Inspections for the day of: Tuesday, August 14, 2007.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE05-03636 ELE-Aging Inspection8/14/20078/14/20078/21/2007 10:17:36 AM DONE
called for contr to perform corrections and call for inspection
ELE06-03549 Conference8/14/20078/14/20078/14/2007 4:24:11 PMPDONE
Scheduled by a contractor via Hello! on 8/14/2007 at 8:24:35 AM. Contact: ###-####. looked at plans and beginning of ri, old panel and talked about new subpanel, talked about make-up, stapling, wiring devices, access holes, partial power with new subpanel and not changing service or new addition not being complete
ELE07-02688 Electrical Rough-In8/14/20078/14/20078/14/2007 3:50:10 PMPPASS
Underground Inspection. Please call Brian T. when complete ###-####. Phone #: ###-#### Internet Inspection Request from: todd hall u/g ok to cover
ELE07-02351 Final8/14/20078/14/20078/14/2007 3:19:40 PMPFAIL
Cell: ###-####; Carol; Phone #: ###-#### Internet Inspection Request from: Hattie James called, left corr notice, nec 406.8(B) recpts in wet location shall have enclosure that is weatherproof whether or not plug inserted, 210.8(A)(2) gfci shall be provided for all recpts in garage or accessory bldg
ELE07-02793 Rough-In Permanent Service8/9/20078/14/20078/14/2007 2:19:13 PMPPASS
mitch Phone #: ###-#### Note: call 1/2 hr prior to inspection ric ok, p/s o/h rec ok
ELE07-01657 Rough-In Permanent Service8/14/20078/14/20078/14/2007 1:54:12 PMPFAIL
Chris; Phone #: ###-#### Internet Inspection Request from: Hattie James called, left corr notice, nec 314.20 in walls of combustible material, boxes shall be flush with or project from finished surface, 110.26(F)(1)(a) there shall be no foreign ducts in dedicated panel space, 300.4(A)&(D) edge of bored holes and nm cable shall be 1 1/4" from edge of framing members, 334.24 bend radius of nm cable shall be 5 times diameter of cable, 250.80 house panel enclosure shall be grounded, BCC address shall be posted
ELE07-01344 Final8/14/20078/14/20078/14/2007 1:04:23 PMPPASS
Thank you!! Phone #: ###-#### Internet Inspection Request from: Tracy Robertson ok to final, signed occ card
ELE07-02219 Final8/14/20078/14/20078/14/2007 11:17:03 AMPPASS
Francis; re-inspection; call for access; Phone #: ###-#### Internet Inspection Request from: Hattie James corr made, ok to final
ELE07-02814 Electrical Rough-In8/13/20078/14/20078/14/2007 10:36:11 AMAPART
call Loren for inspection of all outside and inside underground as well as east side office walls. please try to make inspection time around 10am if possible.thanks guys Phone #: ###-#### Internet Inspection Request from: Loren Ramsey walls east side and north wall east side only ok to cover. u/g will call for pm
ELE06-03918 Final8/13/20078/14/20078/14/2007 9:59:20 AMAPASS
josh Phone #: ###-#### ok to final bedroom, will pull new permit for garage
ELE07-02442 Final8/13/20078/14/20078/14/2007 9:16:22 AMAPASS
Contact: James Phone #: ###-#### Internet Inspection Request from: HARVEY REYNA ok to final
ELE07-02821 Electrical Rough-In8/13/20078/14/20078/14/2007 8:49:55 AMAPASS
tim Phone #: ###-#### ric kitchen, dining area ok
ELE07-01344 Final8/14/20078/14/20078/14/2007 8:48:43 AMPCANC
Thank You!! Phone #: ###-#### Internet Inspection Request from: Tracy Robertson Inspection cancelled from web by: Tracy Robertson
ELE07-02285 Final8/14/20078/14/20078/14/2007 12:00:00 AMPCANC
Phone #: ###-#### Internet Inspection Request from: Steve Craig; contractor called to cancel inspection
ELE07-02219 Final8/13/20078/14/20078/13/2007 4:32:12 PMAFAIL
Francis, please call 1st for access; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt called, left message, a/c nameplate with elec data not found, told contr that it shall be in place for inspection to pass so o/c protection can be verified per nec 440.4