Inspections for the day of: Tuesday, August 15, 2006.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE06-01808 Final8/15/20068/15/20068/15/2006 4:37:59 PMPPASS
mike; Phone #: ###-#### Note: please call access Internet Inspection Request from: Cathy Chiles ok to final
ELE06-01980 Final8/15/20068/15/20068/15/2006 4:01:25 PMPFAIL
Phone #: ###-#### Internet Inspection Request from: DJ Carman called, left corr notice, nec 314.23(B) box shall be rigidly supported by structural member, 358.30(A) emt shall be supported within 3' of box and or termination, 348.30(A) fmc shall be supported within 12" of box, 110.3(A) transformer shall be listed as an approved j-box or pull-box,110.3(B) equipment shall be installed per instructions in listing, BCC listing shall be provided for compressor, wiring shall be per mfgrs instructions
ELE06-03024 Permanent Service8/15/20068/15/20068/15/2006 3:12:25 PMPPASS
john - call prior for access info - pole(in yard of #4) and meter base at #5; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley p/s o/h n ok
ELE06-02799 Permanent Service8/15/20068/15/20068/15/2006 2:09:10 PMPPASS
daryl; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley p/s o/h rec ok
ELE06-03015 Permanent Service8/15/20068/15/20068/15/2006 1:52:25 PMPFAIL
need perm service inspection on new 200 amp panel. thank you.; Phone #: ###-#### Internet Inspection Request from: BRIAN KEITH met contr, need to see gnd rods, left corr notice, nec 230.24(A)service drop conductors shall have a vertical clearance of not less than 8' above the roof surface, will recall for final, rest ok
ELE06-03016 Electrical Rough-In8/15/20068/15/20068/15/2006 1:21:09 PMPPASS
ed - call 1/2 hr prior for access; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley met contr, told to mount rear light boxes and provide abrasion protection and termination points for low voltage, mentioned need afci at final for bedroom in basement , will have auto blind closer for skylight, ric ok
ELE06-02008 Electrical Rough-In8/15/20068/15/20068/15/2006 12:49:41 PMPNR
Scheduled by a contractor via Hello! on 8/15/2006 at 7:33:35 AM. Contact: ###-####. called contr, nr w/1 1/2", fee due, needs to recall
ELE06-01733 Final8/14/20068/15/20068/15/2006 11:51:39 AMAPASS
RICH; Phone #: ###-#### nOTE: PLEASE FOR CODE Internet Inspection Request from: Cathy Chiles ok to final
ELE06-03006 Rough-In Permanent Service8/14/20068/15/20068/15/2006 10:20:23 AMAPASS
degrange; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ric ok, p/s u/g n ok
ELE06-01310 Final8/14/20068/15/20068/15/2006 9:59:02 AMAPASS
Phone #: ###-#### Internet Inspection Request from: Cathy Chiles corr made, ok to final
ELE06-01612 Permanent Service8/15/20068/15/20068/15/2006 9:32:30 AMAPASS
Phone #: ###-#### Internet Inspection Request from: Jim Williams p/s u/g n ok, house panel only
ELE06-02613 Electrical Rough-In8/14/20068/15/20068/15/2006 8:43:38 AMAPART
THIS IS FOR A CEILING INSPECTION, ANY QUESTIONS PLEASE CALL JAMES LINGELBAUGH; Phone #: ###-#### Internet Inspection Request from: Jeff Radford east 1/2 ceiling 2nd floor ok to cover
ELE06-00113 Electrical Rough-In8/14/20068/15/20068/15/2006 8:39:50 AMAPART
CONTACT: GREG PACK - CEILING INSPECTION 8TH FLOOR; Phone #: ###-#### Internet Inspection Request from: Deb McCoy ceilings and walls anop ok to cover