ELE18-01608
| Temporary Service | 8/15/2018 | 8/15/2018 | 8/15/2018 2:46:12 PM | P | FAIL |
|
|
please call Corey Phone #: ###-#### Inspection requested via web by Kevin Perez Temp service requires seperate permit
|
ELE18-02656
| Final | 8/14/2018 | 8/15/2018 | 8/15/2018 2:17:22 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Cortney Hopper Final ok
|
ELE18-02656
| Electrical Rough-In | 8/15/2018 | 8/15/2018 | 8/15/2018 2:14:34 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Cortney Hopper All wiring surface mounted for lighting. Receptacle fished in wall. Rough in ok
|
ELE18-00502
| Final | 8/13/2018 | 8/15/2018 | 8/15/2018 1:52:50 PM | P | PASS |
|
|
homeowner to be home Phone #: ###-#### Inspection requested via web by Kevin Koomler Final ok
|
ELE18-03068
| Electrical Rough-In | 8/15/2018 | 8/15/2018 | 8/15/2018 1:17:26 PM | P | PASS |
|
|
Garage code 1957e Phone #: ###-#### Inspection requested via web by Alan Lusk Rough in ok cover p/s u/g n ok
|
ELE18-02177
| Final | 8/15/2018 | 8/15/2018 | 8/15/2018 12:53:03 PM | P | FAIL |
|
|
Garage code 1957e Phone #: ###-#### Inspection requested via web by Alan Lusk 110.3- Areas not complete- garage receptacles not working, 1/2 of kitchen and pantry receptacles not working, disposal cord, hood hook up. 210.52(B)- Kitchen counter top receptacles, no point measured along wall line shall be more than 24" from a receptacle outlet. kitchen window wall 5'5" between receptacles. 314.25- All boxes shall have covers. Bathroom vanity lights level 1&2, Device cover level 1 brick wall and level 3 switch covers.
|
ELE18-03106
| Rough-In Permanent Service | 8/15/2018 | 8/15/2018 | 8/15/2018 11:18:10 AM | A | PASS |
|
|
2089899410....
Call John if any problems Inspection requested via web by John Harvey Service rough in only. No wiring in house yet, temp receptacles not in yet. p/s u/g n ok
|
ELE18-03096
| Final | 8/14/2018 | 8/15/2018 | 8/15/2018 10:55:15 AM | A | PASS |
|
|
Robert Phone #: ###-#### Final ok
|
ELE18-03096
| Electrical Rough-In | 8/15/2018 | 8/15/2018 | 8/15/2018 10:38:50 AM | P | PASS |
|
|
Robert Phone #: ###-#### Rough in ok
|
ELE18-03061
| Rough-In Permanent Service | 8/15/2018 | 8/15/2018 | 8/15/2018 10:38:01 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Bob Glenn Rough in ok cover
|
ELE18-02664
| Rough-In Permanent Service | 8/15/2018 | 8/15/2018 | 8/15/2018 10:14:37 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Bob Glenn Rough in ok cover p/s u/g n ok
|
ELE18-02479
| Electrical Rough-In | 8/15/2018 | 8/15/2018 | 8/15/2018 9:38:19 AM | A | PART |
|
|
Wall rough-in inspection for level 10 CH2M in One Cap building Contact Jon Novak Thank you Phone #: ###-#### Inspection requested via web by Tom Betty Hold on MFP wall and to west due to boxes behind new wall shall be abandoned prior to cover. Rest of walls rough in ok cover.
|
ELE17-04065
| Final | 8/14/2018 | 8/15/2018 | 8/14/2018 3:22:04 PM | A | PASS |
|
|
Danny is the contact Phone #: ###-#### Inspection requested via web by Buster Bowen Corrections complete. Final ok
|