Inspections
/
Inspector Activity
Inspections for the day of:
Friday, August 12, 2016
.
Number of inspections:
25
Percentage of inspections complete:
100 %
Percentage of inspections not complete:
0 %
Contact Information
Inspector
Ben Livingston
Title
MEC-COM/RES INSPECTOR
Phone #
576-1208
Permit Number
Description
Received
Requested
Completed
AM/PM
Disposition
MEC16-03649
Final
8/12/2016
8/12/2016
8/15/2016 7:10:12 AM
P
PASS
Would like late PM and a call when on way. Thank you! Phone #: ###-#### Inspection requested via web by Xanti Berria
MEC16-03653
Final
8/11/2016
8/12/2016
8/12/2016 3:40:39 PM
P
PASS
Please call Kelsey at ###-#### with a 30 minute heads up. Phone #: ###-#### Inspection requested via web by David or K Cole
MEC16-03330
Rough-in
8/9/2016
8/12/2016
8/12/2016 2:52:41 PM
P
PASS
Please call Daryl with any questions. Phone #: ###-#### Inspection requested via web by Diane Day-
add more dove tails to ins. shield on bvent
MEC16-03330
Pressure Test
8/9/2016
8/12/2016
8/12/2016 2:51:40 PM
P
PASS
Please call Daryl with any questions. Phone #: ###-#### Inspection requested via web by Diane Day- 20lb gas
MEC16-03597
Rough-in
8/12/2016
8/12/2016
8/12/2016 2:01:09 PM
P
FAIL
Oleg Phone #: ###-####-
need approved manual j on site for rough in inspection
MEC16-03597
Pressure Test
8/12/2016
8/12/2016
8/12/2016 2:00:03 PM
P
PASS
Oleg Phone #: ###-####-
20lb gas, 5lb flue
MEC16-03597
Rough-in
8/12/2016
8/12/2016
8/12/2016 1:56:48 PM
P
PASS
Oleg-fireplace Phone #: ###-####-
fireplace
MEC16-03411
Final
8/9/2016
8/12/2016
8/12/2016 1:24:37 PM
P
PASS
Would like early PM and a call when on way. Thank you! Phone #: ###-#### Inspection requested via web by Xanti Berria
MEC16-03648
Rough-in
8/12/2016
8/12/2016
8/12/2016 1:13:25 PM
P
PASS
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN
equipment not set
MEC16-03591
Final
8/9/2016
8/12/2016
8/12/2016 11:04:43 AM
A
NH
We are requesting a final inspection for replacing a 50gallon gas water heater. Contact Russ McNally : ###-#### Phone #: ###-#### Inspection requested via web by Rusty Karel
MEC16-03629
Final
8/12/2016
8/12/2016
8/12/2016 10:49:21 AM
A
FAIL
Phone #: ###-#### Inspection requested via web by Scott Wickstrom-
need to add water heater to permit,
need c o alarm by bedrooms,
water heater flue needs more grade up,
gas to water heater needs cediment trap
MEC16-03300
Rough-in
8/12/2016
8/12/2016
8/12/2016 10:26:41 AM
A
PART
This inspection is a partial to inspect all bath fans for all bathrooms wich are ran thru floor joists from upper level...so framers can close floor on the upper level and continue framing...thanks
Call chet 20 min advance so he can meet inspector there and open door for him there''s no people at this house. Phone #: ###-#### Inspection requested via web by Manuel Canto-
5 bath fans, 4 floor vents on 2nd floor ok for cover
MEC16-03648
Rough-in
8/11/2016
8/12/2016
8/12/2016 9:42:31 AM
A
FAIL
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN-
need 1" clearance for bvent
MEC16-03648
Pressure Test
8/11/2016
8/12/2016
8/12/2016 9:41:34 AM
A
PASS
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN-
20lb gas, 5lb flue
MEC16-03496
Rough-in
8/11/2016
8/12/2016
8/12/2016 9:01:12 AM
A
PASS
Clint ###-#### Phone #: ###-#### Inspection requested via web by Jason Robinson
MEC16-03309
Rough-in
8/9/2016
8/12/2016
8/12/2016 8:43:37 AM
A
PASS
Phone #: ###-#### Inspection requested via web by dannyel chaloupka
MEC16-03309
Pressure Test
8/9/2016
8/12/2016
8/12/2016 8:43:19 AM
A
PART
Phone #: ###-#### Inspection requested via web by dannyel chaloupka-
20lb gas ok,
need to retest flue
MEC15-04877
Mec-Aging Inspection
8/12/2016
8/12/2016
8/12/2016 8:08:25 AM
PEND
MEC15-04877
DOC - Permit Expired
8/12/2016
8/12/2016
8/12/2016 8:08:11 AM
P
PASS
MEC14-02068
Mec-Aging Inspection
8/12/2016
8/12/2016
8/12/2016 8:07:17 AM
PEND
MEC14-02068
DOC - Permit Expired
8/12/2016
8/12/2016
8/12/2016 8:07:00 AM
P
PASS
MEC15-03158
Mec-Aging Inspection
8/12/2016
8/12/2016
8/12/2016 8:05:48 AM
PEND
MEC15-03158
DOC - Permit Expired
8/12/2016
8/12/2016
8/12/2016 8:05:26 AM
P
PASS
MEC15-02949
Mec-Aging Inspection
8/12/2016
8/12/2016
8/12/2016 8:03:54 AM
PEND
MEC15-02949
DOC - Permit Expired
8/12/2016
8/12/2016
8/12/2016 8:03:32 AM
P
PASS