ELE17-01337
| Electrical Rough-In | 8/10/2017 | 8/14/2017 | 8/14/2017 3:23:11 PM | P | PASS |
|
|
we are requesting an underground inspection for the pool bonding for Monday Aug. 14th in the afternoon. Our contact is Rick @ ###-####. Thank you. Phone #: ###-#### Inspection requested via web by Clint Tate Discussed the use of AFC multi 12 conductor cables and if derating as per 310.15(B)(3) apply. Listing confirmed and derating does apply as per manufacturers instructions. Underground for south footings and perimeter bond for pool, ladders, and chair rough in ok cover.
|
ELE17-00733
| Final | 8/14/2017 | 8/14/2017 | 8/14/2017 2:47:36 PM | P | PASS |
|
|
For access please call Ed 1/2 hr prior to inspection. ###-#### Phone #: ###-#### Inspection requested via web by Terry Scott Final ok
|
ELE17-02324
| Electrical Rough-In | 8/14/2017 | 8/14/2017 | 8/14/2017 1:43:13 PM | P | FAIL |
|
|
Rough in Inspection Phone #: ###-#### Inspection requested via web by Douglas Hackney 300.4- MN cable shall be protected from damage where run thru bored holes that dor not maintain 1 1/4" from framing surface. 2 up lower plates under switch at top of stair and under bed window. 334.30 NM cable shall be secured within 12" of hall sconce. 422.11- 20 amp 120 volt circuit spec for furnace 15 amp installed. Soffits ok
|
ELE17-01720
| Final | 8/11/2017 | 8/14/2017 | 8/14/2017 12:36:02 PM | A | PASS |
|
|
The key is on the meterbase panel, any issues plz let me know, thx, TW Phone #: ###-#### Inspection requested via web by Stephen Kren Final ok
|
ELE17-02356
| Electrical Rough-In | 8/11/2017 | 8/14/2017 | 8/14/2017 11:08:26 AM | P | CANC |
|
|
Underground and bonding inspection Phone #: ###-#### >> Inspection requested via web by Louis Keller Inspection cancelled from web by: Louis Keller
|
ELE17-02629
| Electrical Rough-In | 8/13/2017 | 8/14/2017 | 8/14/2017 9:53:32 AM | A | PASS |
|
|
Please inspect the South West most room in the back of the house and approve for cover so that sheetrock and then framing for that closet can be added inside that room. The room was an office before with above counter outlets and is being converted to a bedroom. (We will have future rough-in inspections in the kitchen and other areas of the house at a later date.) Phone #: ###-#### Inspection requested via web by nathan palmer Drying out house from flood. Kitchen cabinet layout may change in future. No new walls as of this inspection. Lowered receptacle locations in room noted rough in ok cover
|
ELE17-01436
| Final | 8/11/2017 | 8/14/2017 | 8/14/2017 9:16:25 AM | A | PASS |
|
|
CODE 1234 Phone #: ###-#### Inspection requested via web by Bob Glenn temp pole final ok
|
ELE17-02073
| Final | 8/14/2017 | 8/14/2017 | 8/14/2017 9:16:08 AM | P | PASS |
|
|
Final ok
|