Inspections for the day of: Tuesday, August 16, 2016.
Number of inspections: 16
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJames Ady
TitleELE-INSPECTOR
Phone #914-4683
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE12-02709 ELE-Aging Inspection8/16/20168/16/20168/23/2016 1:40:14 PM DONE
Pat will call ASAP
ELE16-02660 Rough-In Permanent Service8/16/20168/16/20168/16/2016 4:56:23 PMPFAIL
Phone #: ###-#### Inspection requested via web by Jason Wicks 210.52 B 2 The 2 or more small appliance circuits shall have no other recepts. (back patio WP) 334.30 NM cable shall be supported every4.5ft. (8-3 to range) 320.23 A Cables within 6ft from attic shall be protected from damage. 300.4 A 1. Cables through bored hole less than 1.25in from face of stud shall have nail plate. (stair half wall coner, SW Bed front corner, up hall bath,) Inspection point installed on ufer
ELE15-03729 Electrical Rough-In8/15/20168/16/20168/16/2016 3:05:59 PMPPASS
Units 11-18
Phone #: ###-#### Inspection requested via web by Kerri Hamilton Rooms 11-20 rough in ok to cover
ELE16-02664 Electrical Rough-In8/16/20168/16/20168/16/2016 2:28:23 PMPPASS
Phone #: ###-#### Inspection requested via web by John VanZandt Kitchen remodel ok to cover
ELE16-01537 Permanent Service8/16/20168/16/20168/16/2016 1:26:58 PMPPASS
Phone #: ###-#### Inspection requested via web by mike brown p/s u/g n ok
ELE16-02140 Electrical Rough-In8/16/20168/16/20168/16/2016 12:32:18 PMPPASS
Ceiling Inspection. Contact Jon Novak.
Thank you, Phone #: ###-#### Inspection requested via web by Cathy Duchek Ceilings ok to cover
ELE16-02628 Permanent Service8/16/20168/16/20168/16/2016 11:43:49 AMPPASS
Tom Phone #: ###-#### p/s u/g n ok
ELE16-01590 Electrical Rough-In8/15/20168/16/20168/16/2016 10:58:38 AMAPASS
Phone #: ###-#### Inspection requested via web by Mark Estep 3rd car bay only Rough in ok
ELE16-02168 Final8/15/20168/16/20168/16/2016 10:32:29 AMAPASS
Phone #: ###-#### Inspection requested via web by Spencer McLean cell tower service final ok
ELE16-01826 Electrical Rough-In8/15/20168/16/20168/16/2016 10:10:32 AMACANC
Inspection on floor heat. Phone #: ###-#### >> Inspection requested via web by Rhonda Yoast Inspection cancelled from web by: Rhonda Yoast
ELE16-02633 Conference8/15/20168/16/20168/16/2016 10:09:13 AMACANC
Call Randy at ###-#### to schedule meet Phone #: ###-#### Inspection requested via web by Randy Fletcher Already talked to Bob. Didnt need a conference
ELE16-02646 Permanent Service8/15/20168/16/20168/16/2016 10:02:18 AMAPASS
Jason Phone #: ###-#### p/s o/h rec ok
ELE16-02656 Electrical Rough-In8/15/20168/16/20168/16/2016 9:50:20 AMAPASS
Bonding for: (4) EQ corners, (2) autocover, (1) water( in skimmer), (1) steel/equipment
UG for: (3) LV pool lights, (1) autocover motor Phone #: ###-#### Inspection requested via web by Lars Johnson Pool bond and underground ok to cover
ESC16-00471 Site Final8/16/20168/16/20168/16/2016 9:35:18 AMPPASS
site final ok
ELE16-01859 Final8/15/20168/16/20168/16/2016 9:33:17 AMAPASS
Garage code 2474 Phone #: ###-#### Inspection requested via web by Chris Berthelot Final ok
ELE16-00431 Final8/15/20168/16/20168/16/2016 9:33:16 AMAPART
final inspection building O on 3rd and 4th floor Phone #: ###-#### Inspection requested via web by Bob Stephens 3rd and 4th floor only Final ok