Inspections for the day of: Friday, August 16, 2002.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE02-00008 Final8/15/20028/16/20028/16/2002 12:00:00 AMAPASS
RON ###-#### SITE LIGHTING PERMIT WAS TAKEN OUT (SUPERIOR ELE TOOK IT OUT) IF ANY PROBLEMS PLEASE CANTACT RON ok 8/15/2002 5:01:34 PM
ELE02-02098 Rough-In Permanent Service8/15/20028/16/20028/16/2002 12:00:00 AMANH
Scheduled by a contractor via Hello! on 08/15/2002 at 13:53:20. Contact: . notice posted 8/16/2002 10:40:29 AM
ELE02-02537 Rough-In Permanent Service8/15/20028/16/20028/16/2002 12:00:00 AMAPASS
###-#### detached garage garage and u/g ok 8/16/2002 2:10:58 PM
ELE02-00623 Electrical Rough-In8/15/20028/16/20028/16/2002 12:00:00 AMAPART
###-#### DUAINE no r/i conference ok only 8/16/2002 11:16:46 AM
ELE02-01424 Final8/15/20028/16/20028/16/2002 12:00:00 AMANR
Scheduled by a contractor via Hello! on 08/15/2002 at 16:39:34. Contact: ###-####. 8/16/2002 10:39:59 AM no acces disconnects locked and same corrections as 805 s shoshone talked with contractor 8/16/2002 12:30:35 PM
ELE02-01917 Electrical Rough-In8/16/20028/16/20028/16/2002 12:00:00 AMAFAIL
cor. posted met with contractor and PLass 110.3(B) max 15 amp feed too fan coil unit, 386.22 wire fill shall not exceed what raceway is designed for, 300.16 shall provide a terminal fitting for abrasion where cable exits raceway
ELE02-02374 Final8/16/20028/16/20028/16/2002 12:00:00 AMPPASS
ok
ELE02-02374 Electrical Rough-In8/16/20028/16/20028/16/2002 12:00:00 AMPCANC
###-#### wayne or jim no r/i see added final
8/16/2002 6:22:21 PM
ELE02-01900 Electrical Rough-In8/16/20028/16/20028/16/2002 12:00:00 AMPPART
Scheduled by a contractor via Hello! on 08/16/2002 at 08:04:15. Contact: . u/g to garage ok 8/16/2002 3:13:39 PM
ELE02-02559 Rough-In Permanent Service8/16/20028/16/20028/16/2002 12:00:00 AMPPART
###-#### dan master bath only ok for r/i 8/16/2002 3:50:35 PM
ELE02-02556 Electrical Rough-In8/16/20028/16/20028/16/2002 12:00:00 AMPPART
Scheduled by a contractor via Hello! on 08/16/2002 at 08:17:58. Contact: ###-####. part walls and ceiling N W bed rm 8/16/2002 4:29:10 PM
ELE02-02480 Permanent Service8/16/20028/16/20028/16/2002 12:00:00 AMPPASS
###-#### p/s only Romar did not wire new addition

p/s o/h rec ok 8/16/2002 5:20:41 PM
ELE02-02197 Electrical Rough-In8/15/20028/16/20028/16/2002 12:00:00 AMPFAIL
Scheduled by a contractor via Hello! on 08/15/2002 at 16:20:02. Contact: ###-####. cor. posted met with owner250.8,110.3 (B) breakers, 300.5, 250.52(C), 352.46and 300.4(F), 110.14(B) insulation for splices jbox, 110.26 cleraence in front of panels in garage 8/16/2002 6:53:00 PM