Inspections for the day of: Monday, August 14, 2017.
Number of inspections: 8
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE17-01337 Electrical Rough-In8/10/20178/14/20178/14/2017 3:23:11 PMPPASS
we are requesting an underground inspection for the pool bonding for Monday Aug. 14th in the afternoon. Our contact is Rick @ ###-####. Thank you. Phone #: ###-#### Inspection requested via web by Clint Tate
Discussed the use of AFC multi 12 conductor cables and if derating as per 310.15(B)(3) apply. Listing confirmed and derating does apply as per manufacturers instructions.
Underground for south footings and perimeter bond for pool, ladders, and chair rough in ok cover.
ELE17-00733 Final8/14/20178/14/20178/14/2017 2:47:36 PMPPASS
For access please call Ed 1/2 hr prior to inspection. ###-#### Phone #: ###-#### Inspection requested via web by Terry Scott Final ok
ELE17-02324 Electrical Rough-In8/14/20178/14/20178/14/2017 1:43:13 PMPFAIL
Rough in Inspection Phone #: ###-#### Inspection requested via web by Douglas Hackney
300.4- MN cable shall be protected from damage where run thru bored holes that dor not maintain 1 1/4" from framing surface. 2 up lower plates under switch at top of stair and under bed window.
334.30 NM cable shall be secured within 12" of hall sconce.
422.11- 20 amp 120 volt circuit spec for furnace 15 amp installed.
Soffits ok
ELE17-01720 Final8/11/20178/14/20178/14/2017 12:36:02 PMAPASS
The key is on the meterbase panel, any issues plz let me know, thx, TW Phone #: ###-#### Inspection requested via web by Stephen Kren
Final ok
ELE17-02356 Electrical Rough-In8/11/20178/14/20178/14/2017 11:08:26 AMPCANC
Underground and bonding inspection Phone #: ###-#### >> Inspection requested via web by Louis Keller Inspection cancelled from web by: Louis Keller
ELE17-02629 Electrical Rough-In8/13/20178/14/20178/14/2017 9:53:32 AMAPASS
Please inspect the South West most room in the back of the house and approve for cover so that sheetrock and then framing for that closet can be added inside that room. The room was an office before with above counter outlets and is being converted to a bedroom. (We will have future rough-in inspections in the kitchen and other areas of the house at a later date.) Phone #: ###-#### Inspection requested via web by nathan palmer
Drying out house from flood. Kitchen cabinet layout may change in future. No new walls as of this inspection. Lowered receptacle locations in room noted rough in ok cover
ELE17-01436 Final8/11/20178/14/20178/14/2017 9:16:25 AMAPASS
CODE 1234 Phone #: ###-#### Inspection requested via web by Bob Glenn
temp pole final ok
ELE17-02073 Final8/14/20178/14/20178/14/2017 9:16:08 AMPPASS
Final ok