Inspections for the day of: Tuesday, August 15, 2017.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE13-02756 ELE-Aging Inspection8/15/20178/15/20178/15/2017 3:03:59 PM PASS
Drove by and inspected
ELE13-02756 Final8/15/20178/15/20178/15/2017 2:53:16 PMPPASS
Listing and disconnecting means confirmed. Final ok
ELE16-03931 Electrical Rough-In8/15/20178/15/20178/15/2017 2:45:12 PMPPASS
units 301, 302, 304, 305, 307, 309 Phone #: ###-#### Inspection requested via web by Cathy Duchek
Rooms noted in office rough in ok cover
ELE16-00580 Electrical Rough-In8/15/20178/15/20178/15/2017 2:44:36 PMPPASS
walls- 115 generator, 113 water-fire, 114 bikeparking, 214 storage, electrical 217 Phone #: ###-#### Inspection requested via web by Cathy Duchek
Rooms noted walls only rough in ok cover
ELE17-02356 Electrical Rough-In8/14/20178/15/20178/15/2017 1:02:22 PMPPASS
Underground and potting Inspection Phone #: ###-#### Inspection requested via web by Louis Keller
Back of garage removed and expose electrical needs attention.
Underground and potting for light rough in ok cover
MIS17-00260 ELE-Conference8/15/20178/15/20178/15/2017 12:20:41 PMPFAIL
Complaint by other inspector of electrical work being done with out proper permit.
Noticed open boxes in kitchen area and no cabinets set.
No answer at door. Posted stop work order and asked to contact.
ELE17-01511 Final8/14/20178/15/20178/15/2017 11:22:58 AMAFAIL
Phone #: ###-#### Inspection requested via web by Barbara Szurgot
110.3- Corridor receptacle outlet not working.
210.8( B)- All receptacle outlets 120 volt located with in 6' of a sink shall have GFCI protection. Back classroom with new sink.
314.20- Where boxes are mounted more than 1/4" from surface of wall a spark ring shall be installed. Bath outlets and others.
404.10- Corridor bath switch not mounted and wiring tied thru. Only electrician shall do work.
Energy code- All areas shall have OCC sensors as noted on print.
ELE14-02605 for sancuary and upstairs must also final for that work.
ELE17-01951 Electrical Rough-In8/14/20178/15/20178/15/2017 10:11:10 AMAPASS
Underground cover. Phone #: ###-#### Inspection requested via web by Buster Bowen
North and east perimeter, from east central to west, and south end of football underground rough in ok cover
ELE17-00425 Final8/15/20178/15/20178/15/2017 9:28:54 AMAPASS
We hung 2 panels someone else took it from there. Phone #: ###-#### Inspection requested via web by Greg Idsinga Final ok
ELE17-02645 Final8/15/20178/15/20178/15/2017 9:28:23 AMAPASS
Please call Brad (###-####) ahead for access Phone #: ###-#### Inspection requested via web by Brad Girard
Final ok
ELE17-02645 Electrical Rough-In8/15/20178/15/20178/15/2017 9:28:09 AMPPASS
Please call Brad (###-####) ahead for access Phone #: ###-#### Inspection requested via web by Brad Girard
Add recessed cans, chandeliers, and couple receptacles. Clean ceiling areas, all seismic in place. Rough in ok cover
ELE17-01549 Electrical Rough-In8/14/20178/15/20178/14/2017 2:49:00 PMAPASS
Underground Phone #: ###-#### Inspection requested via web by Shawna Gates
Underground front south of entrance rough in ok cover