Inspections for the day of: Wednesday, August 13, 2014.
Number of inspections: 16
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorDaryl DeGrange
TitleELE-INSPECTION SUPV
Phone #794-1379
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
GCE14-00115 GCE-Rough-In Permanent Service8/13/20148/13/20148/13/2014 2:08:27 PMPDONE
see final
ELE12-02803 Final8/13/20148/13/20148/13/2014 2:07:59 PMPPASS
ALLSTATE UL listed wall sign final ok
GCE14-00116 GCE-Permanent Service8/13/20148/13/20148/13/2014 1:33:39 PMPDONE
Daniel ###-####
correction done, p/s u/g n ok
GCE14-00066 GCE-Final8/13/20148/13/20148/13/2014 1:28:44 PMPPASS
(Mandatory Inspection)Ron ###-####
correction done
ELE14-02206 Final8/12/20148/13/20148/13/2014 1:28:03 PMPNR
Inspection requested via web by Rowdy Monroe not ready for final at this time
ELE14-02206 Rough-In Permanent Service8/13/20148/13/20148/13/2014 1:27:03 PMPPASS
Inspection requested via web by Rowdy Monroe rough-in p/s u/g n ok
ELE14-02113 Electrical Rough-In8/13/20148/13/20148/13/2014 12:45:43 PMPPASS
If you have any questions, please call Clay ###-####. Thank You. Phone #: ###-#### Inspection requested via web by Clay Morgan rough-in ok cover master bedroom/bath addition
ELE14-02227 Permanent Service8/13/20148/13/20148/13/2014 11:09:19 AMPFAIL
Gary Phone #: ###-#### NEC 200.2(B) The continuity of the grounded conductor shall not depend on a connection to a metal enclosure. NEC 210.7(B) common trip for edison branch circuits Termination of neutral conductors, one per lug. shall not be terminated in same lug with grounding conductor. Bond metal raceway where unfused service conductors enter
ELE13-03516 Final8/12/20148/13/20148/13/2014 10:04:12 AMANH
Lock box on back of house, combo is 4320 Phone #: ###-#### Inspection requested via web by Brad Girard No access
ELE14-02215 Temporary Service8/12/20148/13/20148/13/2014 9:48:20 AMAPASS
Phone #: ###-#### Inspection requested via web by Darryn Coburn t/s u/g n ok
ELE12-01568 ELE-Aging Inspection8/13/20148/13/20148/13/2014 9:34:49 AM DONE
attached notice to front door about ageing permit
ELE14-02224 Electrical Rough-In8/13/20148/13/20148/13/2014 9:06:10 AMAPASS
Call Ben if any questions Phone #: ###-#### Inspection requested via web by Ben Archibald Rough-in ok cover
ELE14-02224 Permanent Service8/13/20148/13/20148/13/2014 9:05:35 AMPPASS
Call Ben if any questions Phone #: ###-#### Inspection requested via web by Ben Archibald p/s u/g n ok
ELE14-02224 Temporary Service8/13/20148/13/20148/13/2014 9:04:56 AMACANC
Call Ben if any questions Phone #: ###-#### Inspection requested via web by Ben Archibald
ELE14-01641 Electrical Rough-In8/12/20148/13/20148/13/2014 8:44:55 AMAPASS
Need master bath floor heat inspection approval for cover. Phone #: ###-#### Inspection requested via web by Jerry Moore Rough-in ok cover CSA Listed heat cable
ELE14-01779 Final8/12/20148/13/20148/13/2014 8:33:45 AMAPART
Temp occupancy needed in am Phone #: ###-#### Inspection requested via web by JENNY EMEL Temporay occuancy ok No cubicles on site