ELE06-04441
| ELE-Aging Inspection | 8/15/2008 | 8/15/2008 | 8/15/2008 4:05:17 PM | | FAIL |
|
|
work stopped
|
ELE06-04441
| DOC - Permit Expired | 8/15/2008 | 8/15/2008 | 8/15/2008 4:05:04 PM | P | PASS |
|
|
work stopped
|
ELE06-04440
| DOC - Permit Expired | 8/15/2008 | 8/15/2008 | 8/15/2008 4:04:30 PM | P | PASS |
|
|
work stopped
|
ELE08-01218
| DOC - Permit Finaled | 8/15/2008 | 8/15/2008 | 8/15/2008 3:53:22 PM | P | PASS |
|
|
|
ELE08-02021
| Electrical Rough-In | 8/13/2008 | 8/15/2008 | 8/15/2008 3:32:44 PM | P | PART |
|
|
Contact is George Morris ###-####, rough in. Phone #: ###-#### Internet Inspection Request from: Debby Ellis phase 1 wall R/I Ok
|
ESC08-00455
| General Inspection | 8/15/2008 | 8/15/2008 | 8/15/2008 3:32:07 PM | P | PASS |
|
|
looks ok
|
ELE08-02303
| Conference | 8/15/2008 | 8/15/2008 | 8/15/2008 2:53:10 PM | P | PART |
|
|
electrician is Kyle Sharp, Phone #: ###-#### Internet Inspection Request from: Jarrod Clymer support mc cable above ceiling and 250.148
|
ELE08-01683
| Electrical Rough-In | 8/14/2008 | 8/15/2008 | 8/15/2008 2:26:09 PM | P | PART |
|
|
Contact: Chris Carmine - Underground inspection please Phone #: ###-#### Internet Inspection Request from: Deb Gooden north west corner underground ok no esc in project
|
ELE08-02291
| Conference | 8/15/2008 | 8/15/2008 | 8/15/2008 1:38:33 PM | P | PASS |
|
|
Kevin Phone #: ###-#### underground ok to cover
|
ESC08-00568
| General Inspection | 8/15/2008 | 8/15/2008 | 8/15/2008 1:38:05 PM | P | PASS |
|
|
esc looked ok
|
ELE08-01509
| Electrical Rough-In | 8/14/2008 | 8/15/2008 | 8/15/2008 11:35:14 AM | A | PART |
|
|
Bathrooms on third floor ready for cover Phone #: ###-#### Internet Inspection Request from: Lloyd Looney R/I Ok no esc in project
|
ESC08-00602
| General Inspection | 8/15/2008 | 8/15/2008 | 8/15/2008 10:53:50 AM | A | PASS |
|
|
looks ok
|
ELE08-02301
| Electrical Rough-In | 8/14/2008 | 8/15/2008 | 8/15/2008 10:53:16 AM | A | PASS |
|
|
George Phone #: ###-####
|
ELE08-02296
| Electrical Rough-In | 8/15/2008 | 8/15/2008 | 8/15/2008 10:38:14 AM | P | PASS |
|
|
eric Phone #: ###-#### underground ok no esc in project
|
ELE08-02296
| Final | 8/14/2008 | 8/15/2008 | 8/15/2008 10:35:46 AM | A | NR |
|
|
eric Phone #: ###-#### R/I Only
|
ELE08-01808
| Electrical Rough-In | 8/15/2008 | 8/15/2008 | 8/15/2008 9:53:11 AM | A | PASS |
|
|
Ceiling Inspection Phone #: ###-#### Internet Inspection Request from: Brandon Blackham ceiling ok called brandon and told him that the wall bracing has pushed 2 of his cables on to the grid since it has to be fixed to get tile in and everything else was ok i passed it.
|
ELE08-02298
| Electrical Rough-In | 8/14/2008 | 8/15/2008 | 8/15/2008 9:26:08 AM | A | PASS |
|
|
Mike- call for access Phone #: ###-#### R/I Ok No esc on project
|
ELE08-01313
| Final | 8/14/2008 | 8/15/2008 | 8/15/2008 8:43:08 AM | A | PASS |
|
|
code to enter 1234 call Steve 1/2 hr. before for access ###-#### Phone #: ###-#### Internet Inspection Request from: Rick Beckman plans that I was shown matched job.
|