Inspections for the day of: Thursday, August 15, 2019.
Number of inspections: 34
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC19-03653 Pressure Test8/15/20198/15/20198/15/2019 4:05:57 PMPPASS
pool heater , pressure test call Greg with any questions ###-#### Phone #: ###-#### Inspection requested via web by Greg Mendiola- 20lb gas pass underground- ok to backfill
MEC19-03653 Final8/15/20198/15/20198/15/2019 4:05:56 PMPPASS
pool heater , pressure test call Greg with any questions ###-#### Phone #: ###-#### Inspection requested via web by Greg Mendiola
MEC19-02370 Final8/14/20198/15/20198/15/2019 3:41:25 PMPFAIL
Garage code 6074 Phone #: ###-#### Inspection requested via web by Jon VanderStelt
1- need to uv protect line set outside
2- single all flue on water heater needs 6" clearance to combustibles
3- need to fill out all totals on air balance form for tests done and design
MEC19-03647 Final8/15/20198/15/20198/15/2019 3:15:40 PMPNR
later in afternoon is better. Phone #: ###-#### Inspection requested via web by Floyd Floyd Peek- talked to Max about this
MEC19-03482 Final8/12/20198/15/20198/15/2019 2:56:47 PMPPASS
Field Super: Chad Robertson Phone #: ###-#### Inspection requested via web by Lisa Whitney- furnace in crawl coil a/c reduct crawl co ok
MEC19-03534 Final8/14/20198/15/20198/15/2019 2:36:09 PMPPART
INSTALLER TRAVIS ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- furnace a/c coil co ok- 5lb flue test pass- need to have electrical permit issued for breaker change in panel to final this permit out
MEC19-03585 Final8/14/20198/15/20198/15/2019 2:07:15 PMPPASS
Please call Craig on your way - ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks
MEC19-03636 Pressure Test8/14/20198/15/20198/15/2019 1:19:56 PMPCANC
Phone #: ###-#### Inspection requested via web by Joseph Profitt
MEC19-03636 Rough-in8/14/20198/15/20198/15/2019 1:19:46 PMPCANC
Phone #: ###-#### Inspection requested via web by Joseph Profitt
MEC19-03641 Pressure Test8/14/20198/15/20198/15/2019 1:19:36 PMPFAIL
Phone #: ###-#### Inspection requested via web by Joseph Profitt- poly pipe needs anodised riser both ends and approved manufacture flex connector on outside of mobile home- went over onsite with installer and talked to Joeseph by phone
MEC19-03641 Rough-in8/14/20198/15/20198/15/2019 1:18:02 PMPCANC
Phone #: ###-#### Inspection requested via web by Joseph Profitt
MEC19-03638 Pressure Test8/14/20198/15/20198/15/2019 1:17:53 PMPCANC
Phone #: ###-#### Inspection requested via web by Joseph Profitt
MEC19-03638 Rough-in8/14/20198/15/20198/15/2019 1:17:41 PMPCANC
Phone #: ###-#### Inspection requested via web by Joseph Profitt
MEC19-03639 Pressure Test8/14/20198/15/20198/15/2019 1:17:29 PMPCANC
Phone #: ###-#### Inspection requested via web by Joseph Profitt
MEC19-03639 Rough-in8/14/20198/15/20198/15/2019 1:17:11 PMPCANC
Phone #: ###-#### Inspection requested via web by Joseph Profitt
MEC19-03640 Pressure Test8/14/20198/15/20198/15/2019 1:16:57 PMPCANC
Phone #: ###-#### Inspection requested via web by Joseph Profitt
MEC19-03640 Rough-in8/14/20198/15/20198/15/2019 1:16:38 PMPCANC
Phone #: ###-#### Inspection requested via web by Joseph Profitt
MEC19-03637 Pressure Test8/14/20198/15/20198/15/2019 1:16:26 PMPCANC
Phone #: ###-#### Inspection requested via web by Joseph Profitt- poly pipe needs anodised riser both ends and approved mobile home flex connector installed outside of mobile home- poly pipe can not be exposed to outdoors
MEC19-03637 Rough-in8/14/20198/15/20198/15/2019 1:14:48 PMPCANC
Phone #: ###-#### Inspection requested via web by Joseph Profitt
MEC19-03613 Final8/14/20198/15/20198/15/2019 12:36:02 PMPPART
Please call Josh on your way - ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks- a/c coil ok- need to upsize breaker in panel to low for rating now minimum 31.9 amps and all breakers in panel are 30- will need electrical permit issued to final out
MEC19-03277 Final8/13/20198/15/20198/15/2019 12:08:00 PMPCANC
This is a Flue Pressure and Final Inspect. Please meet our installer
at home at 1:30 PM. Contact for Right Now is Mary ###-####

