ELE12-00936
| ELE-Aging Inspection | 8/17/2016 | 8/17/2016 | 8/25/2016 2:49:24 PM | | PASS |
|
|
Waiting on contractor
|
ELE16-02600
| Electrical Rough-In | 8/17/2016 | 8/17/2016 | 8/18/2016 8:19:28 AM | P | DONE |
|
|
2nd Floor Rough Phone #: ###-#### Inspection requested via web by Buster Bowen discussed 210.60 clarification on code reference. Conference only As per Daryl Degrange the required outlets shall follow 210.52 and the minimum number of receptacles is not permitted to be reduced and should be determined by assuming the furniture is not in place.
|
MIS16-00257
| ELE-Conference | 8/17/2016 | 8/17/2016 | 8/17/2016 4:27:59 PM | P | CANC |
|
|
Kevin-- Please call before** Kevin knows that Eric created MIS***Per Eric Strole- extra plumbing, mechanical and electrical work being done without a permit Phone #: ###-#### reschedule for next day
|
ELE16-02654
| Electrical Rough-In | 8/16/2016 | 8/17/2016 | 8/17/2016 4:27:58 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by kendall bender level 2 prep room and serving room Walls only. Panel and lighting by others.
|
ELE16-01838
| Electrical Rough-In | 8/16/2016 | 8/17/2016 | 8/17/2016 3:28:44 PM | P | PASS |
|
|
Level 5 stack 1 headquarters , Lab walls. Call John Phone #: ###-#### Inspection requested via web by Brandon Robinson area as noted wall roughin ok
|
ELE15-03901
| Electrical Rough-In | 8/17/2016 | 8/17/2016 | 8/17/2016 2:58:28 PM | P | PASS |
|
|
Call Rafael for inspection of office furniture on 8th floor. Phone #: ###-#### Inspection requested via web by Rafael Castillo furniture ok as noted on contractor prints.
|
ELE15-00495
| Electrical Rough-In | 8/17/2016 | 8/17/2016 | 8/17/2016 2:57:45 PM | P | PASS |
|
|
Wall rough in Stair 5 Floors 5,4,3 possibly 2. Contact is Eric Gibson ###-####. Phone #: ###-#### Inspection requested via web by Toby Groves core and shell stairwell number 5 floors 2-5 roughin ok to cover
|
ELE16-00089
| Electrical Rough-In | 8/17/2016 | 8/17/2016 | 8/17/2016 2:56:32 PM | A | PASS |
|
|
Rough-in inspection of walls on 4th and 5th floor around stairwell 5. Call Bob for inspection. Phone #: ###-#### Inspection requested via web by Rafael Castillo areas as noted plus elevator walls. Fixture on drop cloud ceiling shall have access to splice points and shall provide proof ceiling system is rated for weight.
|
ELE16-01946
| Electrical Rough-In | 8/16/2016 | 8/17/2016 | 8/17/2016 10:46:58 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Kerri Hamilton West offices and a few SW offices ok for cover as noted on contractor print.
|
ELE16-00983
| Final | 8/16/2016 | 8/17/2016 | 8/17/2016 10:08:39 AM | A | NR |
|
|
Michael (Betty''s son) Phone #: ###-#### Main service ok, garage wiring yet to be done. Owner to add garage to existing permit. Notified homeowner about this process.
|
ELE16-00983
| ELE-Request for Extension | 8/17/2016 | 8/17/2016 | 8/17/2016 10:06:50 AM | P | PASS |
|
|
Michael (Betty''s son) Phone #: ###-#### Existing garage burned. New panel in garage to be wired in the future. Underground ok
|
ELE16-02626
| Electrical Rough-In | 8/16/2016 | 8/17/2016 | 8/17/2016 9:43:47 AM | A | FAIL |
|
|
key in lock box by front entrance. code is 2173 Phone #: ###-#### Inspection requested via web by Paula Gratiot Failed for the following- 210.52 dining outlet needs added in open wall. 314.23(B)(1) replace boxes in multiple locations that have screws driven through the box for support. 210.11(C)(3) Walls are open in up bath, need to update 20a GFI circuit supplying vanity. 4. 210.52 outlet needs added to left of sliding door upstairs, over 6'.
|
ELE16-01107
| Final | 8/16/2016 | 8/17/2016 | 8/17/2016 9:01:36 AM | A | PASS |
|
|
This is a final inspection on a pool. The owner is Joe Illingworth and his number is ###-####. Phone #: ###-#### Inspection requested via web by Warren Fry Final ok
|