Inspections for the day of: Monday, August 12, 2013.
Number of inspections: 8
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE13-02133 Rough-In Permanent Service8/9/20138/12/20138/12/2013 2:21:45 PMPNR
Phone #: ###-#### >> Inspection requested via web by Darryn Coburn met contractor, looked at some activities, will recall
ELE13-02144 Temporary Service8/12/20138/12/20138/12/2013 1:28:42 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Bob Glenn t/s u/g n ok
ELE13-02145 Temporary Service8/12/20138/12/20138/12/2013 1:04:43 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Bob Glenn t/s u/g n ok
ELE13-01999 Electrical Rough-In8/12/20138/12/20138/12/2013 12:22:36 PMPFAIL
martin Phone #: ###-#### called, no answer, left correction notice, shall staple nm within 8" of box, shall provide nailplates, shall provide 1 1/4" protection of nm cable on studs, shall staple staple nm cable out of panel
ELE13-02143 Temporary Service8/11/20138/12/20138/12/2013 10:33:48 AMAFAIL
Phone #: ###-#### >> Inspection requested via web by Neal Rumsey called, shall provide working clearance per NEC 110.26(A)(2)
ELE12-03075 Final8/11/20138/12/20138/12/2013 10:15:13 AMAFAIL
Phone #: ###-#### >> Inspection requested via web by Darrin Bybee called, shall add receptacle downstairs bedroom entry per NEC 210.52, shall label panels per NEC 408, pool lights shall be gfci protected, shall provide correct breakers in pool area panel
ELE13-02139 Permanent Service8/9/20138/12/20138/12/2013 8:54:40 AMAPASS
Contact: Garrett Collins Phone #: ###-#### >> Inspection requested via web by Deb Gooden p/s u/g n ok
ELE13-01531 Final8/11/20138/12/20138/12/2013 8:36:51 AMAPASS
garage code 9045 Phone #: ###-#### >> Inspection requested via web by Neal Rumsey ok final