ELE13-02756
| ELE-Aging Inspection | 8/15/2017 | 8/15/2017 | 8/15/2017 3:03:59 PM | | PASS |
|
|
Drove by and inspected
|
ELE13-02756
| Final | 8/15/2017 | 8/15/2017 | 8/15/2017 2:53:16 PM | P | PASS |
|
|
Listing and disconnecting means confirmed. Final ok
|
ELE16-03931
| Electrical Rough-In | 8/15/2017 | 8/15/2017 | 8/15/2017 2:45:12 PM | P | PASS |
|
|
units 301, 302, 304, 305, 307, 309 Phone #: ###-#### Inspection requested via web by Cathy Duchek Rooms noted in office rough in ok cover
|
ELE16-00580
| Electrical Rough-In | 8/15/2017 | 8/15/2017 | 8/15/2017 2:44:36 PM | P | PASS |
|
|
walls- 115 generator, 113 water-fire, 114 bikeparking, 214 storage, electrical 217 Phone #: ###-#### Inspection requested via web by Cathy Duchek Rooms noted walls only rough in ok cover
|
ELE17-02356
| Electrical Rough-In | 8/14/2017 | 8/15/2017 | 8/15/2017 1:02:22 PM | P | PASS |
|
|
Underground and potting Inspection Phone #: ###-#### Inspection requested via web by Louis Keller Back of garage removed and expose electrical needs attention. Underground and potting for light rough in ok cover
|
MIS17-00260
| ELE-Conference | 8/15/2017 | 8/15/2017 | 8/15/2017 12:20:41 PM | P | FAIL |
|
|
Complaint by other inspector of electrical work being done with out proper permit. Noticed open boxes in kitchen area and no cabinets set. No answer at door. Posted stop work order and asked to contact.
|
ELE17-01511
| Final | 8/14/2017 | 8/15/2017 | 8/15/2017 11:22:58 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Barbara Szurgot 110.3- Corridor receptacle outlet not working. 210.8( B)- All receptacle outlets 120 volt located with in 6' of a sink shall have GFCI protection. Back classroom with new sink. 314.20- Where boxes are mounted more than 1/4" from surface of wall a spark ring shall be installed. Bath outlets and others. 404.10- Corridor bath switch not mounted and wiring tied thru. Only electrician shall do work. Energy code- All areas shall have OCC sensors as noted on print. ELE14-02605 for sancuary and upstairs must also final for that work.
|
ELE17-01951
| Electrical Rough-In | 8/14/2017 | 8/15/2017 | 8/15/2017 10:11:10 AM | A | PASS |
|
|
Underground cover. Phone #: ###-#### Inspection requested via web by Buster Bowen North and east perimeter, from east central to west, and south end of football underground rough in ok cover
|
ELE17-00425
| Final | 8/15/2017 | 8/15/2017 | 8/15/2017 9:28:54 AM | A | PASS |
|
|
We hung 2 panels someone else took it from there. Phone #: ###-#### Inspection requested via web by Greg Idsinga Final ok
|
ELE17-02645
| Final | 8/15/2017 | 8/15/2017 | 8/15/2017 9:28:23 AM | A | PASS |
|
|
Please call Brad (###-####) ahead for access Phone #: ###-#### Inspection requested via web by Brad Girard Final ok
|
ELE17-02645
| Electrical Rough-In | 8/15/2017 | 8/15/2017 | 8/15/2017 9:28:09 AM | P | PASS |
|
|
Please call Brad (###-####) ahead for access Phone #: ###-#### Inspection requested via web by Brad Girard Add recessed cans, chandeliers, and couple receptacles. Clean ceiling areas, all seismic in place. Rough in ok cover
|
ELE17-01549
| Electrical Rough-In | 8/14/2017 | 8/15/2017 | 8/14/2017 2:49:00 PM | A | PASS |
|
|
Underground Phone #: ###-#### Inspection requested via web by Shawna Gates Underground front south of entrance rough in ok cover
|