ELE06-01340
| Final | 8/15/2006 | 8/15/2006 | 8/15/2006 3:44:54 PM | P | PASS |
|
|
justin; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley
|
ELE06-03008
| Electrical Rough-In | 8/14/2006 | 8/15/2006 | 8/15/2006 3:04:46 PM | P | FAIL |
|
|
dan ###-#### corr. fee due called 314.16 box fill master bath, 250.122 use #12 for 20 amp equip grd pigtails, 300.4 nail plates and 11/4", 210.52(A) outlet spacing N W corner exercise rm, 314.17 (A&C) replace 2 gang boxes with broken clamps, 334,23 protect cables within 6 ft of attic access, note complete all wiring install all recess fixtures, update permit from 2rms to 11rms
|
ELE06-02605
| Electrical Rough-In | 8/15/2006 | 8/15/2006 | 8/15/2006 2:20:25 PM | P | PART |
|
|
butch - underground homeside concession stand area (30' ditch); Phone #: ###-#### Internet Inspection Request from: Barbara Buckley ok west side
|
ELE06-01487
| Final | 8/15/2006 | 8/15/2006 | 8/15/2006 1:44:42 PM | P | PASS |
|
|
garage access 781 enter Internet Inspection Request from: Melyne Davis
|
ELE06-01338
| Final | 8/15/2006 | 8/15/2006 | 8/15/2006 1:44:26 PM | P | PASS |
|
|
garage access code 791 enter Internet Inspection Request from: Melyne Davis
|
ELE06-00571
| Final | 8/15/2006 | 8/15/2006 | 8/15/2006 1:16:22 PM | P | PASS |
|
|
Internet Inspection Request from: Melyne Davis ok
|
ELE06-00634
| Final | 8/11/2006 | 8/15/2006 | 8/15/2006 12:43:06 PM | A | FAIL |
|
|
TOM; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles called no response never had r/i for walls, only ceiling
|
ELE05-02003
| Electrical Rough-In | 8/14/2006 | 8/15/2006 | 8/15/2006 11:46:42 AM | A | PART |
|
|
jerod Note; exercise room 1st floor; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ok anop
|
ELE05-03660
| Final | 8/14/2006 | 8/15/2006 | 8/15/2006 10:26:29 AM | A | NR |
|
|
need a final on what is completed so they can get occupancy, Call Anita ###-#### to get access to building. Any questions call George @ ###-#### Internet Inspection Request from: Andy Rose called install outlet west end parking lot, needs conn for mc range hoods, bond hot and cold, box extensions, paneling, no splices allowed in zip cord chain suppended fixtures
|
ELE06-02975
| Electrical Rough-In | 8/14/2006 | 8/15/2006 | 8/15/2006 9:28:37 AM | A | PART |
|
|
Inspection for ceiling in main walk thru area so owner can install insulation and drywall.; Phone #: ###-#### Internet Inspection Request from: todd hall ok
|
ELE06-03010
| Final | 8/14/2006 | 8/15/2006 | 8/15/2006 8:49:04 AM | A | NH |
|
|
david ###-#### called no access
|
ELE06-01470
| Electrical Rough-In | 8/14/2006 | 8/15/2006 | 8/15/2006 8:15:12 AM | A | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Barbara Stitt ok
|