MEC19-03653
| Pressure Test | 8/15/2019 | 8/15/2019 | 8/15/2019 4:05:57 PM | P | PASS |
|
|
pool heater , pressure test call Greg with any questions ###-#### Phone #: ###-#### Inspection requested via web by Greg Mendiola- 20lb gas pass underground- ok to backfill
|
MEC19-03653
| Final | 8/15/2019 | 8/15/2019 | 8/15/2019 4:05:56 PM | P | PASS |
|
|
pool heater , pressure test call Greg with any questions ###-#### Phone #: ###-#### Inspection requested via web by Greg Mendiola
|
MEC19-02370
| Final | 8/14/2019 | 8/15/2019 | 8/15/2019 3:41:25 PM | P | FAIL |
|
|
Garage code 6074 Phone #: ###-#### Inspection requested via web by Jon VanderStelt 1- need to uv protect line set outside 2- single all flue on water heater needs 6" clearance to combustibles 3- need to fill out all totals on air balance form for tests done and design
|
MEC19-03647
| Final | 8/15/2019 | 8/15/2019 | 8/15/2019 3:15:40 PM | P | NR |
|
|
later in afternoon is better. Phone #: ###-#### Inspection requested via web by Floyd Floyd Peek- talked to Max about this
|
MEC19-03482
| Final | 8/12/2019 | 8/15/2019 | 8/15/2019 2:56:47 PM | P | PASS |
|
|
Field Super: Chad Robertson Phone #: ###-#### Inspection requested via web by Lisa Whitney- furnace in crawl coil a/c reduct crawl co ok
|
MEC19-03534
| Final | 8/14/2019 | 8/15/2019 | 8/15/2019 2:36:09 PM | P | PART |
|
|
INSTALLER TRAVIS ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- furnace a/c coil co ok- 5lb flue test pass- need to have electrical permit issued for breaker change in panel to final this permit out
|
MEC19-03585
| Final | 8/14/2019 | 8/15/2019 | 8/15/2019 2:07:15 PM | P | PASS |
|
|
Please call Craig on your way - ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks
|
MEC19-03636
| Pressure Test | 8/14/2019 | 8/15/2019 | 8/15/2019 1:19:56 PM | P | CANC |
|
|
Phone #: ###-#### Inspection requested via web by Joseph Profitt
|
MEC19-03636
| Rough-in | 8/14/2019 | 8/15/2019 | 8/15/2019 1:19:46 PM | P | CANC |
|
|
Phone #: ###-#### Inspection requested via web by Joseph Profitt
|
MEC19-03641
| Pressure Test | 8/14/2019 | 8/15/2019 | 8/15/2019 1:19:36 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Joseph Profitt- poly pipe needs anodised riser both ends and approved manufacture flex connector on outside of mobile home- went over onsite with installer and talked to Joeseph by phone
|
MEC19-03641
| Rough-in | 8/14/2019 | 8/15/2019 | 8/15/2019 1:18:02 PM | P | CANC |
|
|
Phone #: ###-#### Inspection requested via web by Joseph Profitt
|
MEC19-03638
| Pressure Test | 8/14/2019 | 8/15/2019 | 8/15/2019 1:17:53 PM | P | CANC |
|
|
Phone #: ###-#### Inspection requested via web by Joseph Profitt
|
MEC19-03638
| Rough-in | 8/14/2019 | 8/15/2019 | 8/15/2019 1:17:41 PM | P | CANC |
|
|
Phone #: ###-#### Inspection requested via web by Joseph Profitt
|
MEC19-03639
| Pressure Test | 8/14/2019 | 8/15/2019 | 8/15/2019 1:17:29 PM | P | CANC |
|
|
Phone #: ###-#### Inspection requested via web by Joseph Profitt
|
MEC19-03639
| Rough-in | 8/14/2019 | 8/15/2019 | 8/15/2019 1:17:11 PM | P | CANC |
|
|
Phone #: ###-#### Inspection requested via web by Joseph Profitt
|
MEC19-03640
| Pressure Test | 8/14/2019 | 8/15/2019 | 8/15/2019 1:16:57 PM | P | CANC |
|
|
Phone #: ###-#### Inspection requested via web by Joseph Profitt
|
MEC19-03640
| Rough-in | 8/14/2019 | 8/15/2019 | 8/15/2019 1:16:38 PM | P | CANC |
|
|
Phone #: ###-#### Inspection requested via web by Joseph Profitt
|
MEC19-03637
| Pressure Test | 8/14/2019 | 8/15/2019 | 8/15/2019 1:16:26 PM | P | CANC |
|
|
Phone #: ###-#### Inspection requested via web by Joseph Profitt- poly pipe needs anodised riser both ends and approved mobile home flex connector installed outside of mobile home- poly pipe can not be exposed to outdoors
|
MEC19-03637
| Rough-in | 8/14/2019 | 8/15/2019 | 8/15/2019 1:14:48 PM | P | CANC |
|
|
Phone #: ###-#### Inspection requested via web by Joseph Profitt
|
MEC19-03613
| Final | 8/14/2019 | 8/15/2019 | 8/15/2019 12:36:02 PM | P | PART |
|
|
Please call Josh on your way - ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks- a/c coil ok- need to upsize breaker in panel to low for rating now minimum 31.9 amps and all breakers in panel are 30- will need electrical permit issued to final out
|
MEC19-03277
| Final | 8/13/2019 | 8/15/2019 | 8/15/2019 12:08:00 PM | P | CANC |
|
|
This is a Flue Pressure and Final Inspect. Please meet our installer at home at 1:30 PM. Contact for Right Now is Mary ###-####
Phone #: ###-#### >> Inspection requested via web by Mary LaFayette Inspection cancelled from web by: Mary LaFayette
|
MEC19-03516
| Rough-in | 8/14/2019 | 8/15/2019 | 8/15/2019 11:30:17 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Terek Worley 1- need ladder provided by contractor to access furnace/coil on attic 2- need to seal fresh filter can in master closet and 6" fresh air needs to go to R/A plenum near furnace not register can 3- whos doing firepace hasnt been installed yet?
