Inspections for the day of: Wednesday, August 13, 2008.
Number of inspections: 20
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorClint A Smith
TitleEROSION CONTROL INSPECTOR
Phone #794-8996
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC06-00271 Aging Inspection8/13/20088/13/20088/15/2008 2:32:28 PM DEFR
Moved to a site final.
ESC08-00225 General Inspection8/13/20088/13/20088/14/2008 2:15:38 PMPPART
Spoke with RP over keeping the parking lot swept up. No room for a costruction entrance so they will have to rely on sweeping. Doing a good job of it though.
CAS
ESC08-00504 General Inspection8/13/20088/13/20088/13/2008 3:31:15 PMPPASS
No issues present.
CAS
ESC08-00556 General Inspection8/13/20088/13/20088/13/2008 3:24:35 PMPFAIL
Spoke with the RP. Maint tain the perimeter bmp's at the front of the lot. Will re-inspect on 8/19/08
CAS
ESC07-00751 Random Inspection8/13/20088/13/20088/13/2008 3:21:10 PMPPASS
ESC07-01112 BMP Violation8/13/20088/13/20088/13/2008 3:20:53 PMPFAIL
Left a message with the RP. Need to maintain sediment BMP's along the front of lot. Clean gutter pas infront of lot. Pick up trash debris through out the lot. Install additional silt fenc on the north east side of the lot where the slope is disturbed and no protection from erosion is at. Will re-inspect on 8/19/008
CAS
ESC08-00603 Tracking Control8/13/20088/13/20088/13/2008 3:14:56 PMPFAIL
Need to clean up tracking off of Arrow crest Way. Left a message for RP at his company office. Will re-inspect on 8/15/08
CAS
ESC04-00615 Site Final8/13/20088/13/20088/13/2008 2:56:21 PMPPASS
ESC05-01000 Site Final8/13/20088/13/20088/13/2008 2:55:36 PMPPASS
ESC05-01424 Site Final8/13/20088/13/20088/13/2008 2:55:03 PMPPASS
ESC06-01181 Site Final8/13/20088/13/20088/13/2008 2:54:10 PMPPASS
ESC08-00513 General Inspection8/13/20088/13/20088/13/2008 2:32:19 PMPPART
Need to add sediment control at the fron of the lot along the street. Will re-inspect on 5/19/08. Spoke with Rp over the issue.
CAS
ESC08-00624 BMP Violation8/7/20088/13/20088/13/2008 2:11:45 PMAPASS
Issues with prior inspection have been resolved and corrected.
CAS
ESC08-00508 Random Inspection8/13/20088/13/20088/13/2008 1:49:22 PMPPART
Left a message with RP. Prior to next concrete pour date, the concrete wahout must be lined with either 2 layer of 6 mil or 1 layer of 10 mil plastic due to the soil type and the distance to the Boise River. Will re-inspect on 8/18/08.
CAS
ESC07-01561 BMP Violation8/12/20088/13/20088/13/2008 11:07:32 AMAFAIL
Refer to ESC08-00233
ESC08-00093 General Inspection8/12/20088/13/20088/13/2008 9:48:56 AMAPASS
No issues present.
ESC08-00224 General Inspection8/12/20088/13/20088/13/2008 9:46:51 AMAFAIL
Refer to ESC08-00233
ESC08-00575 Tracking Control8/13/20088/13/20088/13/2008 9:12:59 AMAPASS
Cleaned up tracking from the day prior. Will be closing off the entrance to the site and will be using an alternate access point for a short period of time. THen they will go back to the entrance and will be stabilized. Street sweeping will be used in the period of time if any tracking occurs through the duration of using the alternate access point.
Will re-inspect on 8/14/08
CAS
ESC08-00139 General Inspection8/13/20088/13/20088/13/2008 9:09:25 AMAPART
Told Rp to clean up spoil piles on site of concrete.
CAS
ESC08-00512 General Inspection8/6/20088/13/20088/12/2008 11:10:50 AMAPART
WEnt over the project with Scott (RP) and discussed the areas of concerns and how inspections will be handled. We are making the post another ESC sign at another lotcation on the site due to the size of the project. Will re-inspect on 8/15/08for more bmp's that are in the process of being installed.
CAS