Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC07-00125 Random Inspection8/14/20078/14/20078/14/2007 3:26:07 PMPFAIL
Correction to RP; Signage, maintance of drop inlets needed, hard surfaces need sweeping, top dressing on constructio entrance/s. Will re-inspect.
ESC07-00340 Site Preparation8/14/20078/14/20078/14/2007 2:45:51 PMPPART
Things look rather good; minor mortar from block wall on hardsurfaces, 5 gallon buckets need to be containerized. Drop inlets are protected. Informed RP
ESC05-00072 Random Inspection8/14/20078/14/20078/14/2007 11:41:17 AMAFAIL
No signage, needs sweeping on sidewalk and curb, trash maintance etc.
ESC06-00686 Random Inspection8/14/20078/14/20078/14/2007 11:39:16 AMAFAIL
Needs drop inlet protection, access controls, and site stablized.