left correction notice front entry window
|
MEC19-03516
| Pressure Test | 8/14/2019 | 8/15/2019 | 8/15/2019 11:27:32 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Terek Worley- 20lb gas pass tagged meter location
|
MEC19-03514
| Rough-in | 8/14/2019 | 8/15/2019 | 8/15/2019 11:25:50 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Terek Worley- 1- need ladder provided by contractor to access furnace/coil on attic 2- 6" fresh air can not be tied into R/A can has to be tied into R/A plenum near furnace and seal filter box in closet 3- framing needs completed around supply duct 2nd floor 4- bath fan for master bath 1st floor pinched off where goes thru joist 5- upper and lower combustion air for laundry room needs to commence with 12 inches of floor and ceiling
Left correction notice front entry window
|
MEC19-03514
| Pressure Test | 8/14/2019 | 8/15/2019 | 8/15/2019 11:21:06 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Terek Worley- 20lb gas pass tagged meter location
|
MEC19-02747
| Final | 8/15/2019 | 8/15/2019 | 8/15/2019 10:44:34 AM | P | CANC |
|
|
CALL AHEAD, WILL BE HOME AFTER 2pm Phone #: ###-#### >> Inspection requested via web by Monica Lindsay Inspection cancelled from web by: Monica Lindsay
|
MEC19-02512
| Rough-in | 8/13/2019 | 8/15/2019 | 8/15/2019 10:39:09 AM | A | PART |
|
|
Francisco is the contact Phone #: ###-#### Inspection requested via web by stan lillquist- Rtu at grid line 3 ducting and seal ok ok to insulate- rtu bewteen grid 4 and 5 ducting and seal ok ok to insulate- studio area seal on duct ok ok to insulate- recall in when other rtu ducting is completed- went over with Francisco onsite
|
MEC19-02181
| Final | 8/14/2019 | 8/15/2019 | 8/15/2019 10:12:47 AM | A | PART |
|
|
Jake is your contact Phone #: ###-#### Inspection requested via web by Kim Adams- need to label f/s dampers on grid- need to roof in all penetrations on roof- secondary drains from coil can not tie into primary furnace drains- air balance still needs completed- temp occupamcy ok this permit only- other mech contractor inspection still needs on gas piping called in
|
MEC19-02776
| Final | 8/15/2019 | 8/15/2019 | 8/15/2019 10:09:55 AM | A | PART |
|
|
need to secure all gas piping to supports on roof- secondary drsins on coil can not tie into primary drains from furnace- need to have gas piping penetration thru roof roofed in-
|
MEC19-02773
| Final | 8/14/2019 | 8/15/2019 | 8/15/2019 9:22:16 AM | A | PASS |
|
|
Please call Gus prior to inspection. ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette- a/c coil co ok
|
MEC19-03383
| Rough-in | 8/14/2019 | 8/15/2019 | 8/15/2019 8:33:58 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves- R/I ok
|
MEC19-03603
| Rough-in | 8/14/2019 | 8/15/2019 | 8/15/2019 8:20:01 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Joe Taylor- R/I ok- equipment not set check at final
|
MEC19-00027
| Mec-Aging Inspection | 8/15/2019 | 8/15/2019 | 8/15/2019 7:46:32 AM | | FAIL |
|
|
contractor needs to schedule inspection if work has been done- permit will expire next aging if no activity
|
MEC19-00049
| Mec-Aging Inspection | 8/15/2019 | 8/15/2019 | 8/15/2019 7:45:20 AM | | FAIL |
|
|
contractor needs to reschedule inspection no one home last time- permit will expire next aging if no activity
|