Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE20-01892 Electrical Rough-In8/11/20208/11/20208/11/2020 3:22:56 PMPPASS
Phone #: ###-#### Inspection requested via web by Kerri Hamilton Grid rough in ok cover.
ELE19-00601 Electrical Rough-In8/11/20208/11/20208/11/2020 2:15:26 PMPPASS
Pool Bonding. Tyson is the contact. Phone #: ###-#### Inspection requested via web by Buster Pool perimeter, ladder, hoop, handicap chair bonds rough in ok cover.
ELE20-01794 Final8/11/20208/11/20208/11/2020 1:42:04 PMPPART
a partial final on the first floor we will be checking the cubicle farm conference rooms and work lab call Tyson for questions 2082516476 Phone #: ###-#### Inspection requested via web by Shane Lott Informed of operating change over starting end of business 8-13-20. Informed of lighting system commissioning report required by the registered sesign professional prior to final. IECC C408.3.1 Lighting controls being covered by cubicals shall be moved or other solution prior to final. Prechecked cubicals, and conference rooms on level 1..... OK
ELE20-02780 Rough-In Permanent Service8/10/20208/11/20208/11/2020 11:26:37 AMAPASS
Phone #: ###-#### Inspection requested via web by Rodney Monroe Rough in ok cover p/s u/g n ok
ELE20-02460 Electrical Rough-In8/10/20208/11/20208/11/2020 10:28:42 AMAPASS
Potting and equipotential (swimming pool) Phone #: ###-#### Inspection requested via web by Kevin Koomler Rough in ok cover
ELE20-02748 Rough-In Permanent Service8/11/20208/11/20208/11/2020 10:02:30 AMAFAIL
Phone #: ###-#### Inspection requested via web by Therrin Robertson 250.92- Non current carrying metal parts of furnace shall be connected to an equipment grounding conductor. 300.4- Wher NM cable s run thru bored holes that do not maintain 1 1/4" from framing surface they shall be protected form damage by nail plates. Several thru out. 300.15- Smoke wire level 1 shall terminate in a box. 314.17- Where NM enters furnace it shall be protected from abrasion by a bushing. 314.17(C)- Up master bath vanity can NM sheathing shall enter box a minimum of 1/4".
ELE20-02749 Rough-In Permanent Service8/11/20208/11/20208/11/2020 9:56:36 AMAPASS
Phone #: ###-#### Inspection requested via web by Therrin Robertson Rough in ok cover p/s u/g n ok
ELE20-02604 Electrical Rough-In8/10/20208/11/20208/11/2020 9:18:10 AMAPASS
Underslab Phone #: ###-#### Inspection requested via web by Bryan Atkins X-ray under slab rough in ok cover