and I recommended that he get a book based on 2008 code and told him that we were using 2005 code for arc-fault in bedrooms only and explaned 210.52 general recep placement. he said he would call if he had any questions.
|
ELE08-01960
| Electrical Rough-In | 8/8/2008 | 8/11/2008 | 8/11/2008 10:35:01 AM | A | PART |
|
|
Level 5 wall only rough in. Jesse Phone #: ###-#### Internet Inspection Request from: jesse busack plans on site no esc in project
|
ELE08-01461
| Electrical Rough-In | 8/8/2008 | 8/11/2008 | 8/11/2008 10:05:21 AM | A | PART |
|
|
Ceiling Phone #: ###-#### Internet Inspection Request from: Kerri Hamilton section "E" 2nd floor ceiling ok no esc in project plans on site
|
ELE07-03280
| Electrical Rough-In | 8/11/2008 | 8/11/2008 | 8/11/2008 8:44:49 AM | A | PART |
|
|
Scheduled by a contractor via Hello! on 8/11/2008 at 7:02:58 AM. Contact: ###-####. no esc in project and plans on site walls anop
|