Inspections for the day of: Tuesday, August 12, 2014.
Number of inspections: 21
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorChad Schwendiman
TitleMEC-INSPECTOR
Phone #780-9549
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC14-03462 Rough-in8/12/20148/12/20148/12/2014 4:32:22 PMPPASS
5730755 bj >> Inspection requested via web by william kerwin
MEC13-02192 Final8/12/20148/12/20148/12/2014 4:08:34 PMPPASS
Call Frank with access issues, ###-####. Thanks Phone #: ###-#### >> Inspection requested via web by Allie Courter
MEC14-03304 Final8/11/20148/12/20148/12/2014 3:40:59 PMPPASS
Meet home owner at 3:00
MEC14-03441 Final8/12/20148/12/20148/12/2014 3:11:51 PMPPASS
Please call LL, Jeffrey prior to arrival ###-####. Phone #: ###-#### >> Inspection requested via web by James Staley
MEC14-03096 Final8/12/20148/12/20148/12/2014 2:33:01 PMPPASS
Phone #: ###-#### >> Inspection requested via web by April Thomas
MEC14-03216 Rough-in8/12/20148/12/20148/12/2014 1:49:42 PMPFAIL
###-#### Phone #: ###-#### >> Inspection requested via web by Joe Bertwell - NEED TO SLEEVE GAS TIGHT WHERE IT PENETRATES THE FIREPLACE, NEED TO INSTALL CO2 SENSORS, NEED TO DO GAS TEST.
MEC14-03437 Pressure Test8/11/20148/12/20148/12/2014 1:27:18 PMPFAIL
Adam: ###-#### Phone #: ###-#### >> Inspection requested via web by Frank Marturello - 20LB GAS PRESSURE FAIL. 5LB FLUE PRESSURE OKAY
MEC14-03437 Rough-in8/11/20148/12/20148/12/2014 1:26:28 PMPPASS
Adam: ###-#### Phone #: ###-#### >> Inspection requested via web by Frank Marturello
MEC14-03419 Final8/11/20148/12/20148/12/2014 12:15:21 PMPCANC
Phone #: ###-#### >> Inspection requested via web by April Thomas - NOT READY
MEC14-00975 Rough-in8/11/20148/12/20148/12/2014 11:34:21 AMPPART
1st floor cover inspection please Phone #: ###-#### >> Inspection requested via web by GREGORY ANDERSEN - 1ST FLOOR CEILING OKAY TO COVER.
MEC14-03285 Final8/11/20148/12/20148/12/2014 10:49:14 AMAFAIL
meet home owner at 10:00 - 5LB FLUE PRESSURE FAIL, NEED TO DO A PRESSURE TEST ON PVC WATER HEATER FLUE ALSO.
MEC14-03438 Final8/11/20148/12/20148/12/2014 10:20:00 AMAPASS
call ahead to Orville Boon @ ###-####-7137 for AM Final Inspection Phone #: ###-#### >> Inspection requested via web by Bailey Esposito
MEC13-02497 Mec-Aging Inspection8/12/20148/12/20148/12/2014 10:04:45 AM PASS
MEC13-02497 Final8/12/20148/12/20148/12/2014 10:04:17 AMAPASS
This should have been finaled
MEC14-03442 Final8/12/20148/12/20148/12/2014 9:56:09 AMPCANC
Please call Pat prior to arrival home: ###-#### or cell: ###-####. Phone #: ###-#### >> Inspection requested via web by James Staley Inspection cancelled from web by: James Staley
MEC14-03105 Final8/11/20148/12/20148/12/2014 9:35:15 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Mary LaFayette
MEC13-02492 Mec-Aging Inspection8/12/20148/12/20148/12/2014 9:19:42 AM CANC
NO CALLS
MEC14-03096 Rough-in8/11/20148/12/20148/12/2014 9:10:10 AMAFAIL
Phone #: ###-#### >> Inspection requested via web by April Thomas - NEED TO INSTALL TRANSFER GRILLS IN BASEMENT BEDROOMS
MEC14-03432 Final8/11/20148/12/20148/12/2014 8:35:41 AMAFAIL
It''s ready anytime, A/C is on the Right side of home Phone #: ###-#### >> Inspection requested via web by Floyd Floyd Peek - NEED TO INSTALL A DISCONNECT OUT SIDE AT A/C LOCATION. ELECTRICAL FLEX TO A/C NEEDS TO BE A WATER TIGHT FLEX.
MEC13-02192 Final8/11/20148/12/20148/12/2014 8:24:54 AMAFAIL
Call Frank with access issues, ###-####. Phone #: ###-#### >> Inspection requested via web by April Thomas - protection post still not installed
MEC14-03078 Final8/11/20148/12/20148/11/2014 2:28:36 PMACANC
Homeowner, Don Blackwood, ###-#### >> Inspection requested via web by Mary LaFayette Inspection cancelled from web by: Mary LaFayette