ELE09-01258
| Conference | 8/17/2009 | 8/17/2009 | 8/17/2009 4:16:32 PM | P | DONE |
|
|
jack Phone #: ###-#### met contractor, talked about wiring behind foam insulation, open walls and bringing existing walls up to code, said that if no walls are worked on, then don't have to add receptacles, but suggested it would be better to do, and that bedroom still required afci protection anyway
|
ESC09-00180
| General Inspection | 8/17/2009 | 8/17/2009 | 8/17/2009 3:57:54 PM | P | PART |
|
|
had a conference, came in from front, didn't see sign, will go back in 2-3 days and check for rest
|
ELE09-01491
| Electrical Rough-In | 8/17/2009 | 8/17/2009 | 8/17/2009 3:40:44 PM | P | PASS |
|
|
Brian Phone #: ###-#### walls only ok to cover, no esc this project
|
ESC09-00022
| General Inspection | 8/17/2009 | 8/17/2009 | 8/17/2009 3:16:08 PM | P | PASS |
|
|
looked ok
|
ESC09-00394
| General Inspection | 8/17/2009 | 8/17/2009 | 8/17/2009 3:15:26 PM | P | PASS |
|
|
looked ok
|
ESC09-00432
| General Inspection | 8/17/2009 | 8/17/2009 | 8/17/2009 3:14:44 PM | P | PASS |
|
|
looked ok
|
ELE09-01108
| Electrical Rough-In | 8/17/2009 | 8/17/2009 | 8/17/2009 3:11:04 PM | P | FAIL |
|
|
Underground PVC - Contact: Dave Baugh Phone #: ###-#### Internet Inspection Request from: Melissa Kaae met contractor, correction notice, NEC 300.5 u/g raceways shall be minimum 24" deep under drive areas, no esc this project
|
ELE09-01506
| Temporary Service | 8/17/2009 | 8/17/2009 | 8/17/2009 2:35:12 PM | P | PASS |
|
|
Pat Phone #: ###-#### t/s u/g n ok, called contractor
|
ELE09-01486
| Electrical Rough-In | 8/13/2009 | 8/17/2009 | 8/17/2009 2:13:14 PM | P | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Dan Mitchell ric ok, no esc this project
|
ELE09-01486
| Final | 8/17/2009 | 8/17/2009 | 8/17/2009 2:13:02 PM | P | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Dan Mitchell ok to final, no esc this project
|
ELE09-01329
| Electrical Rough-In | 8/17/2009 | 8/17/2009 | 8/17/2009 1:19:05 PM | P | PART |
|
|
sw ceiling and recepts. Phone #: ###-#### Internet Inspection Request from: Jim Williams ok to cover ceiling sw corner area building onlly, owners moved into area over weekend, could only spot check receptacle because of furnishings, did not sign any occupancy cards
|
ELE09-01243
| Permanent Service | 8/17/2009 | 8/17/2009 | 8/17/2009 12:29:28 PM | P | PASS |
|
|
Darren Phone #: ###-#### p/s u/g n ok
|
ELE09-01489
| Rough-In Permanent Service | 8/14/2009 | 8/17/2009 | 8/17/2009 9:47:13 AM | A | PASS |
|
|
call first Phone #: ###-#### Internet Inspection Request from: PAT MILLER ric ok, p/s o/h rec ok, no esc this project
|
ELE09-00779
| ELE-Aging Inspection | 8/17/2009 | 8/17/2009 | 8/17/2009 8:57:00 AM | | DONE |
|
|
looked at signs, see final
|
ELE09-00779
| Final | 8/17/2009 | 8/17/2009 | 8/17/2009 8:56:39 AM | A | PASS |
|
|
looked at signs, ok to final
|
ESC09-00231
| General Inspection | 8/17/2009 | 8/17/2009 | 8/17/2009 8:47:15 AM | A | PASS |
|
|
looked ok, see site final
|
ESC09-00231
| Site Final | 8/17/2009 | 8/17/2009 | 8/17/2009 8:46:39 AM | A | PASS |
|
|
ok to final, work and planting done
|
ELE08-00734
| Final | 8/14/2009 | 8/17/2009 | 8/17/2009 8:43:04 AM | A | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Alan Lusk ok to final, no esc this project
|
ELE09-01491
| Electrical Rough-In | 8/14/2009 | 8/17/2009 | 8/17/2009 8:11:59 AM | A | NR |
|
|
bryan Phone #: ###-#### talked to contractor, he wants to recall for pm inspection, he ran out of time last week and needs more material before inspection, no esc this project
|