ELE07-01788
| ELE-Aging Inspection | 8/15/2007 | 8/15/2007 | 8/21/2007 9:58:15 AM | | DONE |
|
|
|
ELE07-02295
| Final | 8/15/2007 | 8/15/2007 | 8/15/2007 3:08:43 PM | P | PASS |
|
|
Lloyd; Phone #: ###-#### Internet Inspection Request from: Hattie James ok no card
|
ELE07-02840
| Permanent Service | 8/14/2007 | 8/15/2007 | 8/15/2007 2:42:10 PM | P | PASS |
|
|
Taking out old service replacing with new Phone #: ###-#### Internet Inspection Request from: Curtis Dunham needs to grd u/g water pipe 1st 5ft, remove phone/catv from service mast, needs guy kit to terminate above rigid coupling, contr will call for final when ready p/s o/h rec. ok
|
ELE07-02830
| Permanent Service | 8/15/2007 | 8/15/2007 | 8/15/2007 2:03:58 PM | P | PASS |
|
|
###-#### p/s o/h rec. ok
|
ELE07-02830
| Final | 8/15/2007 | 8/15/2007 | 8/15/2007 2:03:32 PM | P | PASS |
|
|
###-#### ok
|
ELE07-02535
| Electrical Rough-In | 8/15/2007 | 8/15/2007 | 8/15/2007 1:31:22 PM | P | FAIL |
|
|
steve Phone #: ###-#### Note: after 2:00 pm please corr. do not cover posted called, 300.4 nail plates and 11/4" for cables parallel, note inside and outside edges for holes and cables parallel, 314.20 outside boxes shall be flush with finish siding, 300.14 free length grd wires cut short, if inside not finished protect cables run horizontally 334.15, told owner requirements at time of conference, and do not give me neighbor's phone number to discuss code questions I only deal with homeowner
|
ELE07-02848
| Electrical Rough-In | 8/15/2007 | 8/15/2007 | 8/15/2007 12:46:47 PM | P | PASS |
|
|
patio addition in back homeowner handicapped Phone #: ###-#### Internet Inspection Request from: joe wheeler r/i ok
|
ELE07-02757
| Electrical Rough-In | 8/15/2007 | 8/15/2007 | 8/15/2007 12:19:41 PM | P | PASS |
|
|
BILL Phone #: ###-#### Internet Inspection Request from: Bob Glenn ok needs insulated egquip grd from switch to spa
|
ELE07-02757
| Final | 8/15/2007 | 8/15/2007 | 8/15/2007 12:18:53 PM | P | PASS |
|
|
BILL Phone #: ###-#### Internet Inspection Request from: Bob Glenn
|
ELE07-02285
| Final | 8/14/2007 | 8/15/2007 | 8/15/2007 11:02:36 AM | A | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Steve Craig called needs to bond H&C at WH ok card signed
|
ELE07-01691
| Electrical Rough-In | 8/14/2007 | 8/15/2007 | 8/15/2007 10:34:55 AM | A | PART |
|
|
Scheduled by a contractor via Hello! on 8/14/2007 at 7:45:37 AM. Contact: ###-####. ceilings anop
|
ELE07-02830
| Rough-In Permanent Service | 8/14/2007 | 8/15/2007 | 8/15/2007 10:03:49 AM | A | NR |
|
|
Pat; Phone #: ###-#### Internet Inspection Request from: Hattie James; call for access see added pm rquest
|
ELE07-02757
| Final | 8/15/2007 | 8/15/2007 | 8/15/2007 9:19:54 AM | P | CANC |
|
|
BILL Phone #: ###-#### Internet Inspection Request from: Bob Glenn Inspection cancelled from web by: Bob Glenn
|
ELE07-02838
| Electrical Rough-In | 8/14/2007 | 8/15/2007 | 8/15/2007 9:16:09 AM | A | PART |
|
|
Chris; Phone #: ###-#### Internet Inspection Request from: Hattie James walls ok
|
ELE07-01614
| Final | 8/14/2007 | 8/15/2007 | 8/15/2007 8:43:29 AM | A | PASS |
|
|
Thank you!! Phone #: ###-#### Internet Inspection Request from: Tracy Robertson ok card signed
|