Phone #: ###-#### >> Inspection requested via web by Mary LaFayette Inspection cancelled from web by: Mary LaFayette
MEC19-03516 Rough-in8/14/20198/15/20198/15/2019 11:30:17 AMAFAIL
Phone #: ###-#### Inspection requested via web by Terek Worley
1- need ladder provided by contractor to access furnace/coil on attic
2- need to seal fresh filter can in master closet and 6" fresh air needs to go to R/A plenum near furnace not register can
3- whos doing firepace hasnt been installed yet?

left correction notice front entry window
MEC19-03516 Pressure Test8/14/20198/15/20198/15/2019 11:27:32 AMAPASS
Phone #: ###-#### Inspection requested via web by Terek Worley- 20lb gas pass tagged meter location
MEC19-03514 Rough-in8/14/20198/15/20198/15/2019 11:25:50 AMAFAIL
Phone #: ###-#### Inspection requested via web by Terek Worley-
1- need ladder provided by contractor to access furnace/coil on attic
2- 6" fresh air can not be tied into R/A can has to be tied into R/A plenum near furnace and seal filter box in closet
3- framing needs completed around supply duct 2nd floor
4- bath fan for master bath 1st floor pinched off where goes thru joist
5- upper and lower combustion air for laundry room needs to commence with 12 inches of floor and ceiling

Left correction notice front entry window
MEC19-03514 Pressure Test8/14/20198/15/20198/15/2019 11:21:06 AMAPASS
Phone #: ###-#### Inspection requested via web by Terek Worley- 20lb gas pass tagged meter location
MEC19-02747 Final8/15/20198/15/20198/15/2019 10:44:34 AMPCANC
CALL AHEAD, WILL BE HOME AFTER 2pm Phone #: ###-#### >> Inspection requested via web by Monica Lindsay Inspection cancelled from web by: Monica Lindsay
MEC19-02512 Rough-in8/13/20198/15/20198/15/2019 10:39:09 AMAPART
Francisco is the contact Phone #: ###-#### Inspection requested via web by stan lillquist- Rtu at grid line 3 ducting and seal ok ok to insulate- rtu bewteen grid 4 and 5 ducting and seal ok ok to insulate- studio area seal on duct ok ok to insulate- recall in when other rtu ducting is completed- went over with Francisco onsite
MEC19-02181 Final8/14/20198/15/20198/15/2019 10:12:47 AMAPART
Jake is your contact Phone #: ###-#### Inspection requested via web by Kim Adams- need to label f/s dampers on grid- need to roof in all penetrations on roof- secondary drains from coil can not tie into primary furnace drains- air balance still needs completed- temp occupamcy ok this permit only- other mech contractor inspection still needs on gas piping called in
MEC19-02776 Final8/15/20198/15/20198/15/2019 10:09:55 AMAPART
need to secure all gas piping to supports on roof- secondary drsins on coil can not tie into primary drains from furnace- need to have gas piping penetration thru roof roofed in-
MEC19-02773 Final8/14/20198/15/20198/15/2019 9:22:16 AMAPASS
Please call Gus prior to inspection. ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette- a/c coil co ok
MEC19-03383 Rough-in8/14/20198/15/20198/15/2019 8:33:58 AMAPASS
Phone #: ###-#### Inspection requested via web by Gary Reeves- R/I ok
MEC19-03603 Rough-in8/14/20198/15/20198/15/2019 8:20:01 AMAPASS
Phone #: ###-#### Inspection requested via web by Joe Taylor- R/I ok- equipment not set check at final
MEC19-00027 Mec-Aging Inspection8/15/20198/15/20198/15/2019 7:46:32 AM FAIL
contractor needs to schedule inspection if work has been done- permit will expire next aging if no activity
MEC19-00049 Mec-Aging Inspection8/15/20198/15/20198/15/2019 7:45:20 AM FAIL
contractor needs to reschedule inspection no one home last time- permit will expire next aging if no activity