Inspections for the day of: Monday, August 13, 2018.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorTom Saunders
TitleELE-INSPECTOR
Phone #208-794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE13-01474 ELE-Aging Inspection8/13/20188/13/20188/21/2018 7:43:39 AM FAIL
contractor need final scheduled and get access
ELE18-03066 Final8/13/20188/13/20188/13/2018 2:42:54 PMPPASS
Harlod Phone #: ###-####...job complete...ok to final
ELE18-03066 Electrical Rough-In8/13/20188/13/20188/13/2018 2:42:27 PMPPASS
Harlod Phone #: ###-####...PVC used to wire in outlet on surface of garage wall...ok
ELE18-03066 Conference8/13/20188/13/20188/13/2018 2:41:13 PMPPASS
Harlod Phone #: ###-####...wiring in 240v 20A circuit for heater...homeowner competent
ELE18-03047 Electrical Rough-In8/10/20188/13/20188/13/2018 2:39:52 PMPPASS
Code for keypad on back door is 71284* in case its locked up. Phone #: ###-#### Inspection requested via web by Greg Traudt...new walls ok to cover...ceiling fished in and surface mounted fixtures
ELE18-02749 Final8/13/20188/13/20188/13/2018 1:07:51 PMPPASS
As discussed in the previous rough-in inspection, I have completed the installation of the 220v, 15 amp electrical line for an outdoor AC condensing unit. Please call me (###-####) or Tona (###-####), 25 minutes before arriving. Phone #: ###-#### Inspection requested via web by Nicole Yogerst...
fused disconnect with 15A fuses...ok to final
ELE18-02749 Electrical Rough-In8/12/20188/13/20188/13/2018 1:07:11 PMPPASS
As discussed in the previous rough-in inspection, I have completed the installation of the 220v, 15 amp electrical line for an outdoor AC condensing unit. Please call me (###-####) or Tona (###-####), 25 minutes before arriving. Phone #: ###-#### Inspection requested via web by Nicole Yogerst...
rough ok...sealtite to fused disconnect...14thhn used 15A circuit
ELE18-03058 Rough-In Permanent Service8/12/20188/13/20188/13/2018 12:42:16 PMAFAIL
CAN BE AM OR PM whichever works better for you. Phone #: ###-#### Inspection requested via web by Cindie Swaim...
1..ground rod shall be added at shop
2..underground to shop needs verified of depth...no inspection of underground ever done..sections shall be unbarried

walls and ceiling of shop ok to cover
ELE18-02945 Final8/13/20188/13/20188/13/2018 10:08:45 AMAPASS
Call with any questions or concerns. Phone #: ###-#### Inspection requested via web by Garrett Collins...ok to final
ELE18-01894 Final8/10/20188/13/20188/13/2018 9:52:12 AMAFAIL
garage code 2468 Phone #: ###-#### Inspection requested via web by Darryn Coburn...

no access...no garage door opener
ELE18-02160 Electrical Rough-In8/10/20188/13/20188/13/2018 9:41:25 AMAPASS
Winfred Phone #: ###-####...rough ok to cover
ELE18-02916 Electrical Rough-In8/10/20188/13/20188/13/2018 9:15:38 AMANR
Please call Wayne, ###-####, with any questions Phone #: ###-#### Inspection requested via web by William Salts...not ready
ELE18-03050 Conference8/10/20188/13/20188/13/2018 8:59:20 AMAPASS
John Phone #: ###-####...
pamphlet given...homeowner competent...requirements for bath remodel discussed...using existing circuits
ELE18-02989 Temporary Service8/10/20188/13/20188/13/2018 8:21:19 AMAPASS
Phone #: ###-#### Inspection requested via web by Darryn Coburn...
t/s u/g new ok