ELE15-02087
| ELE-Aging Inspection | 8/16/2019 | 8/16/2019 | 8/22/2019 4:05:39 PM | | FAIL |
|
|
slow moving job. Waiting on contractor
|
ELE19-03069
| Electrical Rough-In | 8/16/2019 | 8/16/2019 | 8/16/2019 3:12:24 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Ashley Rasmussen Listing confirmed rough in ok
|
ELE19-00602
| Electrical Rough-In | 8/16/2019 | 8/16/2019 | 8/16/2019 2:49:25 PM | P | PASS |
|
|
Garage Stairwell cover. Tyson is the contact. Phone #: ###-#### Inspection requested via web by Buster Bowen S.E. stair well level 2 walls rough in ok cover
|
ELE18-01929
| Final | 8/15/2019 | 8/16/2019 | 8/16/2019 2:15:25 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Alan Lusk Final ok
|
ELE19-01861
| Final | 8/16/2019 | 8/16/2019 | 8/16/2019 1:34:09 PM | P | PASS |
|
|
Please call 30 minutes before so Troy can meet you there Phone #: ###-#### Inspection requested via web by Don Conley Final ok
|
ELE19-03008
| Electrical Rough-In | 8/15/2019 | 8/16/2019 | 8/16/2019 1:07:15 PM | A | PASS |
|
|
Please call Josh at ###-#### with 1/2 hour notice to meet you there.
Thanks Phone #: ###-#### Inspection requested via web by Barbara Szurgot Kitchen, dining, utility rough in ok cover.
|
ELE19-02028
| Electrical Rough-In | 8/16/2019 | 8/16/2019 | 8/16/2019 12:21:14 PM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Kerri Hamilton 330.30- MC shall be sucred with in 12" of a box. jumpers between boxes and fixture whip exceeding 6'
|
ELE19-00843
| Final | 8/15/2019 | 8/16/2019 | 8/16/2019 11:54:05 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Daniel Dow 210.8- All receptacles serving kitchen counter top areas shall have GFCI protection. Left of sink. 314.17- Where NM cable enters boxes sheathing shall enter box a minimum of 1/4". Island. Where NM cable enters a metal enclosure abrasion protection shall be provided. AC disconnect. 334.12- NM cable shall not be installed where subject to damage. Island, need conduit protection. 356.30- Non metallic flex shall be secured with in 12" of enclosure. AC whip. 406.5- Receptacles shall be secured to boxes. 1 rt of fireplace and basement family room. 406.9- Outdoor covers shall be extra duty rated. 408.4- Circuit directory shall be complete. 440.6- AC fuse shall not exceed value on name plate. 40 installed 35 max.
|
ELE19-02960
| Rough-In Permanent Service | 8/15/2019 | 8/16/2019 | 8/16/2019 10:31:46 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Alan Lusk Rough in ok cover p/s u/g n ok
|
ELE19-03049
| Temporary Service | 8/15/2019 | 8/16/2019 | 8/16/2019 9:45:36 AM | A | PASS |
|
|
New temp pole is installed in SW corner of lot. Phone #: ###-#### Inspection requested via web by Tod Lane t/s o/h n ok
|
ELE19-03018
| Rough-In Permanent Service | 8/15/2019 | 8/16/2019 | 8/16/2019 9:31:35 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Darryn Coburn Rough in ok cover p/s u/g n ok
|
ELE19-03058
| Temporary Service | 8/15/2019 | 8/16/2019 | 8/16/2019 8:54:18 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by David Nelson t/s u/g n ok
|
ELE19-02555
| Electrical Rough-In | 8/15/2019 | 8/16/2019 | 8/16/2019 8:35:03 AM | A | PASS |
|
|
Grid Inspection please Phone #: ###-#### Inspection requested via web by Winters LLC Grid rough in ok cover
|