Inspections for the day of: Monday, August 11, 2014.
Number of inspections: 29
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMike Jordan
TitleBLD-COM/RES INSPECTOR
Phone #794-9473
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD14-02139 BLD-Footing8/11/20148/11/20148/12/2014 8:53:10 AMPCANC
BLD14-02141 BLD-Footing8/11/20148/11/20148/11/2014 4:18:33 PMPPASS
request 3pm // Andy Phone #: ###-####
BLD14-02137 BLD-Footing8/11/20148/11/20148/11/2014 4:18:15 PMPPASS
request 3pm // Andy Phone #: ###-####
BLD14-01098 BLD-Framing/Rough-in8/11/20148/11/20148/11/2014 3:52:51 PMPPASS
Jeff Phone #: ###-####
BLD13-03540 BLD-Wall Bracing8/11/20148/11/20148/11/2014 3:15:20 PMPPASS
2nd floor shear Phone #: ###-#### Inspection requested via web by Brian Stark
BLD13-03545 BLD-Wall Bracing8/11/20148/11/20148/11/2014 3:15:03 PMPPASS
2nd floor shear Phone #: ###-#### Inspection requested via web by Brian Stark
BLD13-03547 BLD-Wall Bracing8/11/20148/11/20148/11/2014 3:14:44 PMPPASS
2nd floor shear Phone #: ###-#### Inspection requested via web by Brian Stark
BLD13-03546 BLD-Wall Bracing8/11/20148/11/20148/11/2014 3:14:27 PMPPASS
2nd floor shear Phone #: ###-#### Inspection requested via web by Brian Stark
BLD13-02058 BLD-Final8/11/20148/11/20148/11/2014 3:02:51 PMPNR
Phone #: ###-#### Inspection requested via web by Brian Stark. Needs mech. final.
BLD13-02057 BLD-Final8/11/20148/11/20148/11/2014 2:46:32 PMPPASS
Please call brian prior Phone #: ###-#### Inspection requested via web by Brian Stark
BLD13-02057 DOC - Permit Finaled8/11/20148/11/20148/11/2014 2:46:01 PMPPASS
BLD13-03537 BLD-Energy code compliance8/8/20148/11/20148/11/2014 2:38:28 PMPPASS
Phone #: ###-#### Inspection requested via web by Brian Stark
BLD13-03536 BLD-Energy code compliance8/8/20148/11/20148/11/2014 2:37:38 PMPPASS
Phone #: ###-#### Inspection requested via web by Brian Stark
BLD14-00211 BLD-Wall Bracing8/11/20148/11/20148/11/2014 2:01:55 PMPFAIL
Richard Phone #: ###-####. Floor to floor straps per RFI 0008. Missing 2 MSTC28 straps.
BLD14-00213 BLD-Wall Bracing8/11/20148/11/20148/11/2014 1:59:09 PMPFAIL
Richard Phone #: ###-####. 1st floor shear walls, nailing overspaced.
BLD13-03543 BLD-Wall Bracing8/7/20148/11/20148/11/2014 12:02:49 PMAPASS
Whole building shear Phone #: ###-#### Inspection requested via web by Brian Stark
BLD13-03544 BLD-Wall Bracing8/7/20148/11/20148/11/2014 12:02:30 PMAPASS
Whole building shear Phone #: ###-#### Inspection requested via web by Brian Stark
BLD13-03542 BLD-Wall Bracing8/7/20148/11/20148/11/2014 12:02:17 PMAPASS
Whole building shear Phone #: ###-#### Inspection requested via web by Brian Stark
BLD13-03541 BLD-Wall Bracing8/7/20148/11/20148/11/2014 12:02:02 PMAPASS
Whole building shear Phone #: ###-#### Inspection requested via web by Brian Stark
BLD14-01970 BLD-Final8/8/20148/11/20148/11/2014 11:22:21 AMADONE
Phone #: ###-#### Inspection requested via web by Phillip Bauer. All work appeared to be done in accordance with local codes and ordinances.
BLD14-01970 DOC - Permit Finaled8/11/20148/11/20148/11/2014 11:21:33 AMPPASS
BLD13-03538 BLD-Framing/Rough-in8/7/20148/11/20148/11/2014 10:45:33 AMAFAIL
Phone #: ###-#### Inspection requested via web by Brian Stark. Complete 2hr. firewal at attick both sides, Install shear blockingabove slider 2nd. floor. Nail off all simpson hangars 1st. floor. Add additional stud under 2ply LVL at stairs 2nd. floor. fireblock 3rd floor tub at floor. ok to insulate. correction notice posted.
BLD13-03539 BLD-Framing/Rough-in8/7/20148/11/20148/11/2014 10:42:01 AMAFAIL
Phone #: ###-#### Inspection requested via web by Brian Stark. fireblock 3rd floor tub at floor. ok to insulate.
BLD14-01536 BLD-Ceiling Grid Inspection8/8/20148/11/20148/11/2014 9:01:57 AMAPASS
craig Phone #: ###-####
BLD14-01103 BLD-Foundation8/7/20148/11/20148/11/2014 8:35:03 AMADONE
Manuel Phone #: ###-####
BLD14-01105 BLD-Foundation8/7/20148/11/20148/11/2014 8:34:46 AMADONE
Manuel Phone #: ###-####
BLD13-03537 BLD-Framing/Rough-in8/8/20148/11/20148/8/2014 12:06:49 PMACANC
Phone #: ###-#### >> Inspection requested via web by Brian Stark Inspection cancelled from web by: Brian Stark
BLD13-03536 BLD-Energy code compliance8/7/20148/11/20148/8/2014 11:58:19 AMACANC
Phone #: ###-#### >> Inspection requested via web by Brian Stark Inspection cancelled from web by: Brian Stark
BLD13-03537 BLD-Energy code compliance8/7/20148/11/20148/8/2014 11:58:11 AMACANC
Phone #: ###-#### >> Inspection requested via web by Brian Stark Inspection cancelled from web by: Brian Stark