Inspections for the day of: Tuesday, August 14, 2018.
Number of inspections: 10
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorTom Saunders
TitleELE-INSPECTOR
Phone #208-794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE18-02226 Permanent Service8/13/20188/14/20188/14/2018 2:59:08 PMPPASS
New Service line installed by Idaho Power. New Meter Box/Panel Combo, replacing the Current panel with a sub panel. Install happening in the AM. Not sure when exactly it''ll be finished and ready for inspection, but would like power restored and not be without power that evening/night. Phone #: ###-#### Inspection requested via web by Kevin Hanners...
verify at final sub panel labelling and reducing washers on chase nipple...

p/s u/g reconnect ok
ELE18-01463 Final8/14/20188/14/20188/14/2018 2:33:42 PMPFAIL
Call Tara Young for access
###-#### Phone #: ###-#### Inspection requested via web by jamie berg...too much to list...verify on correction notice at job site
ELE18-02155 Final8/14/20188/14/20188/14/2018 1:33:15 PMPPASS
Please call when done ###-#### Phone #: ###-#### Inspection requested via web by Thomas wilson...ok to final
ELE18-03030 Rough-In Permanent Service8/14/20188/14/20188/14/2018 1:11:23 PMPFAIL
Phone #: ###-#### Inspection requested via web by Barbara Szurgot...

1..service shall have supplemental ground rod 6ft apart...250.53...meet 2008 NEC code


2..breaker supplying future sub panel too large for busing in new meter base/panel..manufacturers rating...70A max..110.3


3.. NMC shall not be stapled on edge...multiple locations..334.30
4..intersystem bond bar shall be installed by final
ELE18-00183 Final8/14/20188/14/20188/14/2018 12:28:36 PMPPASS
call for access if needed- Ron Phone #: ###-####...corrections made ok to final
ELE18-02563 Electrical Rough-In8/13/20188/14/20188/14/2018 12:07:50 PMPPART
Patio/fireplace Phone #: ###-#### Inspection requested via web by Kevin Burke...patio ok to cover...no fireplace installed
ELE18-01894 Final8/13/20188/14/20188/14/2018 10:26:42 AMAPASS
Phone #: ###-#### Inspection requested via web by Darryn Coburn...ok to final
ELE18-02132 Final8/13/20188/14/20188/14/2018 9:39:00 AMAPASS
Lock box on ac code is 2187 Phone #: ###-#### Inspection requested via web by danny perrine...ok to final
ELE18-02979 Electrical Rough-In8/13/20188/14/20188/14/2018 8:33:11 AMAPASS
Jason Curley, crew lead: ###-####. Install is taking place on 8/14 at 7 am. Phone #: ###-#### Inspection requested via web by BRS Permitting....UL listed equipment verified...40A breaker in panel with label applied
ELE12-01653 DOC - Permit Expired8/14/20188/14/20188/14/2018 8:08:44 AMAPASS
permit expired...multiple attempts made