ELE18-02226
| Permanent Service | 8/13/2018 | 8/14/2018 | 8/14/2018 2:59:08 PM | P | PASS |
|
|
New Service line installed by Idaho Power. New Meter Box/Panel Combo, replacing the Current panel with a sub panel. Install happening in the AM. Not sure when exactly it''ll be finished and ready for inspection, but would like power restored and not be without power that evening/night. Phone #: ###-#### Inspection requested via web by Kevin Hanners... verify at final sub panel labelling and reducing washers on chase nipple...
p/s u/g reconnect ok
|
ELE18-01463
| Final | 8/14/2018 | 8/14/2018 | 8/14/2018 2:33:42 PM | P | FAIL |
|
|
Call Tara Young for access ###-#### Phone #: ###-#### Inspection requested via web by jamie berg...too much to list...verify on correction notice at job site
|
ELE18-02155
| Final | 8/14/2018 | 8/14/2018 | 8/14/2018 1:33:15 PM | P | PASS |
|
|
Please call when done ###-#### Phone #: ###-#### Inspection requested via web by Thomas wilson...ok to final
|
ELE18-03030
| Rough-In Permanent Service | 8/14/2018 | 8/14/2018 | 8/14/2018 1:11:23 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Barbara Szurgot...
1..service shall have supplemental ground rod 6ft apart...250.53...meet 2008 NEC code
2..breaker supplying future sub panel too large for busing in new meter base/panel..manufacturers rating...70A max..110.3
3.. NMC shall not be stapled on edge...multiple locations..334.30 4..intersystem bond bar shall be installed by final
|
ELE18-00183
| Final | 8/14/2018 | 8/14/2018 | 8/14/2018 12:28:36 PM | P | PASS |
|
|
call for access if needed- Ron Phone #: ###-####...corrections made ok to final
|
ELE18-02563
| Electrical Rough-In | 8/13/2018 | 8/14/2018 | 8/14/2018 12:07:50 PM | P | PART |
|
|
Patio/fireplace Phone #: ###-#### Inspection requested via web by Kevin Burke...patio ok to cover...no fireplace installed
|
ELE18-01894
| Final | 8/13/2018 | 8/14/2018 | 8/14/2018 10:26:42 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Darryn Coburn...ok to final
|
ELE18-02132
| Final | 8/13/2018 | 8/14/2018 | 8/14/2018 9:39:00 AM | A | PASS |
|
|
Lock box on ac code is 2187 Phone #: ###-#### Inspection requested via web by danny perrine...ok to final
|
ELE18-02979
| Electrical Rough-In | 8/13/2018 | 8/14/2018 | 8/14/2018 8:33:11 AM | A | PASS |
|
|
Jason Curley, crew lead: ###-####. Install is taking place on 8/14 at 7 am. Phone #: ###-#### Inspection requested via web by BRS Permitting....UL listed equipment verified...40A breaker in panel with label applied
|
ELE12-01653
| DOC - Permit Expired | 8/14/2018 | 8/14/2018 | 8/14/2018 8:08:44 AM | A | PASS |
|
|
permit expired...multiple attempts made
|