ELE06-02774
| Final | 8/11/2006 | 8/14/2006 | 8/14/2006 4:45:54 PM | P | PASS |
|
|
Ready for final, please call Dan, thank you; Phone #: ###-#### Internet Inspection Request from: Wendy Waters ok to final
|
ELE06-00091
| Final | 8/13/2006 | 8/14/2006 | 8/14/2006 4:24:22 PM | P | FAIL |
|
|
Phone #: ###-#### Internet Inspection Request from: steve creswell called, left message, left corr notice, nec 210.8(A)(C) island recpt shall be gfci protected,422.31(B) dishwasher shll have lockout, 410.6 luminaire shall be installed in dining room closet, 406.4(D) recpt face shall be flush with or project from faceplate, 406.5 recpt faceplates shall seat against finished surface, and be supplied at water softener and hw heater area, BCC dome over stairs shall be covered or finished, outside rear recpt shall operate correctly
|
ELE06-02057
| ELE-Aging Inspection | 8/14/2006 | 8/14/2006 | 8/14/2006 3:59:54 PM | | NR |
|
|
called, suc
|
ELE06-00921
| ELE-Aging Inspection | 8/14/2006 | 8/14/2006 | 8/14/2006 3:19:12 PM | | DONE |
|
|
called, working on getting field evauation for generator, Generator apparently not connected per elect.
|
ELE06-01882
| Final | 8/14/2006 | 8/14/2006 | 8/14/2006 3:03:43 PM | P | PASS |
|
|
Work performed by Greg Fanrworth.; Phone #: ###-#### Internet Inspection Request from: Matt Santacruz ok to final
|
ELE06-02926
| Final | 8/14/2006 | 8/14/2006 | 8/14/2006 1:32:07 PM | P | PASS |
|
|
need inspection @ space #5 to get power turned back on.; Phone #: ###-#### Internet Inspection Request from: BRIAN KEITH see p/s ok to final
|
ELE06-02926
| Permanent Service | 8/14/2006 | 8/14/2006 | 8/14/2006 1:31:38 PM | P | PASS |
|
|
need inspection @ space #5 to get power turned back on.; Phone #: ###-#### Internet Inspection Request from: BRIAN KEITH corr made, p/s o/h rec ok
|
ELE06-02926
| Final | 8/14/2006 | 8/14/2006 | 8/14/2006 1:29:45 PM | P | PASS |
|
|
need inspection @ space #5 to get power turned back on.; Phone #: ###-#### Internet Inspection Request from: BRIAN KEITH corr made, p/s o/h rec ok
|
ELE06-02968
| Permanent Service | 8/14/2006 | 8/14/2006 | 8/14/2006 12:40:01 PM | P | PASS |
|
|
brad; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles called contr to provide abrasion protection for gec, p/s u/g rec ok
|
ELE06-02823
| Final | 8/11/2006 | 8/14/2006 | 8/14/2006 11:54:09 AM | A | PASS |
|
|
Internet Inspection Request from: Tyler Bowen corr made, ok to final
|
ELE06-02980
| Rough-In Permanent Service | 8/11/2006 | 8/14/2006 | 8/14/2006 9:25:26 AM | A | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Alan Lusk called contr to chg recpt location up bedroom, add recpt in kitchen, finish make-up, change room count to 20 rooms, ok to pour gec, told to call for inspection before backfill gec, ric ok, p/s u/g n ok
|
ELE06-02967
| Rough-In Permanent Service | 8/10/2006 | 8/14/2006 | 8/14/2006 9:21:34 AM | A | PASS |
|
|
adam; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles called contr, left survey, BCC all make-up shall be done-front and rear lights and recpts plus 2 boxes in kitchen, box for hw heater, ric ok, p/s o/h n ok
|