ELE13-00908
| ELE-Aging Inspection | 8/12/2016 | 8/12/2016 | 8/12/2016 2:54:03 PM | | PASS |
|
|
Waiting on owner
|
ELE13-00039
| ELE-Aging Inspection | 8/12/2016 | 8/12/2016 | 8/12/2016 2:53:09 PM | | PASS |
|
|
Waiting on contractor
|
ELE12-02853
| ELE-Aging Inspection | 8/12/2016 | 8/12/2016 | 8/12/2016 2:52:31 PM | | PASS |
|
|
Waiting on contractor
|
ELE15-01348
| Rough-In Permanent Service | 8/12/2016 | 8/12/2016 | 8/12/2016 2:51:53 PM | P | PASS |
|
|
Annex HV XFMR 5, 1600 amp MAIN MSSE, 1600 amp Buss Duct MSSE,Grounding Electrode System, Main Bonding Jumper. Want to Energize , Doors and Panic Hwd Annex Phone #: ###-#### Inspection requested via web by Tom Betty SWHQ stair #2 levels6-9, annex core walls level 5 Phone #: ###-#### Inspection requested via web by Brandon Robinson Wall rough in as noted ok cover. Annex service ok to energize for temp 200 amp power only. Door issues with electical room.
|
ELE15-01348
| Electrical Rough-In | 8/12/2016 | 8/12/2016 | 8/12/2016 2:51:14 PM | P | FAIL |
|
|
Annex HV XFMR 5, 1600 amp MAIN MSSE, 1600 amp Buss Duct MSSE,Grounding Electrode System, Main Bonding Jumper. Want to Energize , Doors and Panic Hwd Annex Phone #: ###-#### Inspection requested via web by Tom Betty NEC 110.26(C)(2)- For electrical equipment rated 1200 amps or more and 6 ft wide or more doors for egress shall be at each end of work space. Doors shall remain. NEC 110.26(C)(3)- Doors located within 25' of electrical gear rated 800 amps or more shall have panic hardware. Doors shall open out in direcion of egress. If correction not complete by 8-19-16 step will be taken to disconnect power from electrical gear in rooms OBG 121 and 122.
|
ELE16-01838
| Electrical Rough-In | 8/12/2016 | 8/12/2016 | 8/12/2016 2:20:23 PM | P | CANC |
|
|
SWHQ stair #2 levels6-9, annex core walls level 5 Phone #: ###-#### Inspection requested via web by Brandon Robinson Wrong permit requested needed core and shell permit
|
ELE16-01477
| Final | 8/12/2016 | 8/12/2016 | 8/12/2016 1:18:05 PM | P | PART |
|
|
Partial final in Deli area only call cody for questions Phone #: ###-#### Inspection requested via web by Shane Lott Deli temp occupy OK
|
ELE16-02623
| Electrical Rough-In | 8/11/2016 | 8/12/2016 | 8/12/2016 11:45:05 AM | A | PASS |
|
|
Uffer ground inspection. Contact Craig Timmons Phone #: ###-#### Inspection requested via web by Cathy Duchek Concrete encase electrode rough in ok cover.
|
ELE16-02410
| Final | 8/11/2016 | 8/12/2016 | 8/12/2016 11:03:35 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Dean Gernaat Final ok
|
ELE15-01617
| Electrical Rough-In | 8/11/2016 | 8/12/2016 | 8/12/2016 10:32:00 AM | A | NH |
|
|
Phone #: ###-#### Inspection requested via web by Kerri Hamilton Called contact no answer left message. Must Recall
|
ELE15-02740
| Final | 8/11/2016 | 8/12/2016 | 8/12/2016 10:16:21 AM | A | PART |
|
|
Seth ###-#### Check switches have been removed. Switches romoved. Temp occupancy OK
|
ELE16-02578
| Conference | 8/12/2016 | 8/12/2016 | 8/12/2016 9:50:59 AM | P | DONE |
|
|
Discussed underground, expansion joint, garage receptacles tamper, GFCI protection and all electrical above 18", and required work space for sub-panel.
|
ELE16-01477
| Final | 8/11/2016 | 8/12/2016 | 8/12/2016 9:11:45 AM | A | FAIL |
|
|
PARTIAL FINAL ** for DELI area only** in the morning if possible Call cody for questions ###-#### Phone #: ###-#### Inspection requested via web by Shane Lott Building permit lists deli area as meat and seafood area so all of area shall comply with 210.8- all 120 volt receptacle outlets shall have GFCI protection. Back area and north display case receptacles.
|