Inspections for the day of: Wednesday, August 14, 2013.
Number of inspections: 18
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC12-00967 Aging Inspection8/14/20138/14/20138/15/2013 2:07:04 PM PASS
Job looks finished
ELE13-02186 Final8/14/20138/14/20138/14/2013 5:11:50 PMPCANC
wire gas furnace Phone #: ###-#### >> Inspection requested via web by PAT MILLER
See ri
ELE13-02186 Electrical Rough-In8/14/20138/14/20138/14/2013 5:11:03 PMPCANC
wire gas furnace Phone #: ###-#### >> Inspection requested via web by PAT MILLER
unable to make it during work day. Contractor to reschedule
GCE13-00136 GCE-Rough-In8/14/20138/14/20138/14/2013 4:59:21 PMPPASS
###-#### Room on back of house rough in ok cover
ELE13-01759 Final8/14/20138/14/20138/14/2013 4:18:00 PMPPASS
Gfci has been repaired Phone #: ###-#### >> Inspection requested via web by Steve Craig Final ok
ESC13-00811 Site Preparation8/13/20138/14/20138/14/2013 4:09:37 PMAPASS
eric Phone #: ###-#### Verbal to post sign. Did not enter rear of house do to demo work
ELE13-02170 Electrical Rough-In8/14/20138/14/20138/14/2013 3:59:35 PMPPASS
Someone will be there. Thanks Phone #: ###-#### >> Inspection requested via web by Clay Morgan Bath remodel rough in ok cover
ELE13-01026 Final8/14/20138/14/20138/14/2013 3:53:41 PMPFAIL
Phone #: ###-#### >> Inspection requested via web by Craig Korell
210.52 (C)(1)- A receptical outlet shall be installed at each wall counter top space 12" or wider.
210.63- A 125 volt single phase 15 or 20 amp receptical outlet shall be installed at same level, accessible and within 25' of AC unit.
ELE13-02184 Electrical Rough-In8/14/20138/14/20138/14/2013 3:22:23 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Eddy Udry Master bed and bath remodel rough in ok cover
ELE13-02191 Permanent Service8/14/20138/14/20138/14/2013 3:03:50 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Bryan McLaughlin
p/s o/h n ok
ELE13-02187 Electrical Rough-In8/14/20138/14/20138/14/2013 2:14:46 PMPPASS
front porch Phone #: ###-#### >> Inspection requested via web by PAT MILLER
Rough in ok cover
ELE13-01745 Electrical Rough-In8/14/20138/14/20138/14/2013 2:01:05 PMPPASS
Contact: Wes Powell Phone #: ###-#### >> Inspection requested via web by Deb Gooden 6th floor walls all ok except 642, 643, 650.
ELE13-02160 Temporary Service8/13/20138/14/20138/14/2013 9:15:54 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Alan Lusk t/s u/g n ok
ELE13-02157 Temporary Service8/13/20138/14/20138/14/2013 9:09:23 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Alan Lusk t/s u/g n ok
ELE13-02159 Rough-In Permanent Service8/13/20138/14/20138/14/2013 9:01:08 AMACANC
Phone #: ###-#### >> Inspection requested via web by Alan Lusk Needed temp service
ELE13-02159 Temporary Service8/14/20138/14/20138/14/2013 9:00:50 AMPPASS
Phone #: ###-#### >> Inspection requested via web by Alan Lusk t/s u/g n ok
ELE13-01759 Final8/14/20138/14/20138/14/2013 8:36:41 AMAFAIL
Back door to garage will be unlocked. Phone #: ###-#### >> Inspection requested via web by Steve Craig Front outdoor receptical GFCI will not trip when tested
ELE13-02172 Temporary Service8/13/20138/14/20138/14/2013 8:22:03 AMAPASS
temp pole Phone #: ###-#### >> Inspection requested via web by TOM BICANDI
t/s u/g n ok